Two new algorithms for tracking arterial parameters in nonstationary noise conditions.

Two new algorithms with reduced sensitivity to the changing environment are applied to tracking arterial circulation parameters. They are variants of the Least-Squares (LS) algorithm with Variable Forgetting factor (LSVF), and of the Constant Forgetting factor-Covariance Modification (CFCM) LS algorithm, devised to overcome their main practical deficiencies related to noise level sensitivity and the high number of design variables, respectively. To this end, adaptive mechanisms are incorporated to estimate observation noise variance in LSVF and the rate of change for the different parameters in CFCM. Specific computer simulation experiments are presented to compare their effectiveness with the original counterparts and to provide guidelines for their optimal tuning at different noise levels. Moreover, algorithm performance degradation, consequent on changes in the noise level compared to that assumed during the tuning phase, is analyzed. In particular, it is shown that, when the noise level changes with respect to the tuning value, the new LSVF algorithm is much more robust than the original one, whose performance degrades rapidly. The new CFCM algorithm is characterized by a reduced number of design variables with respect to its original counterpart. Nevertheless, it can be preferred only when low noise signals are used for estimation.

Algorithms↗

Influence of flow pattern on the parameter estimates of a simple breathing mechanics model.

The first-order model of breathing mechanics is widely used in clinical practice to assess the viscoelastic properties of the respiratory system. Although simple, this model takes the predominant features of the pressure-flow relationship into account but gives highly systematic residuals between measured and model-predicted variables. To achieve a better fit of the entire data set, an approach hypothesizing deterministic time-variations of model parameters, summarized by information-weighted histograms was recently proposed by Bates and Lauzon. The present study uses flow and pressure data measured in intensive care patients to evaluate the real potential of this approach in clinical practice. Information-weighted histograms of the model parameters, estimated by an on-line identification algorithm, were first constructed by taking into account the parameter percentage standard deviations. Then, the influence of the respiratory flow pattern on the calculated histograms was evaluated by the Kolmogorov-Smirnov statistical test. The results show that the method gives good reproducibility under stable experimental conditions. In addition, for a given airflow waveform, an increase in respiratory frequency shifts the histograms representing time-varying viscous properties strongly versus lower values, whereas it shifts the histograms representing time-varying elastic properties slightly versus higher values. On the other hand, the same histograms were highly dependent on the airflow waveform, especially for the viscous properties. Even in a limited experimental work, in all the conditions considered, the method provides results which agree well with the physiological knowledge of nonlinear and multicompartment behavior of respiratory mechanics.

Algorithms↗

On-line estimation and prediction of urea kinetics during hemodialysis: a simulation approach.

A new method for the on-line estimation of urea kinetic parameters from blood urea concentration (BUN) continuously measured during a dialysis session is proposed. The method, based on the variable-volume double-pool model, is evaluated through a simulation approach in order to easily consider a large set of well-controlled test conditions. The model is characterized by six parameters, knowledge of which enables early prediction of the end dialysis urea concentration and the dose of dialysis. The sensitivity of the model predicted BUN with respect to the parameters was first analyzed to investigate which can be reliably estimated from blood urea measurements taken at a suitable rate. This analysis showed that the model predicted BUN is highly sensitive to the initial blood urea concentration and to the dialyzer clearance, normalized with respect to the total initial distribution volume, while it is scarcely influenced by the normalized ultrafiltration and urea generation rates. The new on-line estimation technique keeps these two last parameters constant and takes advantage of an original analytic solution of the second order urea kinetics. The results of the estimation process on realistic simulated data showed that the proposed method provides early and reliable estimates of the normalized clearance and of the end dialysis concentration. The transcellular mass transfer coefficient and the intra-extra cellular volume ratio can also be estimated, although with less accuracy. Moreover, it was shown that the use of the single-pool model, instead of the double-pool one, provides systematic errors on the estimates.

Algorithms↗

Integration of quantitative and qualitative reasoning: an expert system for cardiosurgical patients.

In this work the possibility of building an expert system to reason on the status of post-operative cardiac patients in intensive care units is analysed. The long-term knowledge consists of causal network which describes the main relationships between hemodynamic and metabolic quantities involved in the evolution after cardiac surgery. The inference engine uses an original hybrid formalism, which integrates numerical simulation and qualitative methods. If available, the numerical values of quantities and their exact mathematical relationships are employed; otherwise, the inference engine reasons by using a discrete qualitative representation of quantities. Simulations performed using real data indicate that integration of quantitative and qualitative methods reduces the number of diagnostic scenarios compatible with patient data, and constitutes a valid tool for reasoning about physiological disorders in terms of deep causal knowledge.

Atrial Function, Right↗

A four-parameter linear model for analysing cardiorespiratory data in post-operative cardiac patients.

This paper investigates the possibility of characterizing the differences between normal- and high-risk postoperative cardiac patients on the basis of four parameters related to a simple linear model of cardiorespiratory performances. The model comprises three subsystems representing cardiac, vascular and respiratory functions, respectively. These parameters, determined from physiological variables measured in the Intensive Care Unit, seem useful for clinical evaluation of patient status. In fact, their values quantify the improved cardiovascular and respiratory response that normal-risk patients exhibit to increasing metabolic needs after hypothermic treatment, with less utilization of blood oxygen reserve. In addition, a set of three parameters derived from the proposed four allows a prediction of patient class membership with an error lower than 7% when used with a Bayes quadratic classifier.

Cardiac Surgical Procedures↗

Comparison of algorithms for tracking short-term changes in arterial circulation parameters.

Three recursive methods especially suited for identification of systems with rapidly changing parameters are applied to tracking of the viscoelastic properties of the systemic arterial bed. These methods include two least squares (LS) algorithms with constant or variable forgetting factor (RLS and LSVF) and a LS algorithm incorporating both a constant forgetting factor and covariance modification (CFCM). The methods are presented in a unified framework and their sensitivity with respect to the design variables is investigated using noisy data from computer simulations. All analysed methods have shown themselves to be able to satisfactory track rapid changes in peripheral resistance. The LSVF method, which offers slightly better performances than the classical RLS, may be preferred when calculation efficiency is the prime requirement. The CFCM algorithm, although maintaining reasonable simplicity, shows the best tracking ability also on varying of the noise sequence.

Algorithms↗

Classification of postoperative cardiac patients: comparative evaluation of four algorithms.

Four classification algorithms based on Bayes' rule for minimum error are compared by evaluating their ability to recognize high- and normal-risk cardio-surgical patients. These algorithms differ in the modelling of the probability density function (pdf) for each class and include: (a) two parametric algorithms based on the assumption of normal pdf; (b) two non-parametric algorithms using Parzen multidimensional approximation of pdf with normal kernels. In each case, classes with both equal and different covariance matrices were considered. A set of 200 patients in the 6 h immediately following cardiac surgery has been used to test the performance of the algorithms. For each patient the three measured variables most effective in representing the difference between the two classes were considered. We found that the two algorithms which explicitly incorporate the information on the different sample covariance between the physiological variables existing in the two classes generally provide better recognition of high- and normal-risk patients. Of these two algorithms the parametric one appears extremely attractive for practical applications, since it exhibits slightly better performance in spite of its great simplicity.

Algorithms↗

Cluster analysis of clinical data measured in the surgical intensive care unit.

A set of 13 extensively used hemodynamic, ventilatory and gas analysis variables are measured (on-line or off-line) on 200 patients in an intensive care unit (ICU) during the 6 h immediately following cardiac surgery. In order to identify both low- and high-risk patterns, a clustering method is applied to these data at three equidistant observation times. Application of the divergence criterion allows a quantitative evaluation of the diversity between the clusters identified, showing that the two patterns are really distinct in the 13-D space. The same criterion is then used to find possible subsets of variables capable of maintaining, in time, an effective separation power. The latter always include the cardiac index (CI), representative of cardiac performance, and two indices related to respiratory efficiency and metabolic rate, i.e., the carbon dioxide production index (VCO2I) and the arterio-venous oxygen difference (avO2D).

Cardiac Surgical Procedures↗

Unsupervised learning and discriminant analysis applied to identification of high risk postoperative cardiac patients.

A set of 200 patients in the 6 hours immediately following cardiac surgery was analysed within a multidimensional space of 13 commonly monitored physiological variables in order to identify high risk patterns. The application of an unsupervised learning (clustering) method to these data clearly showed the existence of two well-separated classes of low and high risk patients. A stepwise discriminant analysis was then applied to patients representative of the two classes in order to find those variables which, over time, possessed the greatest separation power. The latter always included the oxygen delivery (DO2), an index related to the oxygen content in the blood (Pv(-)O2 or avO2D) and a myocardial contractility index (VF or LAP).

Algorithms↗

Real-time tracking of parameters of lung mechanics: emphasis on algorithm tuning.

We consider the problem of tracking rapid changes in the viscous and elastic properties of the respiratory system by using mouth flow and transpulmonary pressure data measured during mechanical ventilation. A recursive least-squares algorithm with adjustable compensator is used for online estimation of an R-C model of the breathing mechanics. Specific simulation experiments are presented to provide guidelines to select suitable values for the key variable, which controls the compromise between tracking ability and noise sensitivity. The results obtained confirm the critical role of the optimum tuning in relation to the noise level. Experimental results obtained from data measured on mechanically-ventilated dogs, in which respiratory distress syndrome was intravenously induced by oleic acid, demonstrate that the tuned algorithm is able to track appropriately both the viscous and elastic properties of lung mechanics. Parameter estimates are consistent with those obtained by standard and robust offline algorithms and their time course is in qualitative agreement with known physiopathological behaviour.

Airway Resistance↗

Sensitivity analysis of the systemic circulation with a view to computer simulation and parameter estimation.

A sensitivity analysis study has been performed on a seven-parameter model of the systemic vascular bed in order to obtain structure reductions appropriate for simulation and estimation. This analysis considers separately the systolic and diastolic transfer functions between arterial and venous pressures in order to divide a non-linear problem in two distinct linear problems. The results obtained refer to nominal parameter values corresponding to normal circulatory conditions in man and supply guide-lines for an application-oriented selection of reduced models. Simple resistance-compliance models are preferred because the inertial effects appear to have only slight influence. In particular, the choice of a five-parameter model seems to be convenient for simulation purposes. An additional structure reduction is suggested to reach reliable results in parameter estimation problems. The resulting model is characterized by three elements: peripheral resistance, arterial compliance and venous compliance.

Blood Circulation↗

Electrical analogs for monitoring vascular properties in artificial heart studies.

The problem of choosing parametric descriptions of the systemic vascular bed suitable for monitoring beat-to-beat changes in peripheral vascular properties is considered. Three simple models with two, three, and five elements are compared, essentially exploiting the Akaike information criterion combined with reasonable requirements for estimate accuracy. Analysis of pressure data, which are either simulated by the five-element model or measured on a mock circulatory system during abrupt changes in peripheral resistance, suggests guidelines for model selection. In particular, the five-element model exhibits very close adherence to physical reality by allowing for reflection, while the classical windkessel model provides the most reproducible estimates.

Cardiovascular Physiological Phenomena↗

Tracking time-varying properties of the systemic vascular bed.

The problem of tracking changes in viscoelastic properties of the systemic arterial bed is considered and a recursive estimation procedure, belonging to the class of output-error algorithms with adjustable compensator, is developed and discussed. By means of computer simulations, suitable values are determined for the key design variable which controls the tradeoff between tracking ability and noise sensitivity of the algorithm. In this way, the algorithm allows on-line estimation of arterial compliance, peripheral resistance, and characteristic impedance on the basis of aortic pressure and flow signals. Furthermore, the results obtained from data numerically simulated, as well as measured on a mock circulatory system, demonstrate that the dominant arterial time-constant can be tracked by the algorithm using only measurements of the aortic pressure during diastole.

Algorithms↗

CADCS simulation of the closed-loop cardiovascular system.

A pulsatile simulator of the closed-loop cardiovascular system, designed to solve simulation, identification and control problems in a research and education context, is presented. Its implementation makes use of a command-driven interactive program for simulation of non-linear ordinary differential equations. The flexibility of the simulator is demonstrated by the results presented which refer to a basal steady-state circulatory condition as well as a transient induced by an abrupt change in peripheral resistance.

Blood Pressure↗

Three-element model for total systemic circulation: emphasis on the accuracy of parameter estimates.

In this study, the accuracy achievable in the parameter estimates of a three-element linear model for the systemic vascular bed is considered. The model neglects inertial effects and includes only three elements representing arterial compliance, peripheral resistance and venous compliance, in agreement with recent sensitivity investigations. Parameter estimation starts from arterial and right atrial pressure signals generated by a closed-loop simulator of the cardiovascular circulation and corrupted with normal noise to account for measurement errors. In this way, the influences of a wide variety of circulatory conditions were investigated. The results achieved give evidence that arterial compliance is generally well estimated, while venous compliance is more variable, particularly at high peripheral resistance when measured signals appear to be less sensitive to this parameter. However, presence of cardiac disease, such as heart failure and valvular stenosis has minimal influence on compliance estimates. These results suggest that this simple model can be conveniently applied even under noisy conditions.

Blood Circulation↗

Model selection for ventricular mechanics: a sensitivity analysis approach.

Quantitative characterization of left ventricle pump properties has been recognized as being of great significance for both physiological and clinical purposes. Several descriptions have been proposed in the past to this end, where the ventricle is viewed as an isovolumic pressure generator coupled to an internal impedance, considered as either only viscous, only elastic or viscoelastic. Though these models have been used widely, the respective advantages and limits have not been fully elucidated. In this paper, six models for the left ventricular pumping function, of the viscoelastic type, are compared using both simulated and experimental data in a typical parameter estimation approach. Elastic and viscous parameters are estimated starting from ventricular pressure and aortic flow, together with the isovolumic pressure at the same preload. The basis for the comparison is the well-established criterion relating the fit obtained from collected data and the covariance matrix of the parameter estimates. The latter allows evaluation of the so-called indifference region in the parameter space, which is represented by an ellipse if both elastic and viscous elements are present. The properties of the indifference region are synthetically represented by two indices linked to the area and the eccentricity of the ellipse: the first represents the mean accuracy of the parameter estimate, the second gives information about the different sensitivities to variation of single parameters. This comparison, in both simulated and experimental cases, generally leads to preference for a model where elastance and viscosity vary with time in linear proportion to the isovolumically developed ventricular pressure. Appropriate description of the elastic effect reveals it to be very crucial while the viscous effect, though improving the fitting of data, is less critical.

Animals↗