PubMed Health⌕ Search

Biomedical subjects

G Bergseth

Publications and source records attributed to G Bergseth.

3 recordsLinked to original sources

A novel enzyme immunoassay for plasma thrombospondin. Comparison with beta-thromboglobulin as platelet activation marker in vitro and in vivo.

A novel enzyme immunoassay for plasma thrombospondin (TSP) based on commercially available monoclonal antibodies was established. The following conditions for correct collection and preservation of blood samples were required: venipuncture directly into a vacutainer containing citrate, theophylline, adenosine and dipyridamole, storage on ice, and separation of plasma within 30 minutes. Thereafter, the plasma TSP concentration remained constant at room temperature and after five times of freezing and thawing. Both inter- and intraassay variation coefficients were 5%. The lower detection limit was 20 microg/L. Median TSP concentration among 40 healthy blood donors was 43 microg/L, slightly lower than previously published. The assay is valid, reliable, and has certain advantages compared with previously published methods. TSP and beta-thromboglobulin (BTG) were then compared as platelet activation and biocompatibility markers in vivo: 23 patients undergoing cardiopulmonary bypass (CPB); and in vitro: effect of coating polyvinyl chloride with heparin. The kinetic patterns of TSP and BTG were markedly different in vivo but virtually identical in vitro, explained by different in vivo clearance mechanisms during CPB. We conclude that BTG is superior to TSP for evaluation of platelet activation during in vivo CPB, whereas TSP and BTG are virtually identical as markers in vitro.

Antibodies, Monoclonal↗

Platelet compatibility of an artificial surface modified with functionally active heparin.

Platelet compatibility after coating an artificial material with functionally active heparin was investigated. Blood was circulated in uncoated or heparin coated PVC tubing. In one hour platelet counts decreased from 155 (113-184)x10(9)/l to 124 (100-148)x10(9)/l with uncoated compared to 164 (132-192)x10(9)/l with heparin coated tubing (intergroup p = 0.02). Beta-thromboglobulin increased from 116 (80-148) microg/l to 1039 (757-1298) microg/l with uncoated and to 352 (229-638) microg/l with heparin coated tubing (intergroup p = 0.005). Platelet counts and beta-thromboglobulin correlated closely with complement activation. Solid-phase enzyme immunoassay demonstrated substantial deposition of CD42a/GPIbIX and CD61/GPIIIa on uncoated, but not on heparin coated tubing (intergroup p<0.0005). Scanning electron microscopy demonstrated activated platelets and aggregates on uncoated in contrast to heparin coated tubing, where scattered, unactivated platelets were found. Changes in P-selectin and microparticles were minor. In conclusion, this heparin surface substantially improved platelet compatibility. Markers of choice for in vitro evaluation were platelet counts, beta-thromboglobulin and platelet deposition.

Antigens, CD↗

Effect of time, temperature and anticoagulants on in vitro complement activation: consequences for collection and preservation of samples to be examined for complement activation.

The effects of time, temperature, ethylene-diamine-tetra-acetic acid (EDTA), citrate and heparin on in vitro complement activation were examined in enzyme immuno assays (EIA) for detection of C3 activation products and the terminal complement complex (TCC). In vitro complement activation occurred during coagulation since baseline concentrations of activation products were considerably higher in serum than in plasma. EDTA was more efficient than citrate and heparin in inhibiting in vitro activation. Minimal activation was observed in all preparations when samples were kept at 4 degrees C for up to ten days, whereas a very rapid increase in activation products occurred even in EDTA plasma when the temperature was elevated. Based on the data obtained, guidelines for the collection and preservation of samples to be examined for complement activation are given.

Blood Preservation↗