PubMed Health⌕ Search

Biomedical subjects

G Bluhm

Publications and source records attributed to G Bluhm.

18 recordsLinked to original sources

Increased prevalence of hypertension in a population exposed to aircraft noise.

OBJECTIVES: To investigate whether there is a relation between residential exposure to aircraft noise and hypertension. METHODS: The study population comprised two random samples of subjects aged 19-80 years, one including 266 residents in the vicinity of Stockholm Arlanda airport, and another comprising 2693 inhabitants in other parts of Stockholm county. The subjects were classified according to the time weighted equal energy and maximum aircraft noise levels at their residence. A questionnaire provided information on individual characteristics including history of hypertension. RESULTS: The prevalence odds ratio for hypertension adjusted for age, sex, smoking, and education was 1.6 (95% confidence interval (95% CI) 1.0 to 2.5) among those with energy averaged aircraft noise levels exceeding 55 dBA, and 1.8 (95% CI 1.1 to 2.8) among those with maximum aircraft noise levels exceeding 72 dBA. An exposure-response relation was suggested for both exposure measures. The exposure to aircraft noise seemed particularly important for older subjects and for those not reporting impaired hearing ability. CONCLUSIONS: Community exposure to aircraft noise may be associated with hypertension.

Adult↗

Estimation of Nitrous Oxide Emissions from US Grasslands.

/ Nitrous oxide (N(2)O) emissions from temperate grasslands are poorly quantified and may be an important part of the atmospheric N(2)O budget. In this study N(2)O emissions were simulated for 1052 grassland sites in the United States using the NGAS model of Parton and others (1996) coupled with an organic matter decomposition model. N(2)O flux was calculated for each site using soil and land use data obtained from the National Resource Inventory (NRI) database and weather data obtained from NASA. The estimates were regionalized based upon temperature and moisture isotherms. Annual N(2)O emissions for each region were based on the grassland area of each region and the mean estimated annual N(2)O flux from NRI grassland sites in the region. The regional fluxes ranged from 0.18 to 1.02 kg N(2)O N/ha/yr with the mean flux for all regions being 0.28 kg N(2)O N/ha/yr. Even though fluxes from the western regions were relatively low, these regions made the largest contribution to total emissions due to their large grassland area. Total US grassland N(2)O emissions were estimated to be about 67 Gg N(2)O N/yr. Emissions from the Great Plains states, which contain the largest expanse of natural grassland in the United States, were estimated to average 0.24 kg N(2)O N/ha/yr. Using the annual flux estimate for the temperate Great Plains, we estimate that temperate grasslands worldwide may potentially produce 0.27 Tg N(2)O N/yr. Even though our estimate for global temperate grassland N(2)O emissions is less than published estimates for other major temperate and tropical biomes, our results indicate that temperate grasslands are a significant part of both United States and global atmospheric N(2)O budgets. This study demonstrates the utility of models for regional N(2)O flux estimation although additional data from carefully designed field studies is needed to further validate model results.

Journal Article↗

HLA-DRB1 genes and disease severity in rheumatoid arthritis. The MIRA Trial Group. Minocycline in Rheumatoid Arthritis.

OBJECTIVE: To examine the effect of alleles encoding the "shared"/"rheumatoid" epitope on rheumatoid arthritis (RA) disease severity in patients who participated in the minocycline in RA (MIRA) trial. METHODS: Of 205 patients with a week-48 visit, blood was available for typing of HLA-DRB1 and HLA-DQB1 in 174 (85%) and successfully completed in 169 (82%). Baseline erosions were used to assess disease severity and new erosions at the last visit served as a proxy for progression. RESULTS: At baseline, there was no association between the presence of erosive disease or rheumatoid factor status and the dose of rheumatoid epitope (homozygous, heterozygous, none) or the specific alleles identified. At the final visit, a gradient was observed for the 3 allelic subgroups (and their gene doses) in the occurrence of new erosions among the Caucasian placebo-treated, but not the minocycline-treated, patients. A treatment group/HLA-DR4 epitope interaction was demonstrated in multivariate analyses. Approximately two-thirds of African-American patients did not have the rheumatoid epitope. CONCLUSION: HLA-DRB1 oligotyping may be useful in predicting the progression of disease in some Caucasian patients. Our study corroborates the infrequency of the epitope among African-American patients with RA.

Alleles↗

Nitrogen dioxide pneumonitis in ice hockey players.

Exposure to the toxic gases carbon monoxide and nitrogen dioxide (NO2) in indoor ice arenas occasionally occurs and may result in severe symptoms. The gases are produced by ice resurfacing machines operating on hydrocarbons, and in certain conditions toxic levels accumulate. The damage to lung tissues caused by NO2 may not be evident until after a latency time of 1/2-2 days. The role of corticosteroids in the treatment is controversial, but there are clinical experiences as well as experimental data supporting their use. We report two cases of toxic pneumonitis, with delayed onset, due to NO2 exposure during an ice hockey game in an indoor arena. Signs and symptoms were cough, dyspnoea, haemoptysis, hypoxaemia and reduced peak expiratory flow. Chest radiographs showed parenchymatous infiltrative lesions and alveolar consolidation. Both patients were treated with high doses of corticosteroids by inhalation and orally or intravenously. Their condition rapidly improved and pulmonary function was restored.

Adolescent↗

Long-term comparison of the electrical characteristics of polyurethane and polyethylene insulated ventricular leads.

Two types of pacing leads with different insulation material, polyurethane, and polyethylene, were followed for 44 months with respect to their electrophysiological characteristics and complications. In 48 patients, 32 polyurethane leads (Lifeline 493-03) and 16 polyethylene leads (EMT 588 D) were implanted and connected in all cases to the same type of programmable ventricular inhibited (VVI) pulse generator (Programalith, Pacesetter). There was a significant fall during the follow-up in lead impedance with the polyurethane leads (495 +/- 62 to 444 +/- 58 ohms, P less than 0.01), whereas the corresponding measurements for the polyethylene leads were essentially unchanged (360 +/- 58 to 378 +/- 71 ohm, ns). The energy of the stimulation threshold tended to increase in the polyurethane group, whereas an opposite tendency was observed in the polyethylene group. Pacing and/or lead failures were not observed in any case. The observed fall in impedance with the polyurethane leads was seemingly of no clinical significance.

Aged↗

Antibiotic prophylaxis in pacemaker surgery: a prospective double blind trial with systemic administration of antibiotic versus placebo at implantation of cardiac pacemakers.

In a double blind clinical trial, 106 consecutive patients scheduled for pacemaker implantation were randomly assigned either to a systemic prophylaxis group (SPG) (to be given flucloxacillin) or to a control group who would be given a placebo (CPG). The SPG group received 2 g IV flucloxacillin 1 hour before the operation, then 1 g perorally every 8 hours for the next five days. In the CPG group, placebo infusions and tablets were given at the same schedule. There were a total of 106 patients (SPG 52, CPG 54) who met the criteria of the study. Of these, 102 patients (SPG 50, CPG 52) completed a follow-up of 7-35 months. Infection of the pacemaker system was not diagnosed in any patient in either group. Tissue fluid was drawn 24 hours postoperatively from the pacemaker pocket for culture and for determination of pocket antibiotic concentration. The mean flucloxacillin concentration of pocket fluid from 23 patients in the SPG was 7.5 micrograms/ml. The bacteriological cultures were positive in 9/32 patients in the SPG group and in 10/34 patients in the CPG group. This study suggests that antibiotic prophylaxis need not routinely be given at implantation of permanent pacemaker systems.

Cardiac Pacing, Artificial↗

Pharmacokinetics and distribution of flucloxacillin in pacemaker patients.

The pharmacokinetics of flucloxacillin in plasma and tissue fluid after i.v. infusion of 1 g was analyzed according to an open two-compartment model in 19 patients with bradyarrhythmias (mean age 70.8 years) admitted for implantation or replacement of a permanent pacemaker system. After the first infusion of flucloxacillin (5 min), the distribution phase was rapid (t 1/2 alpha = 0.13 h). The plasma half-life of elimination (t 1/2 beta) was 1.51 h, which is almost twice as long as reported in healthy volunteers. Total plasma clearance (93.1 ml/min) was also lower than is usually found in healthy individuals, due to low renal clearance of flucloxacillin (60.2 ml/min). The total apparent volume of distribution during the beta-phase (Vdarea) was 0.172 l/kg and distribution in the central compartment (Vc) 0.064 1/kg. In each patient plasma protein binding and drug distribution to plasma water, proteins and blood cells in whole blood were determined. Binding in plasma to proteins was 91.0% and distribution to blood cells in whole blood 13.8%. The mean distribution volume of free flucloxacillin during the beta-phase (Vd beta free) was 2.18 1/kg, which exceeds total body water, suggesting possible intracellular distribution and substantial tissue binding. Plasma concentrations of flucloxacillin after the fourth dose (1 g t.i.d.) were very similar to those obtained after the first infusion and those predicted from the single dose kinetics. The concentration of flucloxacillin in fluid from the pacemaker pockets in 5 patients averaged 12.1 micrograms/ml and 9.5 micrograms/ml at 1 and 5 h, respectively, which was more than ten times the MIC-values for Staphylococcus aureus and S. epidermidis.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Pacemaker infections. A clinical study with special reference to prophylactic use of some isoxazolyl penicillins.

Infection is a major complication of pacemaker treatment. Antibiotic prophylaxis has been used in association with pacemaker surgery with conflicting results, and conclusive prospective trials are lacking. This investigation indicated that systemic antibiotic prophylaxis was of benefit when infections occurred frequently. The effect of local antibiotic prophylaxis was comparable with that of systemic prophylaxis at generator replacements. No serious adverse effects of the prophylaxis were noted. However, with modern surgical methods and hygienic principles, antibiotic prophylaxis did not seem to be necessary at implantation of new cardiac pacemakers. Once infection had developed it was difficult to eradicate and serious complications sometimes occurred. Most infections commenced in the pacemaker pocket. A few cases were cured by antibiotic treatment alone but, particularly if the infection spread along the electrode, surgery was strongly needed and in the presence of endocarditis and/or septicemia all foreign material should be removed if possible. The most common causal microorganisms of pacemaker infections were Staphylococcus aureus and Staphylococcus epidermidis. Routinely performed pre-, per- and postoperative cultures were of no prognostic value. Persistent use of antibiotics could select for methicillin-resistant coagulase-negative staphylococci, therefore bacteriological monitoring of wound infections was considered important. The dosage schedules used for cloxacillin and flucloxacillin gave satisfactory serum concentrations peroperatively. Local treatment with cloxacillin in the pacemaker pocket peroperatively gave adequate concentrations in tissue fluid from the pocket 24 h after the operation, as did systemic administration of flucloxacillin. The pharmacokinetics of flucloxacillin in these elderly patients differed in some respects from that found in healthy volunteers. Plasma elimination half-life was almost twice as long. Despite the high degree of plasma protein binding, flucloxacillin appeared to pass rapidly and efficiently to extravascular compartments, such as a pacemaker pocket.

Adult↗

Runaway pacemaker inhibited by external overdrive stimulation: a case report.

A case is described of runaway pacemaker ( Stimulith ) which could be inhibited by external chest-wall overdrive. This pulse generator had been implanted for four years before runaway occurred; the runaway rate was 140/min with capture of the ventricles. Using external chest-wall stimulation at a rate of 170/min, we were able to achieve almost complete inhibition of the faulty generator, while preparing for emergency replacement.

Cardiac Pacing, Artificial↗

Antibiotic prophylaxis in pacemaker surgery--a prospective study.

To evaluate the effect of antibiotic prophylaxis in pacemaker surgery, 100 patients were randomly assigned to a prophylaxis group receiving cloxacillin or to a control group with no antibiotics. Cloxacillin was given intravenously (2 g) 2 hours before operation, followed by 1 g every 6 hours for 2 days and the same dose perorally for 8 more days postoperatively. Adequate plasma concentrations were obtained in all patients. The follow-up time was 1-43 months. The infection rate was 2% (1/50) in the prophylaxis group and 14% (7/50) in the control group (p less than 0.05). The interval from operation to manifest infection was 9-35 days. In the control group the causal microorganism was Staphylococcus aureus in two patients, Staphylococcus epidermidis in two and unknown in three patients. In the only patient with infection in the prophylaxis group, a methicillin-resistant S. epidermidis was isolated. Infection was initially localized to the pacemaker pocket in seven patients, but septicemia developed in one of them and endocarditis in another. In one patient septicemia appeared initially, without local signs of infection. This study suggests that cloxacillin prophylaxis is of value in routine pacemaker surgery.

Aged↗

Coagulase-negative staphylococci and cloxacillin prophylaxis in pacemaker surgery.

In a prospective study of cloxacillin prophylaxis at pacemaker surgery per- and post-operative cultures were made. The most commonly isolated organisms from the wound were coagulase-negative staphylococci. These were typed by the scheme devised by Kloos and Schleifer. The routinely performed per-operative culture was of very little prognostic value. However, the typing was found to be useful in cases with suspected infection, as repeated isolation of the same species of coagulase-negative staphylococci with the same antibiotic susceptibility pattern may indicate pathogenicity. Incubation in enrichment medium for 2-4 days was needed in one patient who received antibiotic therapy when the specimen for culture was taken. The antibiotic prophylaxis did not eradicate even susceptible bacteria from the wound, but the infection rate was significantly lower in the prophylaxis group.

Adult↗

Septicaemia and endocarditis--uncommon but serious complications in connection with permanent cardiac pacing.

Between 1971 and 1978 septicaemia was observed in 14 patients undergoing permanent pacemaker treatment. The causative microorganisms were: S. aureus (9), S. epidermidis (3), alfa-haemolytic streptococci + P. morganii (1), enterococci (1). In 4 patients, a mural endocarditis of the right atrial wall surrounding the electrode was found at operation or autopsy. The interval between the preceding pacemaker operation and onset of septicaemia varied between 2 days and 23 months (median 2 months). In 5 patients, the last operation before septicaemia was performed because of local infection in the pacemaker pocket or along the electrode. A probable portal of entry was found in 11 patients. The electrode was the origin in 8, the pacemaker pocket in one, and a focus outside the pacemaker system in 2. Of the 6 patients treated with antibiotics alone, 3 were cured, 2 died and one is still on treatment. Eight patients underwent various surgical procedures in addition to the antibiotic treatment. In 4 the electrode was completely removed. In 2 of them cardiotomy during extracorporeal circulation had to be used. All of these patients were cured. In 3 the pacemaker system was partially extracted. Only one of them was cured, one developed osteomyelitis and one died. Based on our experience, we now recommend that all foreign material should be removed, if possible, in the presence of septicaemia and/or endocarditis, and that parenteral antibiotic treatment should be given for at least 6 weeks.

Aged↗

Health effects resulting from nitrogen dioxide exposure in an indoor ice arena.

We investigated an outbreak of acute respiratory illness among adolescent ice-hockey players in an indoor ice arena in Stockholm that had a propane-powered ice-resurfacing machine. We administered questionnaires to all players, as well as to a reference group that had played ice hockey in indoor arenas with electric ice-resurfacing machines. In the exposed group, 55 subjects (55.6%) experienced acute respiratory symptoms, compared with 4 (7.1%) in the reference group (relative risk = 7.8; 95% confidence interval = 3.0, 20.3). The risk for pulmonary symptoms increased as time spent on the ice increased. Levels of nitrogen dioxide up to 2358 microg/m3 (1250 ppb) were detected during simulated conditions of the incident. The most likely cause of the outbreak was the high level of nitrogen dioxide that resulted from poor ventilation and a malfunctioning ice-resurfacing machine. Propane-fueled ice-resurfacing machines should not be used in indoor ice arenas.

Adolescent↗

Road traffic noise and annoyance--an increasing environmental health problem.

Traffic noise, which is steadily increasing, is considered to be an important environmental health problem. The aim of this study was to estimate the degree of annoyance and sleep disturbance related to road traffic noise in residential settings in an urban community. The study is based on a questionnaire on environmentally related health effects distributed to a stratified random sample of 1000 individuals, 19-80 years old, in a municipality with heavy traffic in the county of Stockholm. The response rate was 76%. The individual noise exposure was estimated using evaluated noise dispersion models and local noise assessments. Frequent annoyance was reported by 13% of subjects exposed to Leq 24 hr >50 dBA compared to 2% among those exposed to <50 dBA, resulting in a difference of 11% (95% Confidence Interval (CI) 7%, 15%). Sometimes or frequently occurring sleep disturbance was reported by 23% at Leq 24 hr >50 dBA and by 13% at levels <50 dBA, a difference of 11% (95% CI 4%, 18%). A positive exposure- response relation was indicated for annoyance as well as for sleep disturbances when classifying the individuals into four different exposure categories (< 45, 46- 50, 51-55 and >55 dBA Leq 24 hr). There was some habituation to noise for problems related to sleep but not for annoyance. The prevalence of both annoyance and sleep problems was higher when bedroom windows were facing streets. People living in apartments had more sleep problems compared to people living in detached or semi-detached houses. In conclusion traffic noise exposure, even at low levels, was associated with annoyance and sleep disturbance. Access to a quiet side seemed to be a major protective factor for noise related problems.

Adult↗