PubMed Health⌕ Search

Biomedical subjects

G Bodner

Publications and source records attributed to G Bodner.

At least 37 records · Page 2Linked to original sources

Extraanatomical coronary artery bypass grafts on the beating heart for management of the severely atherosclerotic ascending aorta.

BACKGROUND: Crossclamping a severely atherosclerotic ascending aorta carries a significant risk of stroke in coronary artery bypass grafting. Besides other techniques aortic no touch concepts are increasingly applied for management of this problem. METHODS: Out of 407 patients undergoing epiaortic scanning during coronary artery bypass grafting 38 (9.3%) exhibited severe ascending aortic atherosclerosis. 22 of these patients (18 male, 4 female, age 72 (57-79) years, Parsonnet Score 11 (0-18), Euro Score 8 (2-13), McSPI Stroke Risk Index 6 (1-30) %) were operated on using a beating heart and aortic no touch technique. All patients received at least one internal mammary artery (IMA) in situ graft and additional extraanatomical bypass conduits: venous Y-graft from the IMA (n=14), arterial Y-graft from the IMA (n=3), vein graft from the axillary artery (n=3), vein graft from the IMA stump (n=2), vein graft from the innominate artery (n=2). RESULTS: No stroke occurred. The rate of perioperative myocardial infarction (CKMB rt; 50 U/l) was 5/22. Median ICU length of stay was 54 (15-1245) h. Hospital mortality was 2/22. Pre- and postoperative angina class (CCSC) were 3.3 +/- 0.9 and 1.4 +/- 0.9 respectively (p<0.001). After a median follow up period of 8 months 3 deaths, one stroke, and one myocardial infarction occurred. On 3D multislice CT scan reconstructions which were performed in 13 patients during the first postoperative year all IMA grafts to the LAD and 11 out of 13 extraanatomical vein grafts were shown to be patent. CONCLUSION: Performance of beating heart extraanatomical coronary artery bypass grafts for management of a heavily diseased ascending aorta can result in a very low stroke rate despite a considerable stroke risk. The complexity of the procedures may be reflected by a relatively high rate of perioperative myocardial infarctions. Perioperative mortality as well as short term patency of extraanatomical bypass grafts seem to be acceptable.

Aged↗

Small free vascularized iliac crest bone grafts in reconstruction of the scaphoid bone: a retrospective study in 60 cases.

Carpal instability may result in progressive degenerative arthritis of the wrist. The surgical goal of the reconstruction of scaphoid nonunion is to achieve bone union and to restore the scaphoid. Many procedures are described to treat scaphoid nonunion for different indications. This retrospective study reports on the anatomical fundamentals, the operative procedure, and the results of 60 patients (21 with recalcitrant scaphoid nonunion that lasted longer than 4 years, 26 with an avascular pole fragment, and 13 with scaphoid nonunion after previous surgery) who were treated by a small free vascularized iliac crest bone graft. All 60 patients have routinely been followed up clinically and with magnetic resonance imaging. Union was achieved in 91.7 percent by improvement of stability and the compromised vascularity of the scaphoid. The bone flap loss rate and persisting nonunion was 8.3 percent, leading to progressive arthritis and carpal collapse. Complaints concerning discomforts caused by the scar were heard from 40.1 percent of the patients, and 31.7 percent complained of discomforts caused by the bony deformity. Bone deformations on the donor site were detected radiologically in 63.3 percent of the patients. In 31.7 percent, an impairment of the lateral femoral cutaneous nerve was noted. Reconstruction of the scaphoid by means of implantation of a vascularized iliac bone graft proved efficient to treat avascular recalcitrant scaphoid nonunion and pseudarthrosis with avascular proximal pole fragments.

Adolescent↗

New, simple, ultrasound-guided infiltration of the pudendal nerve: ultrasonographic technique.

PURPOSE: Anesthetic infiltration of the pudendal nerve at the ischial spine can relieve perineal pain in cases of compression or distention. The aim of our study was to look for a real-time, visually controlled infiltration technique using ultrasound. METHODS: Fifty-three volunteers were examined in a prone position using a 3.5-MHz curved-array probe in color-coded Doppler mode. The deep gluteal region was scanned in two perpendicular planes, longitudinal and transverse to the internal pudendal artery. RESULTS: On the transverse planes the ischial spine, the sacrospinous ligament, and the internal pudendal artery were depicted in all but two cases. In 47.2 percent of the cases one trunk of the pudendal nerve was detected directly. Nerves consisting of more than one trunk were not found. The thickness of the nerve ranged between 3.5 and 7 mm. CONCLUSIONS: In almost one-half of the cases a direct ultrasound-guided infiltration of the pudendal nerve is possible. In the remaining cases the nerve can be detected and blocked indirectly, using the ischial spine or the internal pudendal artery as a landmark.

Adolescent↗

The short-term effect of stabilization-type splints on the local asymmetry of masseter muscle sites.

Patients with temporomandibular disorders (TMD) may present with a cluster of joint and muscle disorders characterized primarily by pain, joint sounds and irregular or deviating jaw function. Maxillary stabilization-type splints represent the best standard therapy, so the purpose of this study was to evaluate changes in local cross-sectional dimensions (LCSD) of masseter muscle sites associated with short-term application of 'splint therapy' using the diagnostic approach of high-resolution gray-scale ultrasonography. The study included 29 patients who had signs and symptoms of temporomandibular disorders. Ultrasonographic investigation was performed with a linear (B-scan) 7.5 MHz small-part transducer to visualize the antero-superior, antero-inferior, medio-superior, medio-inferior, postero-superior and postero-inferior sites of the masseter muscle. To assess local muscle asymmetry patterns and to evaluate the respective effect of occluding splints, the 'absolute asymmetry index (AAI)' was used, with the mean maximum muscle diameter of the respective right and left sides calculated from three consecutive measurements before and after splint therapy. Comparing the pre-treatment with the 2-month follow-up values revealed a significant decrease in the overall mean asymmetry indices at the anterior (P < 0.01), medial (P < 0.05) and posterior (P < 0.05) muscle sites. There was no significant change in LCSDs at the various muscle sites (P > 0.05). The results of this study suggest stabilization-type splints to be effective in reducing local muscle asymmetries. Further studies are warranted to evaluate muscle-site specific effects in patient and non-patient groups and to relate these effects to pre-treatment variables like bite force, preferred chewing side, facial morphology and occlusion.

Adult↗

High-resolution ultrasonography of the TMJ: helpful diagnostic approach for patients with TMJ disorders ?

PURPOSE: The purpose of this study was to investigate patients with a clinical diagnosis of internal derangement to determine the diagnostic value of static high resolution ultrasonography (HR-US) when compared with magnetic resonance imaging (MRI). PATIENTS: Sixty-six patients (132 temporomandibular joints [TMJs]) with a clinical diagnosis of internal derangement were investigated by HR-US and MRI. METHODS: MRI and HR-US investigations were performed by experienced radiologists. The sonograms were done with a real-time 12-Mhz linear-array scanner. The HR-US interpretation errors were re-evaluated retrospectively by the same radiologist knowing the MRI results by comparing these with the 'prospective' and 'retrospective' diagnoses. The prospective and retrospective diagnoses were also compared with each other. RESULTS: Eighty-seven of the 132 TMJs had a disc displacement proved by MRI in the closed-mouth position. At maximum mouth opening, 54 TMJs had a disc displacement. The prospective interpretations showed a sensitivity and specificity of 78% each, accounting for an accuracy of 78%. At maximum mouth opening, HR-US resulted in a sensitivity of 61%, a specificity of 88% and an accuracy of 77%. The retrospective interpretations yielded a sensitivity of 90%, a specificity of 84% and an accuracy of 88% in the closed-mouth position. At maximum mouth opening, HR-US showed a sensitivity of 73%, a specificity of 95% and an accuracy of 86%. CONCLUSION: HR-US is suitable for the detection of disc displacements in the TMJ. However, further studies may be warranted to reduce the proportion of false-positive interpretations, thereby avoiding the application of unnecessary treatment.

Adolescent↗

[Color-coded doppler sonographic demonstration of intrahepatic venous collaterals in Budd-Chiari syndrome].

By means of colour Doppler ultrasound, veno-venous shunts were found in 3 cases, leading to the diagnosis of Budd-Chiari Syndrome. Pulsed and colour Doppler ultrasound showed a reduction in venous blood flow and the reversal of blood flow in the venous collaterals. Venous spectral Doppler wave forms in the veno-venous shunts were flattened and aphasic in all cases. Sonographic findings were confirmed by cavography. Our cases show that pulsed and colour Doppler ultrasound are a valuable tool in the initial diagnosis of veno-venous shunts associated with Budd-Chiari Syndrome.

Adult↗

[Effectiveness of locoregional rt-PA lysis in acute leg and arm vein thrombosis].

39 patients suffering from a thrombosis of the peripheral venous system were treated with a loco-regional lysis, using rt-PA. Two cycles of 40 mg rt-PA a day were applicated by means of a special drainage-management, using perforans veins. During lytic therapy, 20,000 to 30,000 IE of unfractionized heparin were additionally administered. Laboratory work including aPTT and fibrinogen measurement was performed every 8 hours. Additionally a phlebography was performed after 24 hours. Patients received an anticoagulative therapy using sintrom or marcumar the following 3 months. We obtained a successful thrombolysis without any major complications in 90%. Minor complications included 3 peripheral pulmonary embolisms. Duplex sonographic and plethysmographic follow up was performed in 25 patients one year after operation. In two patients with ankle edema insufficient valves at the popliteal vein were found with both diagnostic modalities. 23 patients showed no signs of insufficient valves neither clinically nor at duplex sonography and plethysmography. The locoregional lysis appears to be an effective method for the treatment of acute peripheral vein thrombosis.

Acute Disease↗

[Simulation of the heart action: a computer controlled module for the generation of variable flow patterns].

AIM: The development of a computer controlled pump for the generation of variable flow patterns with high reproducibility for simulating the haemodynamics in physiological model circuits. MATERIAL AND METHODS: The module is controlled by an arbitrary function generator. The shape of the flow profile is generated on the PC based on mathematical functions or drawn by hand. The amplified signal drives a DC motor which is coupled magnetically to a geared pumphead. The lack of mechanical coupling ensures smooth running and a complete attenuation of motor vibrations as well as a disturbance-free flow profile. The spectra were analyzed by Doppler-sonography with a 5 - 12 MHz linear probe and with pressure sensors. Silicon tubes were used as simulated vessels and a water-glycerine mixture with particles of cellulose as simulated blood. RESULTS: The generated flow patterns (constant flow and multi-phase patterns) correlate highly with the measured pressure- and velocity profiles. CONCLUSION: The variability and high reproducibility of the flow profiles and the realtime control of the signal parameters make the simulation of dynamic processes and haemodynamic long-time studies feasible. The module developed facilitates detailed studies of high reproducibility with physiological and pathological flow models and with simulated blood.

Computer Simulation↗

Radial nerve palsy associated with humeral shaft fracture: evaluation with US--initial experience.

PURPOSE: To determine the feasibility of using ultrasonography (US) for evaluation of a radial nerve injury associated with humeral shaft fracture. MATERIALS AND METHODS: In a prospective study, 11 consecutive patients with sensorimotor radial deficiency after distal humeral fracture were evaluated with conventional radiography, US, electroneurography, and electromyography. Surgical repair of the fracture and nerve inspection were performed in five patients. The remaining six patients were successfully treated conservatively. The US appearance of the radial nerve was studied in 10 healthy volunteers and in the noninjured arm of the 11 patients for comparison. RESULTS: In five patients, US findings of a severely damaged radial nerve were confirmed at surgical nerve inspection. In one patient, the nerve was entrapped between fragments. One patient had a complete nerve dissection, one had a lacerated nerve from a loose compression plate, and one had a nerve riding on the edge of a bone fragment. In the fifth patient who underwent surgical inspection, the nerve was buried in the callus. In the six patients treated conservatively, US showed continuity of the nerve. CONCLUSION: US may be useful for accurate evaluation of the radial nerve in patients with nerve palsy associated with humeral shaft fracture.

Adult↗

[Influence of reflex zone therapy of the feet on intestinal blood flow measured by color Doppler sonography].

OBJECTIVE: An influence on organ-associated blood flow is considered as a possible mechanism of action of reflex zone massage of the feet (FRZM) therapy. In the present study we investigated whether changes in intestinal blood flow can be achieved by FRZM. MATERIAL AND METHODS: 32 healthy adults (19 women and 13 men) were randomly assigned to the treatment or the placebo group. Subjects of the treatment group received foot massage on the zones assigned to the intestines and those of the placebo group received massage on zones unrelated to the intestines. Before, during and after FRZM, the blood flow velocity, the peak systolic and the end diastolic velocities in the superior mesenteric artery as well as the resistive index as a parameter of vascular resistance were calculated. RESULTS: During FRZM, in the subjects of the treatment group there was a significant reduction in the resistive index (p = 0.021), suggesting an increase in the blood flow in the superior mesenteric artery and the subordinate vascular system. In contrast, there were no significant changes in the resistive index in the subjects of the placebo group. CONCLUSION: The reduction in the resistive index observed in the treatment group supports the assumption that FRZM improves blood flow in the organs considered to be associated with the specific foot zones, at least during the therapy process.

Adult↗

Examination of postoperative peripheral nerve lesions with high-resolution sonography.

OBJECTIVE: Peripheral nerve lesions after surgery are common and are related either to direct compromise of the nerve by the surgical procedure (iatrogenic lesions) or to postoperative events such as scar formation. Despite a high sensitivity, electrodiagnosis may not reveal the exact location and cause of a nerve lesion. We hypothesized that high-resolution sonography could be helpful in diagnosing postoperative peripheral nerve lesions by direct visualization of the nerve and surrounding tissues. SUBJECTS AND METHODS: Eighteen patients with postoperative peripheral nerve lesions that were confirmed with clinical examination and electrodiagnosis were examined on sonography. Eight patients had lesions caused by direct nerve surgery, and 10 patients had undergone a previous orthopedic operation or open biopsy. Sonographic diagnoses were correlated with neurologic examinations and surgical findings. RESULTS: Reliable visualization of injured nerves on sonography was feasible in all patients. Axonal swelling of a nerve was diagnosed in three patients, direct compromise of a nerve by surrounding scar tissue or surgical implants was diagnosed in 10 patients, a neuroma was diagnosed in three, and insufficient surgical repair, in two. Sonographic findings were confirmed during surgery in all except one patient. CONCLUSION: In contrast to electrophysiologic tests, high-resolution sonography can show the exact location, extent, and type of a postoperative peripheral nerve lesion and the concurrent disease of surrounding tissues. Because the latter can often be the causative agent for the development of a lesion or the lack of improvement with conservative treatment, sonography yields important information that may not be obtained with other diagnostic modalities.

Adult↗

Can the dimensions of artificial tendon lesions be predicted ultrasonographically? A cadaveric study.

OBJECTIVE: To prove the reliable assessment of artificial partial tendon lesions in cadavers. METHODS: The tendon of the tibialis anterior muscle was cut twice (transversely, not standardized depths) along its dorsal surface. The dimensions were measured by using a 10-MHz linear probe and a gliding caliper. The lesions were classified as type A tears (<60%; n = 15) and type B tears (>60%; n = 28). RESULTS: The depths of type A tears had high correlation (r = 0.827), and those of type B tears had low correlation (r = 0.415). This low correlation was due to subtotal lesions (50%-70%; r = 0.699). High-resolution ultrasonography allowed the correct detection of 14 type A tears and 21 type B tears (kappa = 0.63; accuracy, 81%; type B tears: sensitivity, 75%; specificity, 93%). CONCLUSIONS: High-resolution ultrasonography is able to assess the dimensions of artificial partial tendon lesions in cadavers and would be an accurate tool for determining the lesion percentages in patients with partial tendon tears.

Cadaver↗

Virtual computed tomography colonoscopy: artifacts, image quality and radiation dose load in a cadaver study.

The purpose of our study was to evaluate the interdependency of spatial resolution, image reconstruction artifacts, and radiation doses in virtual CT colonoscopy by comparing various CT scanning protocols. A pig's colon with several artificial polypoid lesions was imaged after air insufflation with helical CT scanning using 1-, 3-, and 5-mm collimation, and pitch values varying from 1.0 to 3.0. Virtual endoscopic images and "fly through" sequences were calculated on a Sun Sparc 20 workstation (Navigator Software, GE Medical Systems, Milwaukee, Wis.). Several reconstruction artifacts as well as overall image quality were evaluated by three independent reviewers. In addition, radiation doses for the different CT protocols were measured as multiple-scan average dose using a 10-cm ion chamber and a standard Plexiglass body phantom. Generally, image quality and reconstruction artifacts were less affected by pitch values than by beam collimation. Thus, narrow beam collimation at higher pitch values (e. g. 3 mm/2.0) seems to be a reasonable compromise between quality of virtual endoscopic images and radiation dose load.

Animals↗

Color and pulsed Doppler ultrasound findings in normally functioning transjugular intrahepatic portosystemic shunts.

OBJECTIVE: To evaluate blood flow changes inside normally functioning transjugular intrahepatic portosystemic shunts (TIPS), using color Doppler ultrasound (CDUS) and pulsed Doppler ultrasound (PDUS). METHODS: A total of 72 patients (mean age 54, range 36-78 years) underwent TIPS placement, portal angiography, CDUS and PDUS examinations. Measurements inside the stent were taken at the portal side, at the central part and at the venous end of the TIPS. RESULTS: In well functioning TIPS the mean peak velocity (PV) on the portal side was 37 m/s (range 22-65 cm/s), in the area of the incoming intrahepatic portal branch the mean PV was 59 cm/s (range 40-95 cm/s) and at the side of the incoming hepatic vein the mean PV was 135 cm/s (range 88-220 cm/s). In the punctured hepatic and portal veins the mean PV was 25 cm/s (range 15-30 cm/s) and 18 cm/s (10-22 cm/s), respectively. The flow increase from the portal to the mid part (P less than or = 0.001) and to the venous side was statistically significant (P less than or = 0.001). CONCLUSION: A velocity gradient between the portal and the venous side of a TIPS is a normal finding caused by branches of the portal and hepatic vein joining the TIPS from the side and it is characteristic of a normally functioning TIPS.

Adult↗

The use of a graft from the second extensor compartment to reconstruct the A2 flexor pulley in the long finger.

A 10 mm wide ring graft from the second extensor compartment with periosteum from the floor of the sheath was used to correct bowstringing in six patients who sustained an isolated rupture of the A2 pulley. It was attached to the lateral rims of the sheath. Periosteum was used for additional graft fixation. Bowstringing was assessed by magnetic resonance imaging and ultrasound preoperatively and 19.5 months after surgery. It was corrected in five patients and improved in one. Pain was reduced from 35 to 7 points on a visual analogue scale. Digital circumference decreased from 76 to 71 mm. Flexion at the PIP joint increased from 88 degrees to 116 degrees. Pinch grip improved from 28 to 56 N.

Adult↗

[Value of high-resolution ultrasound in the evaluation of finger injuries in extreme sport climbers].

AIM: To determine the value of high-resolution ultrasound in the evaluation of finger injuries and changes due to strain in the fingers of extreme rock climbers. METHODS: High-frequency ultrasound was performed on 208 fingers of 52 extreme rock climbers (mean age: 29.7 yrs) and on 80 fingers of 20 healthy volunteers (mean age: 28.5 yrs). The following parameters were sonographically assessed: thickness of the pulley-system A2, distance between phalanx and tendon (PS distance), gliding ability of the flexor tendons, and the periarticular and peri-tendinous space. The examination was performed on the handling in a supinated position with extended fingers, followed by active and passive flexion of about 40 degrees. All climbers also underwent clinical examination. RESULTS: The pulley-system of climbers showed a significantly increased thickness of 0.17 (+/- 0.09) cm compared with the healthy volunteers (p < 0.001). PS-distances of up to 0.51 (+/- 0.15) cm were found only in symptomatic climbers and proved to be a sign of tendon bow-stringing. No impairment of gliding ability was seen in both groups. Tendon sheath cysts were detected in 76% (62) of symptomatic fingers of the climbers. CONCLUSIONS: Non-invasive high-resolution ultrasound examination of fingers proved to be a very helpful method for diagnosing changes due to strain as well as finger injuries in rock climbers, especially in cases where the clinical examination was difficult to perform.

Adult↗