PubMed Health⌕ Search

Biomedical subjects

G Bongartz

Publications and source records attributed to G Bongartz.

At least 19 recordsLinked to original sources

Unenhanced helical computed tomography vs intravenous urography in patients with acute flank pain: accuracy and economic impact in a randomized prospective trial.

Unenhanced helical computed tomography (UHCT) has evolved into a well-accepted alternative to intravenous urography (IVU) in patients with acute flank pain and suspected ureterolithiasis. The purpose of our randomized prospective study was to analyse the diagnostic accuracy of UHCT vs IVU in the normal clinical setting with special interest on economic impact, applied radiation dose and time savings in patient management. A total of 122 consecutive patients with acute flank pain suggestive of urolithiasis were randomized for UHCT ( n=59) or IVU ( n=63). Patient management (time, contrast media), costs and radiation dose were analysed. The films were independently interpreted by four radiologists, unaware of previous findings, clinical history and clinical outcome. Alternative diagnoses if present were assessed. Direct costs of UHCT and IVU are nearly identical (310/309 Euro). Indirect costs are much lower for UHCT because it saves examination time and when performed immediately initial abdominal plain film (KUB) and sonography are not necessary. Time delay between access to the emergency room and start of the imaging procedure was 32 h 7 min for UHCT and 36 h 55 min for IVU. The UHCT took an average in-room time of 23 min vs 1 h 21 min for IVU. Mild to moderate adverse reactions for contrast material were seen in 3 (5%) patients. The UHCT was safe, as no contrast material was needed. The mean applied radiation dose was 3.3 mSv for IVU and 6.5 mSv for UHCT. Alternative diagnoses were identified in 4 (7%) UHCT patients and 3 (5%) IVU patients. Sensitivity and specificity of UHCT and IVU was 94.1 and 94.2%, and 85.2 and 90.4%, respectively. In patients with suspected renal colic KUB and US may be the least expensive and most easily accessable modalities; however, if needed and available, UHCT can be considered a better alternative than IVU because it has a higher diagnostic accuracy and a better economic impact since it is more effective, faster, less expensive and less risky than IVU. In addition, it also has the capability of detecting various additional renal and extrarenal pathologies.

Acute Disease↗

Magnetic resonance imaging of metastatic disease to the brain with gadobenate dimeglumine.

Seventy-four patients with one to eight proven intraaxial brain metastases received a total cumulative dose of 0.2 mmol/kg bodyweight gadobenate dimeglumine, administered as sequential injections of 0.05, 0.05 and 0.1 m mol/kg over a 20-min period. MR imaging was performed before the first administration (T2- and T1-weighted sequences) and after each injection of contrast agent (T1-weighted sequences only). Quantitative assessment of images revealed significant (P <0.01) dose-related increases in lesion-to-brain (L/B) ratio and percent enhancement of lesion signal intensity. Qualitative assessment by two independent, blinded assessors revealed additional lesions in 22%, 25% and 38% (assessor 1) and 29%, 32% and 34% (assessor 2) of patients after each cumulative dose when compared with combined T1- and T2-weighted pre-contrast images. Significantly more lesions (P < 0.01) were noted by both assessors after the first injection and by one assessor after each subsequent injection. For patients with just one lesion observed on unenhanced T1- and T2-weighted images, additional lesions were noted in 12%, 16% and 28% of patients by assessor 1 following each dose and in 24%, 27% and 30% of patients by assessor 2. Contemporaneously, diagnostic confidence was increased and lesion conspicuity improved over unenhanced MRI. For patients with one lesion observed after an initial dose of 0.05 mmol/kg, additional lesions were noted by assessors 1 and 2 in 9.1% and 11.8% of patients, respectively, after a cumulative dose of 0.1 mmol/kg and in a further 9.1% and 5.9% of patients, respectively, after a cumulative dose of 0.2 mmol/kg. No safety concerns were apparent.

Brain Neoplasms↗

Multi-centre clinical study evaluating the efficacy of SonoVue (BR1), a new ultrasound contrast agent in Doppler investigation of focal hepatic lesions.

OBJECTIVES: SonoVue is a new ultrasound contrast agent, which consists of stabilised microbubbles of a sulphur hexafluoride gas. The aim of the study was to assess its efficacy in the Doppler investigation of focal hepatic lesions. MATERIALS AND METHODS: Seventy patients with focal liver tumours were studied. Four doses (0.3, 0.6, 1.2 and 2.4 ml) of SonoVue were administered intravenously with at least 10 min delay between each injection. A complete colour/power and spectral Doppler imaging investigation of the lesions was performed at baseline pre-dosing and after each SonoVue injection. All examinations were recorded on SVHS videotapes. Baseline and post contrast videotapes were reviewed by the on-site (un-blinded) investigators and by two off-site blinded readers (a) to grade the global quality of the Doppler scans of the focal lesions vascularity and the normal parenchymal vessels (b) to measure the duration of clinically useful Doppler signal enhancement and (c) to determine the diagnostic accuracy and performance of the enhanced versus unenhanced scans using histopathology, tumour markers, CT and/or MR as the reference standard. RESULTS: A statistically significant improvement was observed at all four SonoVue doses in the off site assessment of global quality of the Doppler examination of tumoral and normal parenchymal vessels in comparison with the baseline (P < 0.05). The median duration of clinically useful enhancement was significantly increased with increasing doses (P < 0.001), ranging between 1.4-2.2 min for the lowest dose and 3.2-3.8 min for the highest dose for the off-site readers. On-site assessment of diagnostic accuracy showed a significant increase in the specificity of the Doppler diagnoses (P < 0.0016) with an increase in the positive and negative predictive values and in the likelihood ratio in differentiating between benign and malignant lesions. Off-site evaluation showed a significant increase in the accuracy of enhanced Doppler diagnosis in comparison with the baseline performance. CONCLUSION: The results suggest that SonoVue is effective in improving the display of tumoral vascularisation and may be useful in the characterisation of focal liver lesions.

Contrast Media↗

Three-dimensional dynamic MR-hysterosalpingography; a new, low invasive, radiation-free and less painful radiological approach to female infertility.

BACKGROUND: The purpose of this study was to propose a new method for imaging the uterine cavity and Fallopian tube patency by three-dimensional dynamic magnetic resonance hysterosalpingography (3D dMR-HSG) and to analyse if, by using a higher viscosity contrast solution, direct visualization of the Fallopian tubes may be achieved by this new technique. METHODS: 10 consecutive infertile women underwent 3D dMR-HSG and conventional HSG as gold standard. 3D dMR-HSG consisted of injection of 20 ml of a gadolinium-polyvidone solution into the uterine cavity while acquiring five consecutive three-dimensional (3D) T1-weighted MR-sequences. RESULTS: In three patients the catheter became dislodged during 3D dMR-HSG. However, in one of these patients the examination was still partially diagnostic. Imaging findings of 3D dMR-HSG showed good correlation with conventional hysterosalpingography and allowed 3D imaging of the uterine cavity and of Fallopian tube patency in 8/10 patients and direct visualization of the Fallopian tubes in 5/7 patients. CONCLUSION: 3D dMR-HSG represents a new and promising imaging approach to female infertility causing less pain and avoiding exposure of the ovaries to ionizing radiation. By using a higher viscosity MR-contrast agent it allows not only visualization of uterine cavity and Fallopian tube patency but also direct visualization of Fallopian tubes.

Adult↗

Dynamic time-resolved contrast-enhanced two-dimensional MR projection angiography of the pulmonary circulation: standard technique and clinical applications.

OBJECTIVE: Time-resolved pulmonary two-dimensional MR projection angiography is a fast acquisition technique that allows the generation of dynamic projection angiograms by a method similar to that used to generate digital subtraction angiograms. MR images are obtained after subtracting the mask defined at the beginning of the sequence from later images, thus generating time-resolved continuous projection angiograms that depict the passage of a bolus through the pulmonary circulation. This article describes the application of this novel technique in three patients with pathologic conditions not previously described with this modality and two control subjects. CONCLUSION: The analysis of the findings on dynamic time-resolved contrast-enhanced two-dimensional MR projection angiography shows that this technique is useful not only in revealing morphologic changes associated with pulmonary disorders but also in following the passage of the bolus through the cardiopulmonary circulation. The latter capability allows qualitative detection of normal or abnormal pathways and thus is potentially of value in the assessment of several pulmonary disorders.

Adolescent↗

CT findings in eosinophilic enterocolitis with predominantly serosal and muscular bowel wall infiltration.

A 44-year-old female presented with tenderness of her abdomen, vomiting, intestinal obstruction, hypoalbuminemia and blood eosinophilia. Gastroscopy was normal and colonoscopic biopsies showed only non-specific inflammation of the colonic mucosa and submucosa. CT revealed large amounts of ascites and bilateral pleural effusions but eosinophil counts in the ascites were normal. At CT the jejunum was dilated and showed marked prominence of the valvulae whereas the ileum and the colon presented with a diffuse and hypoattenuating bowel wall thickening. The bowel wall thickening was most pronounced in the colon which especially showed also an impressive thickening and hyperenhancement mainly of its outer bowel wall layers. Parasitic infection could be excluded as well as a specific allergic response. In context with the known blood eosinophilia the diagnosis of an eosinophilic enterocolitis was suspected already by CT but finally only surgical full thickness biopsies could confirm the rare diagnosis of an eosinophilic enterocolitis with predominantly serosal and muscular bowel wall infiltration.

Adult↗

Slow clearance gadolinium-based extracellular and intravascular contrast media for three-dimensional MR angiography.

The objective of this study was to assess two new slow-clearance contrast media with extracellular and intravascular distribution for magnetic resonance angiography (MRA). Extracellular Gd-DTPA-BC(2)glucA and intravascular Gd(DO3A)(3)-lys(16) were developed within the European Biomed2 MACE Program and compared with two reference compounds, intravascular CMD-A2-Gd-DOTA and extracellular GdDOTA, in 12 rats. Pre- and post-contrast three-dimensional MR (TR/TE = 5 msec/2.2 msec; isotropic voxel size 0.86 mm(3)) was acquired for 2 hours. Signal-to-noise enhancement (DeltaSNR) was calculated. Two minutes after injection, all contrast media provided strong vascular signal enhancement. The DeltaSNR for Gd-DTPA-BC(2)glucA, Gd(DO3A)(3)-lys(16), CMD-A2-Gd-DOTA, and GdDOTA were 13.0 +/- 1.8, 25.0 +/- 3.2, 25.0 +/- 4.0, and 18.0 +/- 3.4, respectively. Gd-DTPA-BC(2)glucA, Gd(DO3A)(3)-lys(16), and CMD-A2-Gd-DOTA cleared slowly from the circulation, whereas GdDOTA cleared rapidly. Vascular DeltaSNR at 2 hours were 2.9 +/- 0.6, 25.0 +/- 3.2, 25.0 +/- 4.0, and 0.4 +/- 1.0. Gd(DO3A)(3)-lys(16) provided strong vascular and minor background enhancement, and thus may be useful for MRA or perfusion imaging. Gd-DTPA-BC(2)glucA produces persistent enhancement of extracellular water, and thus may allow quantification of extracellular distribution volume and assessment of myocardial viability.

Animals↗

Imaging findings in idiopathic pelvic fibrosis.

Two patients presented with ureteric obstruction, and voiding symptoms and constipation, respectively, and were examined by means of intravenous urography and computed tomography. One patient was additionally examined by means of MR tomography. After CT (performed in both patients) and MRT (performed in one patient) had shown a diffuse, contrast-enhancing, infiltrating process in the small pelvis with infiltration of adjacent organs and vessels, surgical biopsy proved the diagnosis of idiopathic pelvic fibrosis. Extension of retroperitoneal fibrosis below the pelvic rim is very rare. Clinical symptoms of pelvic fibrosis are variable and imaging findings may lead to a broad list of differential diagnoses. We present two patients with idiopathic pelvic fibrosis and discuss radiological findings and differential diagnoses of this rare disease.

Biopsy, Needle↗

Preliminary experience with dynamic MR projection angiography in the evaluation of cervicocranial steno-occlusive disease.

The application of a contrast-enhanced, two-dimensional MR technique, which provides dynamic projection angiograms at a subsecond temporal frame rate for depiction of the cervical and intracranial arteries, was evaluated in three healthy volunteers and seven patients with various cervicocranial steno-occlusive diseases. Intra-arterial digital subtraction angiography (DSA) served as standard of reference for findings in the patients. Magnetic resonance projection angiography (MRPA) was performed on a standard 1.5-T clinical MR imaging system at intravenous injection of a single dose of contrast agent (0.1 mmol/kg GdDTPA-BMA). Sixty consecutive images of the cerebral circulation were acquired at a temporal frame rate of 900 ms per image in the coronal plane. The collateral flow and the perfusion of the compromised vessel territory were readily assessed by MPRA in patients with occlusion of the internal cerebral artery (ICA) or middle cerebral artery (MCA). The leptomeningeal collateralisation of these patients was displayed in a dynamic fashion. Furthermore, quantitative perfusion measurement provided a difference between both MCA territories in the time to peak (deltaDTTP) of the contrast bolus of 1.12 +/- 0.28 s in five patients with severe stenosis or occlusion of the ICA (healthy volunteers 0.19 +/- 0.05 s). However, important pathological findings, such as the evaluation of carotid artery stenoses and the intracranial collateral flow pattern in patients with severe carotid stenoses, were not sufficiently assessable as compared with DSA. We conclude that the possibility of obtaining simultaneously information about morphology and perfusion dynamics of the cervicocranial vessels is unique in MPRA as compared with other MR techniques. However, in the applied form, the technique is not a reliable tool for the complete evaluation of the cervicocranial vessels in patients with steno-occlusive disease.

Adult↗

Acute appendicitis in a young adult with midgut malrotation: a case report.

Midgut malrotation is defined as a developmental anomaly that may cause atypical clinical symptoms in relatively common intestinal disorders due to altered anatomy. A 27-year-old woman presented with acute left-sided abdominal pain. Underlying type Ia malrotation prevented the correct clinical diagnosis of perforated, ulcerated appendicitis. Cross-sectional imaging demonstrated all the typical signs of this type of malrotation, i.e., right-sided duodenojejunal junction, left positioned cecum and ascending colon, inverted position of the superior mesenteric vessels, and hypoplasia of the uncinate process of pancreas, and surgical treatment was initiated.

Abdominal Pain↗

Three-dimensional dynamic MR hysterosalpingography: a preliminary report.

The aim of this study was to evaluate the feasibility of three-dimensional dynamic MR hysterosalpingography (3D MR HSG) for visualization of the cavum uteri and demonstration of bilateral fallopian tube patency as an alternative to conventional hysterosalpingography. Five infertile female patients underwent 3D dynamic MR HSG prior to conventional hysterosalpingography. The MR protocol consisted of axial T1-weighted spin-echo (SE), axial/coronal T2-weighted fast SE (FSE), and 3D MR angiography sequences before, during, and after injection of a diluted gadolinium solution into the cavum uteri via a balloon catheter. Positioning of the catheter was feasible in all patients. In one patient the catheter slipped out during MRI and in one patient the catheter was placed far in the cavum uteri. In three patients catheter position was optimal at the level of the cervical canal. Evaluation of pelvic anatomy, myometrium, and ovaries was possible in all patients on the basis of T1-weighted SE and T2-weighted FSE. Three-dimensional visualization of the dilated cavum uteri was possible in four patients. In these four patients 3D MR HSG also proved bilateral fallopian tube patency which was confirmed in each patient by conventional hysterosalpingography. Three-dimensional MR HSG is feasible and further research should be done to determine if this technique can evolve into an alternative technique to conventional hysterosalpingography with the advantages of no radiation and additional visualization of the uterus wall and ovaries.

Adult↗

Differentiation between benign and malignant findings on MR-mammography: usefulness of morphological criteria.

The purpose of this study was to evaluate the usefulness of morphological criteria in differentiating between benign and malignant lesions on MR-mammography. Fifty-three women (18-82 years) with 62 lesions scheduled for excisional biopsy underwent dynamic contrast-enhanced MR-mammography using fast 3D Gradient-Echo sequences in coronal orientation (axial orientation in seven patients). Histology revealed 44 malignant and 18 benign lesions. For each lesion, five radiologists evaluated four morphological features: lesion shape, irregularity of contour, homogeneity of contrast enhancement and presence of ring enhancement. For each feature a receiver operating characteristic (ROC) curve was generated with calculation of the area under the curve (AUC). Interobserver variability was evaluated by the kappa-coefficient. The most reliable morphological feature indicating malignancy was an irregular lesion contour with a sensitivity/specificity/AUC of 83%/76%/0.9 followed by inhomogeneous contrast enhancement (85%/42%/0.7) and the presence of ring enhancement (71%/53%/0.64). The average interobserver agreement for the different features ranged between 0.35 and 0.4. Morphological criteria are useful features in MR-mammography for differentiating between benign and malignant lesions. However, due to the relatively high interobserver variability, standardization of terminology is important.

Adolescent↗

[Percutaneous stereotactic biopsy of non-palpable breast lesions using the Advanced Breast Biopsy Instrumentation (ABBI) system: critical evaluation of indication strategies].

PURPOSE: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. MATERIAL AND METHODS: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n = 53) and masses (n = 11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. RESULTS: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. CONCLUSION: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making.

Adult↗