PubMed Health⌕ Search

Biomedical subjects

G Bonomi

Publications and source records attributed to G Bonomi.

At least 19 recordsLinked to original sources

Search for laser-induced formation of antihydrogen atoms.

Antihydrogen can be synthesized by mixing antiprotons and positrons in a Penning trap environment. Here an experiment to stimulate the formation of antihydrogen in the n = 11 quantum state by the introduction of light from a CO2 continuous wave laser is described. An overall upper limit of 0.8% with 90% C.L. on the laser-induced enhancement of the recombination has been found. This result strongly suggests that radiative recombination contributes negligibly to the antihydrogen formed in the experimental conditions used by the ATHENA Collaboration.

Journal Article↗

Evidence for the production of slow antiprotonic hydrogen in vacuum.

We present evidence showing how antiprotonic hydrogen, the quasistable antiproton (p)-proton bound system, has been synthesized following the interaction of antiprotons with the molecular ion H2+ in a nested Penning trap environment. From a careful analysis of the spatial distributions of antiproton annihilation events, evidence is presented for antiprotonic hydrogen production with sub-eV kinetic energies in states around n=70, and with low angular momenta. The slow antiprotonic hydrogen may be studied using laser spectroscopic techniques.

Journal Article↗

Measurement of the D(s)+ lifetime.

A high statistics measurement of the D(s)+ lifetime from the Fermilab fixed-target FOCUS photoproduction experiment is presented. We describe the analysis of the two decay modes, D(s)+ --> phi(1020)pi+ and D(s)+ -->K*(892)0K+, used for the measurement. The measured lifetime is 507.4 +/- 5.5(stat) +/- 5.1(syst) fs using 8961 +/- 105 D(s)+ --> phi(1020)pi+ and 4680 +/- 90 D(s)+ --> K*(892)0K+ decays. This is a significant improvement over the present world average.

Journal Article↗

New source of dense, cryogenic positron plasmas.

We have developed a new method, based on the ballistic transfer of preaccumulated plasmas, to obtain large and dense positron plasmas in a cryogenic environment. The method involves transferring plasmas emanating from a region with a low magnetic field (0.14 T) and relatively high pressure (10(-9) mbar) into a 15 K Penning-Malmberg trap immersed in a 3 T magnetic field with a base pressure better than 10(-13) mbar. The achieved positron accumulation rate in the high field cryogenic trap is more than one and a half orders of magnitude higher than the previous most efficient UHV compatible scheme. Subsequent stacking resulted in a plasma containing more than 1.2 x 10(9) positrons, which is a factor 4 higher than previously reported. Using a rotating wall electric field, plasmas containing about 20 x 10(6) positrons were compressed to a density of 2.6 x 10(10) cm(-3). This is a factor of 6 improvement over earlier measurements.

Journal Article↗

Spatial distribution of cold antihydrogen formation.

Antihydrogen is formed when antiprotons are mixed with cold positrons in a nested Penning trap. We present experimental evidence, obtained using our antihydrogen annihilation detector, that the spatial distribution of the emerging antihydrogen atoms is independent of the positron temperature and axially enhanced. This indicates that antihydrogen is formed before the antiprotons are in thermal equilibrium with the positron plasma. This result has important implications for the trapping and spectroscopy of antihydrogen.

Journal Article↗

Three-dimensional annihilation imaging of trapped antiprotons.

We demonstrate three-dimensional imaging of antiprotons in a Penning trap, by reconstructing annihilation vertices from the trajectories of the charged annihilation products. The unique capability of antiparticle imaging has allowed, for the first time, the observation of the spatial distribution of the particle loss in a Penning trap. The radial loss of antiprotons on the trap wall is localized to small spots, strongly breaking the azimuthal symmetry expected for an ideal trap. Our observations have important implications for detection of antihydrogen annihilations.

Journal Article↗

Positron plasma diagnostics and temperature control for antihydrogen production.

Production of antihydrogen atoms by mixing antiprotons with a cold, confined, positron plasma depends critically on parameters such as the plasma density and temperature. We discuss nondestructive measurements, based on a novel, real-time analysis of excited, low-order plasma modes, that provide comprehensive characterization of the positron plasma in the ATHENA antihydrogen apparatus. The plasma length, radius, density, and total particle number are obtained. Measurement and control of plasma temperature variations, and the application to antihydrogen production experiments are discussed.

Journal Article↗

Production and detection of cold antihydrogen atoms.

A theoretical underpinning of the standard model of fundamental particles and interactions is CPT invariance, which requires that the laws of physics be invariant under the combined discrete operations of charge conjugation, parity and time reversal. Antimatter, the existence of which was predicted by Dirac, can be used to test the CPT theorem-experimental investigations involving comparisons of particles with antiparticles are numerous. Cold atoms and anti-atoms, such as hydrogen and antihydrogen, could form the basis of a new precise test, as CPT invariance implies that they must have the same spectrum. Observations of antihydrogen in small quantities and at high energies have been reported at the European Organization for Nuclear Research (CERN) and at Fermilab, but these experiments were not suited to precision comparison measurements. Here we demonstrate the production of antihydrogen atoms at very low energy by mixing trapped antiprotons and positrons in a cryogenic environment. The neutral anti-atoms have been detected directly when they escape the trap and annihilate, producing a characteristic signature in an imaging particle detector.

Journal Article↗

A high statistics measurement of the Lambda(+)(c) lifetime.

A high statistics measurement of the Lambda(+)(c) lifetime from the Fermilab fixed-target FOCUS photoproduction experiment is presented. We describe the analysis technique with particular attention to the determination of the systematic uncertainty. The measured value of 204.6 +/- 3.4 (stat) +/- 2.5 (syst) fs from 8034 +/- 122 Lambda(+)(c)-->pK(-)pi(+) decays represents a significant improvement over the present world average.

Journal Article↗

Search for CP violation in the decays D+--> K(S)pi+ and D+-->K(S)K+.

A high-statistics sample of photoproduced charm from the FOCUS experiment has been used to search for direct CP violation in the decay rates for D+-->K(S)pi+ and D+-->K(S)K+. We have measured the following asymmetry parameters relative to D+-->K-pi+pi+: A(CP)(K(S)pi+) = (-1.6+/-1.5+/-0.9)%, A(CP)(K(S)K+) = (+6.9+/-6.0+/-1.5)%, and A(CP)(K(S)K+) = (+7.1+/-6.1+/-1.2)% relative to D+-->K(S)pi+. We have also measured the relative branching ratios and found Gamma(D+-->K(0)pi+)/Gamma(D+-->K-pi+pi+) = (30.60+/-0.46+/-0.32)%, Gamma(D+-->K(0)K+)/Gamma(D+-->K-pi+pi+) = (6.04+/-0.35+/-0.30)%, and Gamma(D+-->K(0)K+)/Gamma(D+-->K(0)pi+) = (19.96+/-1.19+/-0.96)%.

Journal Article↗

Measurement of the branching ratios of D(+) and D(+)(s) hadronic decays to four-body final states containing a K(S).

We have studied hadronic four-body decays of D(+) and D(+)(s) mesons with a K(S) in the final state using data recorded during the 1996-1997 fixed-target run of the Fermilab high energy photoproduction experiment FOCUS. We report a new branching ratio measurement of gamma(D(+)-->K(S)K-pi(+)pi(+))/gamma(D(+)-->K(S)pi(+)pi(+)pi(-)) = 0.0768+/-0.0041+/-0.0032. We make the first observation of three new decay modes with branching ratios gamma(D(+)-->K(S)K+pi(+)pi(-))/gamma(D(+)-->K(S)pi(+)pi(+)pi(-)) = 0.0562+/-0.0039+/-0.0040, gamma(D(+)-->K(S)K+K-pi(+))/gamma(D(+)-->K(S)pi(+)pi(+)pi(-)) = 0.0077+/-0.0015+/-0.0009, and gamma(D(+)(s)-->K(S)K+pi(+)pi(-))/gamma(D(+)(s)-->K(S)K-pi(+)pi(+)) = 0.586+/-0.052+/-0.043, where in each case the first error is statistical and the second error is systematic.

Journal Article↗

Study of the decay D0 --> K+pi-.

Using a large sample of photoproduced charm mesons from the FOCUS experiment at Fermilab (FNAL-E831), we observe the decay D0-->K+pi- with a signal yield of 149+/-31 events compared to a similarly cut sample consisting of 36 760+/-195 D0-->K-pi+ events. We use the observed ratio of D0-->K+pi- to D0-->K-pi+ (0.404+/-0.085+/-0.025)% to obtain a relationship between the D0 mixing and doubly Cabibbo suppressed decay parameters.

Journal Article↗

Modulation of TCR recognition of MHC class II/peptide by processed remote N- and C-terminal epitope extensions.

N- and C-terminal extensions of naturally processed MHC class II-bound peptides may affect TCR recognition. In fact, residues immediately flanking the minimal epitope on either side can contact the MHC groove and modify the interaction with a TCR. We report now that residues much farther away from the peptide core can also modulate TCR recognition in a functional antigen presentation system. To show this, we isolated from the same donor DR5-restricted T cell clones, specific for the HIV-1 RT(248-262) sequence and differing in their ability to respond to recombinant antigens obtained by insertion of the epitope in different positions of schistosomal, human, or murine glutathione-S-transferase (GST). We found that the reactivity profile of individual clones was related to their TCR fine specificity, suggesting that processing can generate determinants focused onto the same epitope, but antigenically distinct. In addition, we analyzed the response of this panel of T-helper cell clones against GST-derived recombinant antigens in which the epitope was flanked by stretches of polyalanine or polyserine on either side. These spacers had different effects on TCR recognition suggesting that secondary structures outside the core peptide may influence MHC/epitope complex recognition over a distance of 15-30 residues from the determinant.

Amino Acid Sequence↗

In vitro immunization with a recombinant antigen carrying the HIV-1 RT248-262 determinant inserted at different locations results in altered TCRVB region usage.

Immunodominance or cripticity of a peptide-borne determinant may be influenced by the protein context in which the epitope is embedded. In this frame, we previously showed that certain human T cell clones, derived from different donors, may differentially recognize the RT248-262 helper determinant depending on whether it is provided to the presenting cells as a synthetic peptide or as a recombinant carrier protein to which the sequence of interest is fused. We now report that, upon in vitro immunization of human PBL with autologous APC, the epitope-specific TCRVB repertoire obtained when selection is applied by pulsing the APC with the cognate synthetic peptide is different from that found when a recombinant protein is used in which the antigenic sequence is placed at either a N-terminal or C-terminal location of the GST carrier. As the TCRVB distribution is not a function of the APC used, we propose that processing of different recombinant molecules containing the same epitope may generate MHC/peptide complexes which, being antigenically diverse, may recruit distinct TCR specificities. These findings may be relevant for evaluating and predicting the immunogenic potential of subunit vaccines based on synthetic peptides or on recombinant proteins as compared to the native antigen.

Amino Acid Sequence↗

[Cystosarcoma phyllodes].

A rare case of mammary neoplasia is described. Its morphological and cytologic features are ascribed to cystosarcoma phylloides. It's a rare neoplasia since it represents only the 0.3-0.9% of mammary tumors. At present about one thousand of case have been described in literature. Because of its unforeseeable behaviour, cystosarcoma phylloides requires treatment and follow-up different from mammary carcinoma and fibroadenomas. The treatment is surgical only; the choice between an extensive exeresis and a complete mastectomy is related to tumor dimensions.

Breast Neoplasms↗

Identification of polycyclic aromatic hydrocarbons in carbon black with reference to cancerogenic risk in tire production.

Carbon blacks used in tire production have been examined for their polycyclic aromatic hydrocarbons (P.A.H.) content. The analytical procedures commonly adopted are discussed. The results obtained show that, A benzene extraction time of 250 hours is necessary to obtain complete extraction, but for practical purposes, an extraction time of 150 hours is sufficient to extract more than 95% of the PAH. It is possible to identify two classes of blacks in regard to extractables. The one class provides extractables in the range of 200--400 micrograms/g; the second class, in the range of 1000--2000 micrograms/g. No P.A.H. were detected by direct injection of carbon black into the mass spectrograph at 200 degrees C, 10(-6) torr. This was probably due to the very strong bonding to the black particles. The P.A.H. contribute a relative constant percentage of the benzene extracts. It is reasonably possible to exclude any carcinogenic risk to personnel, in a working environment, with an airborne carbon black concentration equal to or less than 3.5 mg/m3, due to the very low P.A.H. content of carbon black and to the very strong P.A.H. bonding to the black particles.

Carbon↗