PubMed HealthSearch

Biomedical subjects

G Breithardt

Publications and source records attributed to G Breithardt.

At least 19 recordsLinked to original sources

Doppler echocardiographic assessment of the pressure gradient during bicycle ergometry in hypertrophic cardiomyopathy.

To assess the behavior of the subvalvular pressure gradient under physical exercise, 13 patients with obstructive hypertrophic cardiomyopathy were examined during upright bicycle ergometry by means of Doppler echocardiography. Additionally, right-sided cardiac catheterization was performed within 7 days. In 10 patients adequate Doppler tracings could be obtained during exercise. The Doppler-derived systolic pressure gradient increased from 75 +/- 24 to 140 +/- 42 mm Hg (p less than 0.0005). This was associated with an increase in the duration of the systolic mitral-septal contact from 59 +/- 21 to 136 +/- 28 ms (p less than 0.0005). Correlation between the pressure gradient and the duration of mitral-septal contact at rest and during exercise was good (r = 0.86), whereas correlation between the resting and exercise pressure gradient (r = 0.34) did not reach statistical significance. The increase in stroke volume during exercise, from 90 +/- 18 to 95 +/- 24 ml, was significant (p less than 0.05) but minimal. Therefore, only a moderate increase in systolic flow, from 205 +/- 54 to 268 +/- 78 ml/s (p less than 0.0005), was observed. Outflow tract resistance, defined as the ratio of the pressure gradient to systolic flow, increased from 0.38 +/- 0.11 to 0.57 +/- 0.24 mm Hg.s/ml (p less than 0.01). Thus, in a selected group of patients with hypertrophic cardiomyopathy a substantial increase in the maximal pressure gradient during upright bicycle ergometry was demonstrated in most patients. Exercise Doppler echocardiography may be valuable to assess the hemodynamic significance of obstruction in individual patients in a physiologic setting and has a potential to monitor the effect of therapeutic interventions.

Adult

Thallium-201 single photon emission tomography of myocardium: additional information in reinjection studies is dependent on collateral circulation.

A second thallium-201 injection under resting conditions is able to improve the differentiation between myocardial scar and ischaemia when compared with simple redistribution imaging. The aim of this study was to evaluate the dependence of this improvement on the degree of stenosis and the presence of collaterals. Single photon emission tomography (SPET) studies under exercise, redistribution and reinjection conditions were performed on 84 patients with 181 stenotic vessels (70 left anterior descending, 47 left circumflex, 64 right coronary artery) and compared with angiography. An improvement of the 201Tl uptake in the reinjection image was observed in 53% of the myocardial areas served by a coronary artery with a stenosis of over 90%. This is compared with 13% of the areas served by a vessel with a stenosis between 50% and 90%. 90% of the collateralized areas showed a fill-in effect, but only 7 of the 118 without angiographically visible collateralization (6%). The dependence of the fill-in effect, collateralization and stenosis was highly significant (chi 2 test, p less than 0.0001). In our patient group, there was much greater benefit from the reinjection study in vessels with a greater than 90% narrowing. The fill-in effect was closely correlated to the presence of collaterals. In these cases, the fill-in may be an indication for hibernating myocardium.

Collateral Circulation

Factors which provoke post-infarction depression: results from the post-infarction late potential study (PILP).

Symptoms of depression in the majority of patients immediately following acute myocardial infarctions (AMI) resolve rapidly; they are an adjustment reaction. However, in a group of 552 male patients there were 80 (14.5%) patients with persistent major depressive symptoms during a finite period after AMI. Infarction size was assessed by maximum creatine kinase levels, the QRS-complex and the occurrence of late potentials. These measures did not correlate with the degree of depressed moods in these groups. An arrhythmic event in the early hospitalization phase, a recurrent infarction, dyspnoea, and persistent angina pectoris before the AMI were significantly related to more profound degrees of depression. Patients who reported serious life-events in the last 2 yr before AMI, or who suffered from exhaustion and fatigue in the prehospital phase were subject to significantly higher levels of depression. A prodromal phase prior to hospitalization free of bodily symptoms and the use of denial were related to low levels of depression. The logistic regression model incorporating all univariate significant variables revealed that symptoms of exhaustion and fatigue prior to AMI had the strongest independent correlation with post AMI depression.

Activities of Daily Living

Characteristics of local electrogram predicting successful transcatheter radiofrequency ablation of left-sided accessory pathways.

OBJECTIVES: The purpose of this study was to analyze and compare the local electrograms recorded at successful and unsuccessful sites of ablation to identify the criteria that may predict successful sites and minimize unnecessary radiofrequency delivery. BACKGROUND: Transcatheter ablation of accessory pathways using radiofrequency energy requires extremely precise localization of an accessory pathway. METHODS: Local electrograms from 50 consecutive patients with left-sided accessory pathways who underwent transcatheter radiofrequency ablation were analyzed. During catheter ablation, localization of accessory pathways was performed in 39 pathways during pre-excited sinus rhythm and in 14 pathways during orthodromic tachycardia. A total of 429 local electrograms at target sites obtained before delivery of radiofrequency current was analyzed. A prospective study was performed in another 20 patients using the criteria derived from the retrospective study. RESULTS: Accessory pathway conduction block was achieved in 36 (92%) of 39 pathways in which mapping was performed during pre-excited sinus rhythm and in 9 (64%) of 14 pathways in which mapping was performed during orthodromic tachycardia (p less than 0.05). When mapping was performed during pre-excited sinus rhythm, a combination of four variables (that is, an accessory pathway potential, stability of local electrograms, atrial activation greater than 1 mV and ventricular activation preceding the onset of the delta wave) showed a 62% probability of success. In contrast, excluding these variables resulted in a 95% probability of failure (noneffective or transiently effective). The prospective study shows that the use of these criteria can significantly reduce the number of current applications. When mapping was performed during orthodromic tachycardia, recording the earliest atrial activation was the most powerful predictor of success. A stable local electrogram with a small notch on the ventricular potential, presumed to be an accessory pathway potential, may add predictive value. CONCLUSIONS: Transcatheter radiofrequency ablation is highly effective in the treatment of patients with left-sided accessory pathways. Specific characteristics of local electrograms can be important predictors of success or failure. Mapping during pre-excited rhythm renders ablation more effective than does mapping during orthodromic tachycardia.

Adolescent

Prediction of the site and severity of obstruction in hypertrophic cardiomyopathy by color flow mapping and continuous wave Doppler echocardiography.

OBJECTIVE: We investigated whether the site and severity of an obstruction in hypertrophic cardiomyopathy can be accurately predicted by the combined use of color-coded and continuous wave Doppler echocardiography. BACKGROUND: Predicting the site of obstruction by end-systolic cavity shape is not reliable. Therefore, hemodynamic localization of the obstruction is required before surgery is performed. Such localization should be possible with color flow imaging, which provides two-dimensional velocity mapping reflecting the distribution of pressures within the left ventricle. Discrepancies in assessment of the pressure gradient by Doppler echocardiography and cardiac catheterization (which are usually not performed simultaneously) may be due to spontaneous variation of the dynamic obstruction in addition to technical factors related to both methods. METHODS: Twenty consecutive patients with hypertrophic cardiomyopathy were examined 1 day before transseptal left heart catheterization. The obstruction site was defined by color flow mapping. The pressure gradient was determined by continuous wave Doppler echocardiography. Measurements were also performed simultaneously in 10 patients during cardiac catheterization. RESULTS: Midventricular obstruction was correctly identified in 4 patients and subvalvular obstruction in 15 patients. One patient had no obstruction at rest. Invasively and noninvasively determined pressure gradients correlated well (r = 0.89, SEE = 16.3 mm Hg). Multiple single-beat analysis in 10 patients, also simultaneously examined with Doppler echocardiography and catheterization, yielded an excellent correlation (r = 0.97, SEE = 13.1 mm Hg). Comparing the simultaneous (r = 0.96, SEE = 12.5 mm Hg) and nonsimultaneous (r = 0.81, SEE = 23.8 mm Hg) recordings in these patients, we found that the spontaneous variation of the dynamic obstruction mainly accounted for discrepancies (p less than 0.05). CONCLUSION: The combined use of color-coded and continuous wave Doppler echocardiography provides the relevant hemodynamic information required for decision-making in patients with hypertrophic cardiomyopathy who are considered for transaortic myectomy.

Adult

Technique of aortic valve replacement with the Edwards stentless aortic bioprosthesis 2500.

Aortic valve replacement with a stentless device ought to result in superior hemodynamic function, because obstructing stents and sewing rims are eliminated. From 15 June 1991 to 15 October 1991, 15 patients underwent aortic valve replacement with the newly designed Edwards stentless aortic bioprosthesis 2500. Patients' ages ranged from 51 to 70 years (mean 61 years). Preoperatively 4 patients presented with aortic regurgitation, 7 with aortic stenosis and 4 with combined lesions; 7 patients were male and 8 female. No additional cardiac or noncardiac diseases were encountered. The operations were performed under normothermic extracorporeal cardiopulmonary bypass and cold cardioplegic cardiac arrest. The implanted valves ranged from 21 mm to 27 mm in diameter. Ten patients received a subcoronary implantation with the lower row of stitches made up of interrupted sutures and the upper row of a continuous suture. In 5 patients the so-called miniroot technique was used, also with lower interrupted sutures and running upper sutures, after adaptation of coronary ostia to the performed openings in the graft. Aortic cross-clamp time ranged between 73 min and 94 min (mean 82 min). There was no operative mortality or morbidity. Postoperative echocardiography showed no signs of aortic valve regurgation in any patient and continuous wave-Doppler measurements showed that resting pressure gradients across the aortic valve were absent or low. Our preliminary experiences with a stentless aortic xenograft valve show that in presence of an increased cross-clamp time an improved hemodynamic function will be obtained. Further studies will be needed, however, to establish the long-term behavior of this device.

Aortic Valve Insufficiency

Subthreshold electrical stimulation for termination and prevention of reentrant tachycardias.

Subthreshold electrical stimulation (STS) was used to terminate and prevent reentrant supraventricular and ventricular (VT) tachycardia. Of 12 patients with SVT, 8 had atrioventricular nodal (AVN) reentry, and 4 had orthodromic tachycardias. Trains of STS applied close to the AVN area terminated the tachycardias in five of the eight patients with AVN re-entry and two of the patients with orthodromic tachycardia. In 13 patients with recurrent sustained hemodynamically stable VT (mean cycle length 370 +/- 40 ms), trains of STS were delivered at the site of early activity during the tachycardia. Number of train cycles ranged between 3 to 8 pulses and their cycle lengths ranged between 20 and 70 ms. In 7 of the 13 patients VTs were effectively terminated by STS application close to the site of early activity and in the remaining 6 patients it did not. In nine patients the effect of STS applied at the site of early activity on VT induction from the right ventricular apex was examined. In four of the nine patients STS prevented VT induction and in the remaining five patients it did not. These observations suggest that STS applied in proximity to the area critical for initiation and maintenance of reentry can terminate or prevent induction of the tachycardia.

Adult

Nd:YAG laser-photocoagulation: acute electrophysiological, hemodynamic, and morphological effects in large irradiated areas.

Laser-photocoagulation (LPC) of arrhythmogenic myocardium has been reported to successfully ablate ventricular tachycardia. The purpose of this study was to investigate the acute hemodynamic and electrophysiological effect of continuous laser energy (Nd:YAG, 1060 nm) applied via a 0.4-mm quartz fiberoptic on the epicardial surface of the heart in nine dogs. A total of 51 +/- 2.3 pulses was delivered in each animal to induce homogeneous tissue necrosis. Applied energy was 12.3 +/- 2.7 J/mm2, irradiated surface measured 12.6 +/- 3.0 cm2, lesion depth was 6.3 +/- 1.2 mm (range: 5.0-8.1 mm), lesion volume was 8.1 +/- 2.8 cm3 (6.8% of left ventricular [LV] mass). After LPC, epicardial stimulation threshold significantly rose from 1.0 +/- 0.3 to 10.2 +/- 4.9 mA in the border zone to nontreated tissue and from 0.9 +/- 0.4 to 32 +/- 15.7 mA in the center of the lesions. Loss of epicardial activation in the irradiated areas could be demonstrated by epicardial mapping. Ventricular extrasystoles during LPC were seen in all dogs, ventricular tachycardia in seven, and ventricular fibrillation in two dogs. After LPC, cardiac output and LV dP/dtmax significantly decreased by 14.2% and 11.2%. LPC induced predictable homogeneous tissue edema, eosinophilic staining, contraction band necrosis, and sharp demarcated hemorrhagic border zones with a sharp electrical border zone to nontreated tissue and loss of epicardial activation. During LPC, various arrhythmogenic effects could be observed. However, no persistent arrhythmic activity developed after LPC. The results confirm the feasibility of epicardial LPC of the myocardium. Although not rested in this study, LPC of arrhythmogenic tissue may also be feasible as a treatment modality of ventricular tachycardia.

Animals

Radiofrequency ablation of accessory pathways: characteristics of transiently and permanently effective pulses.

The purpose of this study was to characterize and compare the radiofrequency current applications that produced permanent or transient accessory pathway conduction block. One hundred fifty-two radiofrequency energy applications that induced permanent (permanently effective pulses, n = 48) or transient (transiently effective pulses, n = 104) accessory pathway block in 57 patients with 60 accessory pathways were analyzed. The time from the onset of current application to disappearance of preexcitation or termination of supraventricular tachycardia by permanently effective pulses was 1-15 seconds (mean 3.6 +/- 3.8 sec) compared to 2-29 seconds (mean 11.5 +/- 7.5 sec) by transiently effective pulses (P less than 0.01). After transiently effective pulses that induced block in accessory pathway, conduction resumed within 5 minutes while induced block by permanently effective pulses persisted in 44 of 48 patients (92%) during follow-up of 11 +/- 12 months. The accessory pathway conduction returned in the remaining four patients after ablation 2 weeks to 7 months. After transiently effective pulses, 41 impulses were delivered to the same site using a higher power output (n = 32) and/or longer energy delivery duration (n = 20) without new mapping of accessory pathway location. Thirty-six of these impulses again resulted in transient accessory pathway block, four had no effect, only one impulse induced a permanent block in the accessory pathway. Pulses with higher power outputs tended to induce transient effects more frequently than pulses with lower energy.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Implantation of a cardioverter/defibrillator in the subpectoral region combined with a nonthoracotomy lead system.

An implantable cardioverter defibrillator was placed into a subpectoral pocket via the incision for cephalic venotomy during implantation of a nonthoracotomy lead system. The approach obviated another incision and subcutaneous tunneling of the leads. There were no perioperative complications and after 6 months of follow-up, the patient continues to tolerate the device satisfactorily.

Electric Countershock

Role of ventricular tachycardia surgery and catheter ablation as complements or alternatives to the implantable cardioverter defibrillator in the 1990s.

Although the implantable cardioverter defibrillator is used increasingly, other nonpharmacological approaches have their indications and merits. Furthermore, as the natural history of ventricular tachyarrhythmias or their underlying structural cardiac abnormality, i.e., coronary artery disease, dilated cardiomyopathy, arrhythmogenic right ventricular disease, etc. change, the mode of therapy may be modified accordingly. Because of the disappointing results of the CAST study in previously asymptomatic patients after myocardial infarction and the evidence that failure of one or two antiarrhythmic drugs tested by programmed ventricular stimulation in patients with documented sustained ventricular tachycardia or fibrillation predicts further drug failure, there will be a significant increase in the use of implantable cardioverters defibrillators in the 1990s. However, care should be taken to avoid inappropriate use of these devices.

Adult

Efficacy of antiarrhythmic drugs in patients with arrhythmogenic right ventricular disease. Results in patients with inducible and noninducible ventricular tachycardia.

BACKGROUND: Ventricular tachyarrhythmias are the major clinical manifestation of arrhythmogenic right ventricular disease. Although antiarrhythmic therapy has been widely advocated, there is only limited information available on the efficacy of antiarrhythmic drugs in these patients. METHODS AND RESULTS: The short- and long-term efficacies of various antiarrhythmic agents were retrospectively and prospectively analyzed in 81 patients (mean age, 39 +/- 14 years; range, 16-68 years; 61.7% males) with arrhythmogenic right ventricular disease. In 42 patients with inducible ventricular tachycardia during programmed ventricular stimulation, the following efficacy rates were obtained: class Ia and Ib drugs (n = 18), 5.6%; class Ic drugs (n = 25), 12%; beta-blockers (n = 8), 0%; sotalol (n = 38), 68.4%; amiodarone (n = 13), 15.4%; verapamil (n = 5), 0%; and drug combinations (n = 26), 15.4%. Only one of the 10 patients not responding to sotalol was treated effectively by amiodarone, whereas the remaining nine patients proved to be drug refractory toward all other drugs tested (3.8 +/- 2.3 drugs, including amiodarone in five cases) and underwent nonpharmacological therapy. During a follow-up of 34 +/- 25 months, three of the 31 patients (9.7%) discharged on pharmacological therapy had nonfatal recurrences of ventricular tachycardia after 0.5, 51, and 63 months, respectively. In 39 patients with noninducible ventricular tachycardia during programmed ventricular stimulation, the following efficacy rates were observed: class Ia and Ib drugs (n = 16), 0%; class Ic agents (n = 23), 17.4%; beta-blockers (n = 7), 28.6%; sotalol (n = 35), 82.8%; amiodarone (n = 4), 25%; verapamil (n = 24), 50%; and drug combinations (n = 11), 9.1%. During a follow-up of 14 +/- 13 months, four of 33 patients (12.1%) discharged on antiarrhythmic drugs had nonfatal relapses of their clinical ventricular arrhythmia. CONCLUSIONS: Thus, in arrhythmogenic right ventricular disease, sotalol proved to be highly effective in patients with inducible as well as noninducible ventricular tachycardia. Patients with inducible ventricular tachycardia not responding to sotalol are likely to not respond to other antiarrhythmic drugs and should be considered for nonpharmacological therapy without further drug testing. Amiodarone did not prove to be more effective than sotalol and may not be an alternative because of frequent side effects during long-term therapy, especially in young patients. Verapamil and beta-blockers were effective in a considerable number of patients with noninducible ventricular tachycardia and may be a therapeutic alternative in this subgroup. Class I agents appear to be rarely effective in the treatment of both inducible and noninducible ventricular tachycardia in arrhythmogenic right ventricular disease.

Adolescent

How to evaluate class III antiarrhythmic drug efficacy clinically: the benefits and shortcomings of the invasive approach.

Ventricular tachycardia and ventricular fibrillation are frequent complications of organic heart disease. There is sufficient evidence that serial electrophysiologic testing is able to predict long-term efficacy of antiarrhythmic agents in patients with malignant ventricular tachyarrhythmias. This approach has not only been useful for the evaluation of class I drugs, but recent studies have shown that this invasive method may also be useful for the management of patients undergoing treatment with class III antiarrhythmic agents such as amiodarone and sotalol. The results of several studies suggest that class III agents are more effective than class I drugs in patients presenting with ventricular tachycardia or ventricular fibrillation. Proarrhythmic complications in patients treated with class III antiarrhythmic drugs are mainly characterized by torsades de pointes. Their incidence does not exceed 5%. Further studies are necessary to elucidate the mechanisms underlying this type of proarrhythmia. By the use of currently available stimulation techniques, patients who might develop torsades de pointes while on therapy with a class III agent cannot be identified.

Amiodarone