PubMed Health⌕ Search

Biomedical subjects

G C Zucchelli

Publications and source records attributed to G C Zucchelli.

At least 73 records · Page 4Linked to original sources

External quality assurance of the carcinoembryonic antigen (CEA) assay: main findings in six years' experience.

In 1984 we initiated a national external quality assessment (EQA) program (supported by the Italian National Research Council, CNR) for the CEA assay; at present, about 200 Italian laboratories are participating in the program. The laboratories assayed the quality control (QC) samples according to their routine procedures and returned the results together with the name of the method/kit they used. The collected results were computer-processed and reports were sent back to the participants. A significant reduction of the CVt (mean between-laboratory agreement) of the CEA assay was observed throughout the EQA survey (from 35% in 1985 to 20-25% in the last cycles). In order to better clarify the differences in variability observed in the first QC cycles against the last ones, we used the ANOVA technique to evaluate the components of variability. The improvement in between-laboratory agreement was mainly due to the reduction of the between-kit component (from 30.5% to 15.2%), rather than to the smaller decrease observed for the within-kit variability (from 18.4% to 14.0%). The results reported for QC samples from different materials showed differences in the between-lab variability and substantial changes of the kit biases, thus suggesting a different specificity of the antibodies used in the various method/kits against different families of CEA molecules. Considerable uncertainty was also encountered in the clinical classification of low pathological samples, which seems mainly due to the variability in cut-off values used by the laboratories for the clinical assessment of the same analytical results. Our data indicate a progressive increase in the reliability of CEA determination during our study and confirm that EQA has improved the reliability of analysis carried out by the participating laboratories, thus stimulating the kit manufacturers to provide more reliable products.

Antibody Specificity↗

Evaluation and comparison of the analytical performances of two RIA kits for the assay of atrial natriuretic peptides (ANP).

We evaluated the analytical performance of two commercial RIA kits for the assay of plasma atrial natriuretic peptide (ANP), which use different antisera and tracers, in order to verify the most suitable RIA procedure for the assay of ANP in plasma samples. In particular, two different procedures for the purification of plasma were evaluated. The first one uses the extraction of plasma samples with Sep-Pack C18 cartridges and the second immunoextraction (C-terminal ANP-specific antibody bound to solid phase of Sepharose). The sensitivity and precision of the two RIA kits proved inadequate, being unable to provide an acceptably precise measurement of the plasma ANP concentrations in normal subjects. An improvement in precision and sensitivity was obtained by using "fresh" (or purified) preparations of the tracer and standard solutions, and by adding PEG to the B/F separation step. The direct assay (without preliminary purification) was not possible due to a serious overestimation of plasma levels due to the presence of interferences; on the other hand, the extraction step increased the imprecision and the complexity of the assay. Moreover, the extraction recovery of ANP added to plasma samples in the procedure using Sep-Pak cartridges is about 50-60%, while it was found to be almost complete (about 90%) in the immunoextraction procedure. Moreover, a comparison of the results obtained with the two RIA systems indicated that the antisera have comparable sensitivities, but quite different specificities; however, neither of the two RIA kits showed a completely satisfactory degree of sensitivity, precision and practicability.

Atrial Natriuretic Factor↗

External quality control survey for alpha-fetoprotein assay.

Starting from 1984 we organized an interlaboratory quality control (QC) survey for the tumor marker AFP in which 100-150 laboratories have been involved. Seven consecutive QC cycles have been carried out during the period 1984-1988; 15-20 samples have been prepared and sent in each cycle. The 11 kits more used in the survey, which use three different immunological methods (3 kits EIA, 3 kits RIA, and 5 kits IRMA) were evaluated. Since the results of AFP assays were expressed as ng/ml of different local standards of the various kits, the participants were asked to convert their results in UI/ml of the 1st IRP 72/225 distributed by WHO. The total variability of AFP assay resulted approximately constant (19.9-24.7 CV%) during the all QC period. The validity of the consensus mean of AFP determinations obtained in the survey and assumed as reference value has been checked by recovery experiments. Regression analysis indicates that the consensus means found in these samples are in very good agreement with the added AFP. The analytical performance achieved by the most popular methods/kits, observed in the last period, are also reported.

Italy↗