PubMed Health⌕ Search

Biomedical subjects

G C di Renzo

Publications and source records attributed to G C di Renzo.

2 recordsLinked to original sources

Fractal analysis: a new method for evaluating fetal heart rate variability.

In this report we describe how the technique of "deterministic chaos" can be successfully applied to the study of fetal cardiotocography (CTG). The CTG tracings were analysed, after identification as "normal" or "pathological" by experts and by a computerised system, to evaluate the correlation dimension (D2), and the graphic analysis of the attractors which visualize the phase-space of the system that generated the signal (of the state of the underlying hypothetical system). Thanks to this analysis of the traces, it is possible to detect the existence of chaos in the system that generates a certain signal in this case the fetal heart rate. Normal CTG traces at term (37-41 wks) show a fractal dimension (D2) index ranging from 4.22 to 5.22; highly pathological CTG tracings show a D2 ranging from 2.0 to 3.09. Moreover, we introduced recurrence plots in the study of CTG, as tool for non stationary signals, working in real time. To our knowledge this is one of the first attempts to apply fractal analysis and recurrence plots in the evaluation of fetal heart rate in pregnancy, using very small data sets.

Cardiotocography↗

Amniotic fluid amylase concentration: a reliable predictor of fetal maturity?

The amylase concentration in the amniotic fluid (ACAF) was studied in 138 subjects in relation to duration of pregnancy, fetal weight, L/S ratios and neonatal occurrence of respiratory distress syndrome (RDS). ACAF was found to be significantly correlated with duration of pregnancy (p less than 0.001) and fetal weight (p less than 0.005). The number of false immature predictions, based on a critical value of ACAF of 200 U/l, was relatively high: 36% for the gestational age greater than or equal to 36 weeks, and 38% for fetal weight greater than 2,500 g. ACAF also showed a significant relationship with the L/S ratio (p less than 0.0001). ACAF less than 300 U/l correctly predicted all instances of L/S ratio less than 2.0; however, the rate of false low predictions was 60%. In only 22 out of 138 AF samples (16%) could the performance of an L/S ratio have been avoided on the basis of the ACAF. ACAF less than 300 U/l correctly predicted both cases of neonatal RDS in the study population; however, 1 of these fetuses had an ACAF of 260 U/l. There were four times as many false predictions of lung immaturity on the basis of ACAF less than 300 U/l as from the L/S less than 2.0.

Amniotic Fluid↗