PubMed Health⌕ Search

Biomedical subjects

G Carrod

Publications and source records attributed to G Carrod.

2 recordsLinked to original sources

Human dose-response relationship for decompression and endogenous bubble formation.

The dose-response relationship for decompression magnitude and venous gas emboli (VGE) formation in humans was examined. Pressure exposures of 138, 150, and 164 kPa (12, 16, and 20.5 ft of seawater gauge pressure) were conducted in an underwater habitat for 48 h. The 111 human male volunteer subjects then ascended directly to the surface in less than 5 min and were monitored for VGE with a continuous-wave Doppler ultrasound device over the precordium or the subclavian veins at regular intervals for a 24-h period. No signs or symptoms consistent with decompression sickness occurred. However, a large incidence of VGE detection was noted. These data were combined with those from our previously reported experiments at higher pressures, and the data were fit to a Hill dose-response equation with nonlinear least-squares or maximum likelihood routines. Highly significant fits of precordial VGE incidences were obtained with the Hill equation (saturation depth pressure at which there is a 50% probability of detectable VGE [D(VGE)50] = 150 +/- 1.2 kPa). Subclavian monitoring increased the sensitivity of VGE detection and resulted in a leftward shift [D(VGE)50 = 135 +/- 2 kPa] of the best-fit curve. We conclude that the reduction in pressure necessary to produce bubbles in humans is much less than was previously thought; 50% of humans can be expected to generate endogenous bubbles after decompression from a steady-state pressure exposure of only 135 kPa (11 ft of seawater). This may have significant implications for decompression schedule formulation and for altitude exposures that are currently considered benign. These results also imply that endogenous bubbles arise from preexisting gas collections.

Adult↗

Maximum likelihood analysis of bubble incidence for mixed gas diving.

The method of maximum likelihood has been applied to predict the incidence of bubbling in divers for both air and helium diving. Data were obtained from 108 air man-dives and 622 helium man-dives conducted experimentally in a hyperbaric chamber. Divers were monitored for bubbles using Doppler ultrasonics during the period from surfacing until approximately 2 h after surfacing. Bubble grades were recorded according to the K-M code, and the maximum value in the precordial region for each diver was used in the likelihood analysis. Prediction models were based on monoexponential gas kinetics using one and two parallel-compartment configurations. The model parameters were of three types: gas kinetics, gas potency, and compartment gain. When the potency of the gases was not distinguished, the risk criterion used was inherently based on the gas supersaturation ratio, otherwise it was based on the potential bubble volume. The two-compartment model gave a significantly better prediction than the one-compartment model only if the kinetics of nitrogen and helium were distinguished. A further significant improvement with the two-compartment model was obtained when the potency of the two gases was distinguished, thereby making the potential bubble volume criterion a better choice than the gas pressure criterion. The results suggest that when the method of maximum likelihood is applied for the prediction of the incidence of bubbling, more than one compartment should be used and if more than one is used consideration should be given to distinguishing the potencies of the inert gases.

Atmosphere Exposure Chambers↗