PubMed Health⌕ Search

Biomedical subjects

G Cennamo

Publications and source records attributed to G Cennamo.

At least 19 recordsLinked to original sources

Evaluation of peripapillary detachment in pathologic myopia with en face optical coherence tomography.

BACKGROUND: A newly recognized lesion in pathologic myopia is peripapillary detachment of the retinal pigment epithelium (RPE) and retina. Recently introduced en face optical coherence tomography (OCT) provides not only cross-sectional but also coronal scans of the retina, and allows lateral extent visualization and thickness measurement of lesions. METHODS: Three patients presenting bilateral peripapillary yellow-orange lobulated area in high myopia have been evaluated with fluorescein angiography (FA), indocyanine green angiography (ICGA), en face OCT (OCT/SLO; Ophthalmic Technologies Inc, Toronto, Canada), and Humphrey visual field analyzer. RESULTS: In all eyes, en face OCT has shown the presence of a peripapillary sub-RPE nonreflective area. The lateral extent of this area was clearly detectable and the measurement of its thickness was obtained. We detected a cleft in the RPE at one edge of the cavitation in two eyes, vascular tractions and vitreoretinal tractions in two eyes, a macular hole with posterior retinal detachment, and small areas of RPE detachment nonconnected with the peripapillary detachment in one eye. In the four eyes presenting a proper central fixation, glaucomatous visual field defects were evident. CONCLUSION: En face OCT has allowed to evaluate the thickness and the lateral extent of the peripapillary detachment. Therefore, its use could be important in determining the size and grading of these lesions at first visit, and to detect minimal changes of width and thickness during follow-up as an alternative to fluorescein angiography.

Aged↗

[Intracorneal invasion of the ciliary body by melanoma].

The authors report a case of a slow reduction of vision in the left eye of a 69-year-old woman. The slit-lamp examination of the eye showed a vascularized achromic subconjunctival mass close to the nasal limbus, invading the inferonasal corneal quadrant. At B-scan and standardized A-scan echography, the mass was shown to be localized to the ciliary body, with characteristics of a malignant melanoma. The patient did not want to undergo conservative treatment. Therefore, enucleation was performed and light microscopy revealed a pigmented malignant melanoma of the ciliary body with extrascleral growth and infiltration of the anterior third of the corneal stroma. No alteration of Bowman's membrane was present. The corneal infiltration, limited to the anterior third of the stroma, could be due to the fact that at this level the collagen fibers are disposed less regularly than those of the posterior two-thirds, with this different disposition responsible for the weak resistance opposed to the tumoral invasion.

Aged↗

[Iridoschisis and angle-closure glaucoma: a case report].

INTRODUCTION: Iridoschisis is a rare condition where a localized area of iris stroma is cleaved in two, with the anterior atrophic portion disintegrating into fibrils. It is frequently associated with angle closure glaucoma and with cataract. CASE REPORT: A 70-year-old male presented with reduction of visual acuity in the left eye. Visual acuity was 20/25 OD and 20/70 OS. He had suffered acute angle-closure glaucoma in the right eye 10 years before, treated with laser iridotomy and topical antiglaucomatous therapy. Intraocular pressure was 12 mmHg OD and 46 mmHg OS. Slit lamp biomicroscopic examination revealed bilateral shallow anterior chamber, iris atrophy, and leaf degeneration of the iris stroma. A-scan and B-scan standardized echography in both eyes showed shortening of the anterior chamber, a thickened and more anteriorly located lens, the presence of a few hyperechogeneous flocculated masses floating in the vitreous, and optic disc excavation. CONCLUSION: The mechanism by which iridoschisis causes angle closure is unclear. A pupillary block could be favored by the thickening and anteriorization of the lens and the ciliary processes. Both the presence of strings of iris stroma occluding the trabecula and pupillary block could cause an elevation in intraocular pressure.

Aged↗

Echographic examination with new generation contrast agent of choroidal malignant melanomas.

PURPOSE: To determine the efficacy of echography with new generation contrast agents in visualizing vascularization of choroidal malignant melanomas. METHODS: An echographic contrast medium consisting of phospholipidic microbubbles filled with sulphur hexafluoride (Sonovue) was used to visualize microcirculation in 25 cases of choroidal lesions already diagnosed with standardized echography (21 choroidal malignant melanomas, four disciform lesions). RESULTS: In untreated malignant melanomas contrast agent echography revealed the presence of a dense microcirculation inside the mass. In one case vitreal seeding of the contrast agent was detectable before enucleation and histological examination revealed the presence of tumoral cells. In 12 cases treated with transpupillary thermotherapy, contrast agent echographic evaluation showed heavy regression of microcirculation after 1 week, confirmed in one case by histology, and a reduction of 70-80% in dimensions after 6 months (which appeared to have stabilized at subsequent examinations). In four cases treated with proton beam brachytherapy 2 years prior to our examination, contrast agent echography showed the absence of a microvascular network and the presence of large vessels and blood lakes. In four cases of disciform lesion, deep and superficial retina-associated vascularization was observed, with a weak spread of contrast agent inside the lesion. CONCLUSION: Live representation with good resolution of choroidal malignant melanoma microcirculation was obtained.

Adult↗

Clinical features of X linked juvenile retinoschisis associated with new mutations in the XLRS1 gene in Italian families.

AIMS: To describe the clinical phenotype of X linked juvenile retinoschisis in eight Italian families with six different mutations in the XLRS1 gene. METHODS: Complete ophthalmic examinations, electroretinography and A and B-scan standardised echography were performed in 18 affected males. The coding sequences of the XLRS1 gene were amplified by polymerase chain reaction and directly sequenced on an automated sequencer. RESULTS: Six different XLRS1 mutations were identified; two of these mutations Ile81Asn and the Trp122Cys, have not been previously described. The affected males showed an electronegative response to the standard white scotopic stimulus and a prolonged implicit time of the 30 Hz flicker. In the families with Trp112Cys and Trp122Cys mutations we observed a more severe retinoschisis (RS) clinical picture compared with the other genotypes. CONCLUSION: The severe RS phenotypes associated with Trp112Cys and to Trp122Cys mutations suggest that these mutations determine a notable alteration in the function of the retinoschisin protein.

Adult↗

Comparison of three fungal laccases from Rigidoporus lignosus and Pleurotus ostreatus: correlation between conformation changes and catalytic activity.

The conformation changes in solution of three fungal laccases in different environmental conditions were examined by circular dichroism (CD) and electron paramagnetic resonance (EPR) spectroscopy. CD measurements indicate that the secondary structure of proteins depends slightly on the pH or ionic strength, though the presence of salt could interfere in the molecular recognition process between substrates and enzymes. The enzymes, however, are highly destabilized by prolonged exposure to low pH or high temperature. The observed unfolding of the proteins coincides with their inactivation and, in some cases, with precipitation. On the other hand, these conditions do not determine the disruption of the geometric arrangement of their metal centres, and this fact suggests that these centres represent the more stable core of the proteins.

Catalysis↗

Purification, characterization, and functional role of a novel extracellular protease from Pleurotus ostreatus.

A new extracellular protease (PoSl; Pleurotus ostreatus subtilisin-like protease) from P. ostreatus culture broth has been purified and characterized. PoSl is a monomeric glycoprotein with a molecular mass of 75 kDa, a pI of 4.5, and an optimum pH in the alkaline range. The inhibitory profile indicates that PoSl is a serine protease. The N-terminal and three tryptic peptide sequences of PoSl have been determined. The homology of one internal peptide with conserved sequence around the Asp residue of the catalytic triad in the subtilase family suggests that PoSl is a subtilisin-like protease. This hypothesis is further supported by the finding that PoSl hydrolysis sites of the insulin B chain match those of subtilisin. PoSl activity is positively affected by calcium. A 10-fold decrease in the K(m) value in the presence of calcium ions can reflect an induced structural change in the substrate recognition site region. Furthermore, Ca(2+) binding slows PoSl autolysis, triggering the protein to form a more compact structure. These effects have already been observed for subtilisin and other serine proteases. Moreover, PoSl protease seems to play a key role in the regulation of P. ostreatus laccase activity by degrading and/or activating different isoenzymes.

Amino Acid Sequence↗

Protein and gene structure of a blue laccase from Pleurotus ostreatus1.

A new laccase isoenzyme (POXA1b, where POX is phenol oxidase), produced by Pleurotus ostreatus in cultures supplemented with copper sulphate, has been purified and fully characterized. The main characteristics of this protein (molecular mass in native and denaturing conditions, pI and catalytic properties) are almost identical to the previously studied laccase POXA1w. However, POXA1b contains four copper atoms per molecule instead of one copper, two zinc and one iron atom per molecule of POXA1w. Furthermore, POXA1b shows an unusually high stability at alkaline pH. The gene and cDNA coding for POXA1b have been cloned and sequenced. The gene coding sequence contains 1599 bp, interrupted by 15 introns. Comparison of the structure of the poxa1b gene with the two previously studied P. ostreatus laccase genes (pox1 and poxc) suggests that these genes belong to two different subfamilies. The amino acid sequence of POXA1b deduced from the cDNA sequence has been almost completely verified by means of matrix-assisted laser desorption ionization MS. It has been demonstrated that three out of six putative glycosylation sites are post-translationally modified and the structure of the bound glycosidic moieties has been determined, whereas two other putative glycosylation sites are unmodified.

Amino Acid Sequence↗

Goldmann applanation tonometry after myopic photorefractive keratectomy.

PURPOSE: To determine the accuracy of applanation tonometry in patients with corneas thinned by photorefractive keratectomy, and to correlate corneal changes with tonometric readings. METHODS: The intraocular pressure was measured with Goldmann applanation tonometry in 87 patients who underwent photorefractive keratectomy before and 1, 6 and 12 months after treatment. The treatments ranged from -1.5 to -14 diopters (mean=-7.6+/-4.1 diopters) and the fellow eyes were used as controls. RESULTS: In the treated eyes the intraocular pressure before surgery ranged from 11 to 26 mmHg (mean=17.7+/-2.8 mmHg). One month after surgery it ranged from 5 to 22 mmHg (mean=11.9+/-2.7 mmHg) with a significant underestimation (P=1x10(-33)). Six months after surgery it ranged from 6 to 22 mmHg (mean=12+/-3 mmHg) with a significant underestimation (P=5x10(-30)). Twelve months after surgery it ranged from 8 to 22 mmHg (mean=12.7+/-2.7 mmHg) with a significant underestimation (P=5x10(-31)). CONCLUSIONS: A correcting factor should be applied when using applanation tonometry to measure intraocular pressure in patients who have undergone PRK.

Adolescent↗

In vitro evaluation of a new echographic contrast agent.

BACKGROUND: So far, intravenously injected echographic contrast agents have not been able to overcome the lung circle, and their use was confined to the study of right-sided heart abnormalities. A new agent that is able to pass the pulmonary barrier has been manufactured, and it is currently under investigation in ophthalmology. METHODS: A saccharide-based contrast agent (SHU 454) that is not able to overcome the lung filter has been compared in vitro with a new saccharide-based contrast agent (SHU 508 A) that is able to overcome the pulmonary barrier. They have been diluted in saline solution, and the reflectivity of the solution and the eventual sound attenuation have been studied with standardized A scan and a tissue model. RESULTS: The solution with SHU 508 showed a higher reflectivity that lasted longer, without significant sound attenuation. CONCLUSIONS: The long-lasting period of the increased reflectivity will allow to better evaluate the normal and pathological vascular network in the eye and orbit, such as the evaluation of the effectiveness of conservative treatment in cases of malignant melanoma with a spread of the indications of standardized echography to other fields of ophthalmology.

Contrast Media↗

Power doppler ultrasonography in ocular and orbital diseases.

PURPOSE: The authors present a preliminary report to test the usefulness of a new technique called power Doppler ultrasonography (PD) in the study of orbital vessels. MATERIAL AND METHODS: The ophthalmic artery and vein as well as the central retinal artery and vein have been examined in 10 patients with a General Electric Logiq 5000 that allows the examination with both color Doppler ultrasonography (CD) and PD. RESULTS: PD does not alias, is relatively angle independent and is able to better detect the pathways of these vessels. CONCLUSIONS: PD is a new promising technique that may be superior to CD in detecting orbital and ocular vessels.

Blood Flow Velocity↗

The corneal endothelium 12 months after photorefractive keratectomy in high myopia.

PURPOSE: To determine if photorefractive keratectomy with a 193 nm excimer laser could cause human corneal endothelial changes, mainly in high dioptric treatments. METHODS: 18 patients underwent a treatment ranging from 7 to 13 diopters at the corneal apex (mean 10.3 +/- 1.4 SD) with an estimated corneal thinning ranging from 62 to 116 microns (mean 90.7 +/- 12 SD). In these patients a comparison between the number and shape of the corneal endothelial cells has been performed before and 12 months after PRK. RESULTS: The mean cell density was 2818 +/- 337 mm2, before surgery, and 2894 +/- 301 mm2 after 12 months. The polymorphic index was 79.0 +/- 2.3, before surgery, and 81.0 +/- 5.0 after 12 months with no significant changes (p = 0.16 and P = 0.09, respectively). CONCLUSIONS: These results show that photorefractive keratectomy does not cause any significant observable damage to the central corneal endothelium up to 12 months after surgery, even in high myopic treatments.

Adult↗

Use of a special device for the treatment of overfiltration after glaucoma filtering surgery.

BACKGROUND: standardized A and B scan echography were used to look for the possible presence of ciliochoroidal detachment in patients with flat anterior chamber following glaucoma filtering surgery. For this purpose, a scleral shell filled with saline solution was inserted between the lids. As a deepening of the anterior chamber was found in some patients, we planned to utilize these devices for the treatment of flat anterior chambers after glaucoma filtering surgery. METHODS: 16 patients with flat anterior chambers after glaucoma filtering surgery underwent the insertion of a scleral shell filled with saline solution between the lids. The shell was left in place for 15 min. RESULTS: In all of our patients a deepening of the anterior chamber was achieved. In 5 patients 1 application, in 6 patients 2 applications, in 4 patients 3 applications were needed. CONCLUSIONS: The advantages of using this procedures are: the procedure is quick; it does not disturb the corneal epithelium; it is cheap; it does not require suturing the conjunctiva; it can be part of the examination of the anterior segment with echography to look for any ciliary body detachment.

Anterior Chamber↗

Non-contact tonometry in patients that underwent photorefractive keratectomy.

To determine the accuracy of non-contact tonometry in patients with corneas thinned by photorefractive keratectomy, the authors measured the intraocular pressure with a non-contact tonometer and the corneal thickness with an ultrasonic pachymeter in 47 patients before and 9 months after photorefractive keratectomy. The patients were divided into three groups according to the degree of treatment: group I between 1 and 5 diopters (14 eyes), group II between 6 and 10 diopters (18 eyes), group III between 11 and 15 diopters (15 eyes). In the first group of patients mean intraocular pressure was 16.1 (+/-3.85) mm Hg before surgery, and 13.2 (+/-3.14) mm Hg after surgery with a significant difference (p = 0.0027). In the second group of patients mean intraocular pressure was 16.0 (+/-4.13) mm Hg before surgery and 13.0 (+/-3.0) mm Hg after surgery with a significant difference (p = 0.0045). In the third group of patients mean intraocular pressure was 17.7 (+/-3.8) mm Hg before surgery and 12.4 (+/-2.6) mm Hg after surgery, with a significant difference (p = 0.0005). In conclusion, according to our results, non-contact tonometry needs a correcting factor for measuring the intraocular pressure in patients that underwent photorefractive keratectomy, related to the degree of refractive treatment.

Adult↗