PubMed Health⌕ Search

Biomedical subjects

G Cianciolo

Publications and source records attributed to G Cianciolo.

At least 19 recordsLinked to original sources

Molecular adsorbent recirculating system (MARS) application in liver failure: clinical and hemodepurative results in 22 patients.

PURPOSE: Acute liver failure (ALF) and acute on chronic liver failure (ACLF) still show a poor prognosis. MARS was used in 22 patients with ALF or ACLF to prolong patient survival for liver function recovery or as a bridge to transplantation. DESIGN: Evaluation of depurative efficiency, biocompatibility, hemodynamics, encephalopathy (HE) and clinical outcome. PROCEDURES: During 71 five-hour sessions we evaluated (0', 60', 120', 180', 240', 300'): bilirubin, ammonia, cholic acid (CCA), chenodeoxycholic acid (CCDCA), leukocytes, platelets, hemoglobin and mean arterial pressure (MAP). Serum creatinine, electrolytes, cardiac output, cardiac index (bioimpedence) and HE (West Haven Criteria score) were evaluated at 0' and 300'. STATISTICAL METHODS AND OUTCOME MEASURES: Student's t-test for pre- vs. end-session values was used. For bilirubin and ammonia the correlation test was made between pre- and end-session values and between pre-session values and removal rates (RRS). MAIN FINDINGS: Survival was 90.9% at 7 days, 40.9% at 30 days. Pre- vs. end-session: bilirubin from 37.2 +/- 12.5 mg/dL to 24.9 +/- 8.9 mg/dL (p < 0.01), ammonia from 88.0 +/- 60.4 micromol/L to 43.6 +/- 32.9 micromol/L (p < 0.01), CCA from 42.8 +/- 21.0 micromol/L 18.2 +/- 9.8 micromol/L (p < 0.01), CCDCA from 26.3 +/- 6.3 micromol/L to 15.7+/-7.6 micromol/L (p<0.01). The correlation test between pre-session values of bilirubin and ammonia vs. RR S was respectively 0.32 (p = 0.01) and 0.30 (p = 0.04). Leukocytes, platelets and hemoglobin remained stable. MAP increased from 82.0 +/- 12.0 mmHg to 87.0 +/- 13.0 mmHg (p < 0.05), West Haven Criteria score decreased from 2.7 +/- 0.7 to 0.7 +/- 0.7 (p < 0.001). CONCLUSION: MARS treatment led in all patients to an improvement of clinical, hemodynamic and neurological conditions, with significant reduction in the hepatic toxins blood level. Treatment biocompatibility and tolerance were satisfactory.

Acute Kidney Injury↗

Artificial kidney: status of the art and new perspectives.

Extracorporeal dialysis was first performed in 1943 and has become a routine for End Stage Renal Patients from the early sixties. In the last 30 years researchers have focused on biocompatibility of artificial materials and optimisation of removal of uremic toxins by the membrane as in the long term treatment many complications like amylodosis heart and bone lesions, accelerated amyloidosis and immune system failure can occur. From this point of view high flux dialytic membranes are currently considered more biocompatible therefore being able to prevent such diseases.

Biocompatible Materials↗

Inflammatory response of a new synthetic dialyzer membrane. A randomised cross-over comparison between polysulfone and helixone.

Hemodialysis patients suffer from chronic inflammation due to intradialytic contact of blood with artificial materials. The FX 60 dialyzer which belongs to the new FX-class series of dialyzers is composed of the new membrane Helixone. This membrane is derived from the original Fresenius Polysulfone membrane. The FX-class design is based on modified geometry of fibres and housing and has resulted in a new dialyzer with improved efficiency, safety and ease of handling compared to the F series (F 60S) dialyzer. The aim of the study was to investigate whether the biocompatibility pattern in terms of inflammatory parameters of the new type of polysulfone dialyzer has changed compared to the standard. A clinical in vivo study was conducted to compare the intradialytic inflammatory response of the two dialyzers, FX 60 and F 60S. Eight chronic dialysis patients were selected for the study: mean age 65.5 +/- 15.5 years, mean time on dialysis 100 +/- 95 months. The randomized cross-over study involved a treatment period of 2 weeks (total 6 sessions), one week with each dialyzer, starting with one or the other according to the randomization scheme. Blood samples were taken at 0 (T0), 15, 60, and 240 minutes to evaluate white blood cell (WBC) count, complement factor C5a, leukocyte elastase, soluble intercellular adhesion molecule 1 (sICAM-1), platelet count, C-reactive protein (CRP). At 15 min, WBC count showed a comparably, low decrease for both dialyzers: -7.6% for FX 60 versus -6.6% for F 60S, p=not significant (ns). At the same time the C5a concentration decreased from 15.0 +/- 7.5 ng/ml to 13.5 +/- 6.7 ng/ml (p=ns) for FX 60, and from 15.1 +/- 12.5 ng/ml to 14.9 +/- 25.0 ng/ml for F 60S (p=ns). The elastase concentration progressively increased over time with no statistical difference between the two dialyzers. The levels of sICAM-1, CRP, and platelet count were similar at each time point for both dialyzers, varying around the baseline values (p=ns). No significant difference emerged in terms of inflammatory response between the two dialyzers, hemo demonstrating that the biocompatibility of the F-series was maintained in the FX-class series of dialyzers and is independent of design factors.

Aged↗

Clinical application of sodium profiling in the treatment of intradialytic hypotension.

BACKGROUND: Intradialytic hypotension is mainly induced by the removal of extracellular sodium during dialysis, which impairs intravascular fluid refilling and reduces blood volume. To counter this complication we tested a new kind of profiled hemodialysis (PHD) consisting of the intradialytic modulation of dialysate sodium concentration according to individual profiles set up using a new mathematical model for intradialytic solutes and water kinetics. The clinical aim of this PHD is to stabilize blood pressure maintaining higher blood volume values than standard dialysis treatments. We clinically validated PHD in comparison with constant dialysate sodium dialysis (CHD). METHODS: Twenty hypotensive dialysis patients underwent one PHD and one CHD session maintaining the same dialysis length, sodium mass removal and body weight decrease. A new mathematical model was used to define both the dialysate sodium profiles for PHD and the constant dialysate sodium for CHD. Percent blood volume variation (Crit-line), mean blood pressure, heart rate, cardiac output (Doppler-echocardiography) were monitored intradialitically. RESULTS: Cardiovascular stability improved on PHD as compared with CHD sessions; blood volume and cardiac output during PHD showed a lower decrease than on CHD, the differences statistically significant (from 30' and 60' respectively). Mean blood pressure was, at all time intervals, more stable on PHD than on CHD and was accompanied, on PHD, by a lower heart rate increase (differences statistically significant). CONCLUSIONS: This study shows that PHD performed using dialysate sodium profiles elaborated by our mathematical model obtains, in hypotensive patients, a higher hemodynamic intradialytic stability than CHD, probably due to a higher stabilization of blood volume.

Aged↗

Platelet activation and PDGF-AB release during dialysis.

During hemodialysis the blood-membrane contact causes a release of platelet granule content, which contains Platelet Derived Growth Factor (PDGF-AB). In view of its possible role in accelerated atherosclerotic processes, we evaluated the intra- and post-dialytic changes in PDGF-AB serum levels during hemodialysis sessions performed with Hemophan and Polysulfone membranes. PDGF-AB, PF4, betaTG and MPV levels were determined in the peripheral blood in 30 patients each of whom underwent 6 dialysis sessions: 3 with Hemophan (HE) membrane and 3 with Polysulfone (PS) membrane, interpolated by a wash out session with PS membrane. Blood samples were taken at times 0', 30', 120', 180', 240' during dialysis sessions and at 1, 4 and 20 hours after the end of the session. Statistical analysis was done using the ANOVA one way test and Student's t test PDGF-AB serum levels initially increased and, except for a sharp fall at 120', remained constantly high during HD with both membranes tested, not returning to basal values until 20 hours after the end of the session. PF4, betaTG and MPV all showed a similar trend to PDGF. No statistically significant difference was found between the two membranes tested. PDGF-AB, a powerful growth factor in cells of mesenchymal origin, is released during dialysis mainly as a result of the blood-membrane contact. This we found regardless of the type of dialyzer we tested, and, above all, proved to return very slowly to basal values. We speculate that the release of PDGF-AB could play a part like other atherosclerosis risk-factors in the appearance and worsening of atherosclerotic lesions in hemodialysis patients.

Aged↗

Inducible expression of the alpha2-macroglobulin signaling receptor in response to antigenic stimulation: a study of second messenger generation.

Thioglycollate (TG)-elicited murine, peritoneal macrophages express two receptors for activated forms of the proteinase inhibitor alpha2-macroglobulin (alpha2M*)--namely, the low density lipoprotein receptor-related protein (LRP) and the alpha2M signaling receptor (alpha2MSR). We now report that resident peritoneal macrophages express only 400+/-50 alpha2MSR receptors/cell compared to 5000+/-500 receptor/TG-elicited macrophage. By contrast, LRP expression is only 2-2.5-fold greater on elicited cells. The low level of alpha2MSR expression by resident cells is insufficient to trigger signal transduction in contrast to TG-elicited cells which when exposed to alpha2M* demonstrate a rapid rise in inositol 1,4,5-trisphosphate and a concomitant increase in cytosolic free Ca2+. We then studied a variety of preparations injected subcutaneously for their ability to upregulate alpha2MSR. Macroaggregated bovine serum albumin (macroBSA) injection upregulated alpha2MSR and triggered signaling responses by splenic macrophages. Nonaggregated BSA injection alone or in the presence of alum, by contrast, did not alter alpha2MSR expression. Recombivax (hepatitis B antigen adsorbed to alum) injection also upregulated alpha2MSR on splenic macrophages while the alum carrier had no effect. We conclude that macrophage alpha2M* receptors are inducible and their expression may be regulated, in part, by potential antigens.

Adjuvants, Immunologic↗

Intra- and post-dialytic platelet activation and PDGF-AB release: cellulose diacetate vs polysulfone membranes.

BACKGROUND: During haemodialysis the blood-membrane contact causes a release of platelet granule content, which contains platelet-derived growth factor AB (PDGF-AB). In view of the potential role of this in altering biocompatibility during haemodialysis, we evaluated the intra- and post-dialytic changes in PDGF-AB serum levels during haemodialysis sessions performed with cellulose diacetate (CDA) and polysulfone (PS) membranes respectively. METHODS: PDGF-AB, platelet factor 4 (PF4), beta thromboglobulin (betaTG), and mean platelet volume (MPV) levels were determined in 30 patients, each of whom underwent six dialysis sessions: three with a CDA and three with a PS membrane. Blood samples were taken at times 0, 15, 30, 120, 180, and 240 min during dialysis and at 1, 4, and 20 h after the end of the session. Statistical analysis was performed using a one-way ANOVA and Student's t test. RESULTS: PDGF-AB at 15 min was increased to +41+/-9% with CDA vs +20+/-5% with PS (P<0.001) from the T0 values, and at 120 min it was +19+/-8% with CDA vs -25+/-9% with PS (P<0.001) from T0 levels. At 240 min it was +95+/-14% with CDA vs +49+/-15% with PS (P<0.001) from the T0 values, returning to basal only 20 h after the end of the session. betaTG at 15 min was +60+/-8% for CDA vs +24+/-7.5% for PS (P<0.001) from the T0 values. PF4 showed a similar trend to betaTG. MPV at 30 min from the start of dialysis was 7.4+/-0.3 fl with CDA and 8+/-0.3 fl with PS (P<0.001), and at 240 min MPV was 7.9+/-0.3 fl with CDA and 8.4+/-0.3 fl with PS (P<0.001). CONCLUSIONS: Platelet activation and platelet release reactions are lower with PS than with CDA membranes. PDGF-AB, released during and after dialysis, represents a clear biocompatibility marker. Its slow return to basal values and its action on vascular cells make it a potential risk factor for atherosclerosis in uraemic patients.

Biocompatible Materials↗

Evaluation of intradialytic solute and fluid kinetics. Setting Up a predictive mathematical model.

A mathematical model of solute kinetics for the improvement of hemodialysis treatment is presented. It includes a two-compartment description of the main solutes and a three-compartment model of body fluids (plasma, interstitial and intracellular). The main model parameters can be individually assigned a priori, on the basis of body weight and plasma concentration values measured before beginning the session. Model predictions are compared with clinical data obtained in vivo during 11 different hemodialysis sessions performed on 6 patients with a profiled sodium concentration in the dialysate and a profiled ultrafiltration rate. In all cases, the agreement between the time pattern of model solute concentrations in plasma and the in vivo data proves fairly good as to urea, sodium, chloride, potassium and bicarbonate kinetics. Only in two sessions was blood volume directly measured in the patient, and in both cases the agreement with model predictions was good. In conclusion, the model allows a priori computation of the amount of sodium removed during hemodialysis, and makes it possible to predict the plasma volume changes and plasma osmolarity changes induced by a given sodium concentration profile in the dialysate and by a given ultrafiltration profile. Hence, it can be used to improve clinical tolerance to the dialysis session taking the characteristics of individual patients into account, in order to minimize intradialytic hypotension.

Bicarbonates↗

PDGF-AB release during and after haemodialysis procedure.

BACKGROUND: During haemodialysis blood membrane contact causes the release of the content of platelet alpha-granules, which contain platelet-derived growth factor (PDGF). In view of its possible role in accelerated atherosclerotic processes, we evaluated the intra- and post-dialytic changes in PDGF-AB serum levels during haemodialysis sessions performed using a cellulosic membrane. METHODS: Using the ELISA method, PDGF-AB, platelet factor-4 (PF4) and beta-thromboglobulin (beta-TG) levels were determined in peripheral blood, as well as in arterial and venous haemodialyser lines, in 10 patients each of whom underwent five consecutive dialysis sessions with a CU membrane. Blood samples were taken at 0, 15, 30, 60, 120, 180 and 240 min during dialysis and at 1, 4 and 20 h after the end of the session. In the same group of patients the levels of the same molecules were also determined after a heparin bolus injection of 4500 IU, blood samples were taken at 0, 15 and 30 min after injection of the bolus. RESULTS: PDGF-AB serum levels increased, remained consistently high during the haemodialysis session (in particular +134+/-20% after 30 min, P<0.001, and +140+/-5% after 240 min, P<0.001) and returned to basal values only after 20 h following the end of the session. PF4 and beta-TG showed a similar trend to PDGF. The heparin bolus injection caused only a small increase (+15+/-5% at 30 min) in PDGF-AB serum levels. CONCLUSIONS: PDGF-AB is released during dialysis mainly as consequence of the blood-membrane contact and it returns only slowly to basal values.

Adult↗

Effect of different dialysis membranes on platelet function. A tool for biocompatibility evaluation.

Intradialytic coagulative and platelet activation, one of the main consequences of blood-membrane contact, was studied in a group of 5 RDT patients with a comparative evaluation of 3 different dialytic membranes: Cuprophan (CU), Polysulfone (PS) and Cellulose Triacetate (CT). Each patient underwent 5 consecutive dialysis sessions with the above mentioned membranes. Intradialytic platelet activation was studied through a morpho-functional evaluation between the mean platelet volume (MPV) and Serotonin (S), beta-Thromboglobulin (beta-TG) and Platelet Factor 4 (PF4) serum levels. These determinations were made before HD (time 0) and after 30', 120', and 240'. We also checked the intradialytic status of thrombogenesis and fibrinolysis determining aPTT, thrombin time, fibrinogen, antithrombin III (AT III), alpha-2 antiplasmin and plasminogen, at the same time intervals. All membranes tested (CU, PS, CT) caused appreciable intradialytic platelet activation, above all after 15' and at the end of dialysis sessions, more marked for CU than PS or CT. In particular MPV showed a decrease throughout the session (-5% at 30' and -9% at 240') while S, beta TG and PF4 peripheral blood levels showed a significant increase at the same intervals with CU membrane. Lastly coagulative and fibrinolytic parameters showed no significant differences among any of the membranes tested.

Adult↗

Hemoperfusion in chronic uremia.

Hemoperfusion is a blood purification technique involving direct contact between blood and adsorbent substances (sorbents). There are three basic kinds of sorbent: activated charcoal, immunoadsorbents, resins. Following our previous experience on charcoal hemoperfusion, a new coated anionic exchange resin for blood purification specifically designed to remove phosphates was experimentally employed in animals. 3 pigs, in which uremia had been surgically induced, underwent 6 extracorporeal hemoperfusion sessions (2 per pig) with a cartridge containing 100 gr of resin. The phosphate clearance proved satisfactory, values being 120 ml/min after 10' and around 80 ml/min after 2 hours. The biocompatibility of the resin and of the coating membrane was satisfactory. The negligible variation in pH and plasma bicarbonate during all sessions confirmed the low absorption by the tested resin of other blood anions competing with phosphate.

Animals↗

Strategies in renal failure and the impact of lipids.

The main points to note in terms of strategies in renal failure and the impact of lipids are: 1) Timing and typing of dyslipidemia; 2) Occurrence of dyslipidemia in the course of strategies (conservative, dialysis and transplantation); 3) How the strategies can handle the impact of lipids. Analysis of point 1 confirms what a complex profile uremic dyslipidemia presents, involving the type, class, composition and enzyme systems involved in lipid metabolism. In conservative and dialysis, type IV (triglycerides) predominates; in transplantation, type II (cholesterol). Examination of point 2 shows the non obligatory relationship between dyslipidemia and the various strategies of treatment. Lipid abnormalities, type IV or II, occur in 50-60% of patients. Uremic factors for dyslipidemia include: 1) enhanced hepatic stimulation or altered removal in conservative strategies; 2) the same causes plus "specific" promotors in dialysis (dialysis fluid, plasticizer leaching; bioincompatibility, etc.); 3) steroid therapy and other "accessories" in transplantation. A genetic predisposition is very likely present in all patients. Point 3, finally, analyzes the various "supplements" that each strategy requires to cope with the lipid impact. Generic rules (ranging from doing nothing, to diet, drugs, etc.) are of value in all strategies when dyslipidemia occurs. More specific rules include: a) Conservative strategies: appropriate dietetic optimization and modulation (protein-lipid-carbohydrate ratio in terms of calories); b) Dialysis: timing treatment and improving biocompatibility; c) Transplantation: reducing steroids as much as possible.

Humans↗

Value of panel reactive antibodies (PRA) as a guide to the treatment of hyperimmunized patients in renal transplantation.

Patient presensitization represents a considerable problem in candidacy for renal transplantation. While it is well known that hyperimmunized patients--panel reactive antibody (PRA) higher than 60%--create difficulties in donor matching and have a worse outcome than non-hyperimmunized patients, less information is available on patients with an intermediate degree of sensitization (30-60%). In order to evaluate how graft outcome relates to such degrees of sensitization, 241 consecutive transplanted patients were divided into two groups on the basis of their previous year's PRA peak: group A, PRA 0-29%; group B, PRA 30-60%. Group A showed a significantly better survival both in the first year (90% vs 79%, P < 0.05) and in the third year (82% vs 64%, P < 0.01). However, detailed analysis of group B demonstrated that some parameters may significantly influence graft outcome: (1) better compatibility on locus DR; (2) a primary kidney transplant; (3) a dialysis duration of less than 6 months; and (4) the prophylactic use of antilymphocyte globulin (ALG).

Adolescent↗

Application of flow cytometry in clinical renal transplantation.

Flow cytometry (FC) may be considered as a fundamental technique in studying cell biology and pathology. It combines the quantitative character of biochemical methods with the multiparametric capacities of microscope analysis in a high-precision process for rapid analysis of individual cell characteristics. Three original FC techniques routinely applied in the field of renal transplantation are reported in the present study. They concern the donor-recipient cross-match test, the morphological analysis of urinary sediment and the modulation of the density of various membrane antigens on the lymphocyte surface. A common factor underlies all these methods: they aim to provide the physician with a reliable diagnostic tool in clinical renal transplantation.

Antigens, Surface↗