PubMed Health⌕ Search

Biomedical subjects

G Colasanti

Publications and source records attributed to G Colasanti.

44 records · Page 3Linked to original sources

Continuous urea monitoring in hemodialysis: a model approach to forecast dialytic performance. Results of a multicenter study.

BACKGROUND: A urea biosensor, inserted into the ultrafiltrate collection-line of paired filtration dialysis (PFD), not only allows on-line dialysis quantification, but also forecasts final (Cend) and 30 min equilibrated urea concentration (Ceq), the most reliable value for calculating dialysis efficiency. The urea biosensor processes plasma ultrafiltrate continuously, delivering a large amount of data to the computer, which estimates the parameters by a mathematical model, thus predicting the whole urea profile with rebound. METHODS: A multicenter randomized trial on 41 patients was conducted to ascertain the ability of a two-pool variable-volume urea model to forecast Cend and Ceq at 60 and 90 min after the start of dialysis. Two alternative dialytic treatments, A or B, were chosen, the latter being more efficient. Each treatment included six serial PFD. The accuracy of forecasting was evaluated through four indices based on forecast errors, calculated as the difference between observed and forecasted urea values: mean percent error (MPE) (%), mean absolute deviation (MAD) (mg/dl), mean absolute percent error (MAPE) (%) and root mean squared error (RMSE) (mg/dl). RESULTS: Forecasted urea concentrations were lower than those measured by the biosensor. MPE for Cend was negligible in A (+1.2%) and much higher in B (+7.2%); both values improved at 90 min, +1.0% and +5.8%, respectively. MAD for Cend was similar in both treatments and improved slightly at 90 min, ranging from 4.9 to 5.9 mg/dl. MPE for Ceq was +4% in A and and more than doubled in B (+11.5%); both values improved at 90 min, +3.7% and +9.7%, respectively. MAD for Ceq was 7.5 mg/dl in A and 8.5 mg/dl in B; both improved at 90 min, 6.7 and 7.4 m g/dl, respectively. The other indices, MAPE and RMSE, showed similar results. Comparison between the errors of the two treatments with analysis of variance (ANOVA) for repeated measures gave no significant results. CONCLUSIONS: Our model forecasts of urea concentrations were overall lower than the measured ones: the bias was negligible for A-Cend, greater for the A-Ceq and when the more efficient treatment B was used. The 60 min predictions improved at 90 min. The comparison between the prediction errors in the two treatments were not statistically significant. The recirculation measurement would probably reduce the bias if it were properly incorporated into the model.

Filtration↗

[Italian Registry of Dialysis and Transplantation: 1996-2001 experience].

The Italian Registry of Dialysis and Transplantation (RIDT) was born in 1996 under the aegis of the Italian Society of Nephrology, and it is organized as a federation of regional registries. This study aimed to completely revise the epidemiological data collected during the first 5 yrs (1996-2001) of RIDT activity to evaluate the trends of the main epidemiological features. During this period, regional registries were not always able to assure complete and exhaustive information according to RIDT requirements, owing to different levels of organization and functioning. To avoid any possible error in data analysis, information inadequately assessed was refused. The incidence of end-stage renal disease (ESRD) patients on renal replacement therapy (RRT) in Italy has increased from 114 pmp in 1996 to 139 pmp in 2001, that means an increase of 3.5%/yr, corresponding to 5718 patients during 1996 and 8000 patients during 2001. Primary renal diseases (according to the EDTA) in incident ESRD patients are vascular and diabetic nephropathy. Main dialysis modality in incident patients was hemodialysis (HD) (85%), while peritoneal dialysis (PD) was only 15%; pre-emptive transplantation was a very unusual modality. The prevalence of ESRD patients at 31 December was 693 pmp in 1996 and 827 pmp in 2001; among dialysis patients, the corresponding rates were 575 pmp and 657 pmp, respectively. Consequently, the number of dialyzed patients increased, respectively, from 28892 to 37919. The prevalent dialysis modality was bicarbonate dialysis in 74% of cases, followed by hemodiafiltration (HDF) in 15%, continuous ambulatory peritoneal dialysis (CAPD) in 7% and APD in 3%. The gross mortality rate in dialyzed patients was stable during this period, at approximately 14%, the main causes of death being cardiovascular diseases and cachexia.

Adolescent↗

[Alterations of cardiac output during bicarbonate hemodialysis and its relationship with other hemodynamic parameters].

PURPOSE: Time course of cardiac output (CO) and other hemodynamic parameters were measured during hemodialysis (HD). Our aims were to identify a characteristic CO profile and investigate the relationship with other hemodynamic parameters. PATIENTS AND METHODS: CO was measured with ultrasound dilution method in 45 chronic hemodynamically stable HD patients. Diabetics and patients with heart diseases were excluded. Ultrafiltration rate (UFR) was fixed at 649 +/- 244 mL/min. Pre/post statistical comparisons were performed for CO, cardiac index (IC), central blood volume (CBV) and total peripheral resistance (TPR). RESULTS: CO was pre 5.7 +/- 1.8 and post 4.5 +/- 1.4 L/min (p=0.001); IC was pre 3.2 +/- 0.9 and post 2.6 +/- 0.7 L/m2 (p=0.001); CBV was pre 1.28 +/- 0.39 and post 1.09 +/- 0.32 L (p=0.001). TPR increased from 18.7 +/- 5.6 to 22.7 +/- 6.1 mmHg/L/min (p=0.001). Maximal CO reduction rate was found at 60 min, thereafter it reduced progressively. Log(CO1) increased in a non-linear way with body weight gain and similarly it decreased during UFR. A negative correlation was found between log(TPR1) and log(CO1-QA). CO reduction was associated with UFR and not with age, dialysis duration, left ventricular hypertrophy, sex and hemoglobin (Hb) in a multiple regression model (r2 =0.31, p=0.05). Qa/CO1 was 0.16 +/- 0.12. CBV/CO increased from 0.23 +/- 0.06 to 0.25 +/- 0.07%. CONCLUSIONS: Progressive CO reduction and TPR increase appear to be the typical hemodynamic features of bicarbonate HD with a UFR of moderate degree. Volume overload and CO increase were related in a non-linear way. TPR1 was strongly correlated with CO1-Qa, suggesting that a large arterovenous shunt was associated with increased resistance.

Adult↗