PRIAMUS--proximal flow blockage cerebral protectIon during carotid stenting: results from a multicenter Italian registry.

AIM: The aim of this Italian prospective registry was to evaluate the applicability and efficacy of the Mo.Ma Device (Invatec, Roncadelle, Italy) for the prevention of cerebral embolization during carotid artery stenting (CAS) in a real world population. METHODS: In 4 Italian centers, 416 patients (300 men; mean age 71.6+/-9 years) between October 2001 and March 2005 were enrolled in a prospective registry. Two-hundred and sixty-four symptomatic (63.46%) with >50% diameter stenosis and 152 (36.54%) asymptomatic patients with >70% diameter stenosis were included. The Mo.Ma Proximal Flow Blockage Embolic Protection System was used to perform protected CAS, achieving cerebral protection by endovascular clamping of the common carotid artery (CCA) and of the external carotid artery (ECA). RESULTS: Technical success, defined as the ability to establish protection with the Mo.Ma device and to deploy the stent, was achieved in 412 cases (99.03%). The mean duration of flow blockage was 4.91+/-1.1 min. Transient intolerances to flow blockage were observed in 24 patients (5.76%), but in all cases the procedure was successfully completed. No peri-procedural strokes and deaths were observed. Complications during hospitalization included 16 minor strokes (3.84%), 3 transient ischemic attacks (0.72%), 2 deaths (0.48%) and 1 major stroke (0.24%). This resulted in a cumulative rate at discharge of 4.56% all strokes and deaths, and of 0.72% major strokes and deaths. All the patients underwent thirty-day follow-up. At thirty-day follow-up, there were no deaths and no minor and major strokes, confirming the overall cumulative 4.56% incidence of all strokes and deaths rate, and of 0.72% rate of major strokes and deaths at follow up. In 245 cases (58.89%) there was macroscopic evidence of debris after filtration of the aspirated blood. CONCLUSIONS: This Italian multicenter registry confirms and further supports the efficacy and applicability of the endovascular clamping concept with proximal flow blockage in a broad patient series. Results match favorably with current available studies on carotid stenting with cerebral protection.

Aged↗

Effectiveness and safety of carotid endarterectomy under remifentanil.

AIM: The aim of this study was to evaluate the effectiveness and safety of carotid endarterectomy (CEA) with conscious sedation under remifentanil (Remifentanil anesthesia - RA) vs conventional loco-regional anesthesia (Conventional-LRA) in the current practice of a vascular surgery unit. METHODS: We introduced the ''Remifentanil-RA'' in our practice according to a two-step protocol. In the first step we performed a pilot prospective study to assess the procedure's safety and reproducibility in our setting on 60 consecutive patients with symptomatic and/or high-grade (>70%) internal carotid artery stenosis and alternately assigning them either to ''Remifentanil-RA'' or ''Conventional-LRA'' CEA. In the second step we analysed our routine operative records as to effectiveness and safety on 533 patients who consecutively underwent ''Remifentanil-RA'' CEA. We compared them with 533 age- and sex-matched historical controls who underwent ''Conventional-LRA'' CEA. RESULTS: The patients' mean age was 71.2+/-6.8 vs 71.8+/-6.1 (''Remifentanil-RA'' vs ''Conventional-LRA''). About 73% of them were male and 56% had a symptomatic carotid stenosis. Neither the pilot study nor second step comparison showed differences in outcome measures. We found only higher peri-operative nausea/ vomit (3.6% vs 0.4% ''Remifentanil-RA'' vs ''Conventional-LRA'', P<0.0002) and fewer re-operations for post-operative hematomas (3% vs 5.4% respectively, P=0.048). CONCLUSIONS: We found that ''Remifentanil-RA'' CEA was safe, effective and satisfactory. Nevertheless, with the potential problems of intubation and those already found with side effects, a randomized control trial (RCT) is needed in order to prove that this method is superior to ''Conventional-LRA'' CEA.

Aged↗

First clinical experiences with an endovascular clamping system for neuroprotection during carotid stenting.

OBJECTIVES: This report evaluates the feasibility and efficacy of an endovascular blood flow blockage technique to prevent intracerebral embolization of plaque debris during carotid artery stenting. METHODS: Forty-two patients were enrolled in five clinical sites in Germany and Italy with either an asymptomatic internal carotid artery stenosis > or =75% (mean 87%) or a symptomatic stenosis > or =60% (mean 85%). Cerebral protection during the stenting procedure was achieved using an endovascular clamping technique, obtained by occlusion of the external and common carotid artery via two independently inflatable balloons integrated in the Mo.Ma system. Blood with particulate plaque debris was aspirated before flow was restored. The patient's clinical and the neurological status were assessed during intervention, at discharge, and at 3 months follow-up. RESULTS: Stenting was performed in all but one patient. The mean flow occlusion time was 10.6+/-6.5 min. Transient clamping intolerance was observed in five patients (12%). In two patients, neurological deficits persisted for 2 and 12 h, respectively. Two minor strokes (4,7%) occurred at 5 and 72 h after the procedure. No major strokes or deaths were observed at 3 months follow-up. CONCLUSIONS: This first clinical experience with the Mo.Ma device substantiates the feasibility of endovascular clamping in preventing cerebral embolization during carotid artery stenting.

Carotid Artery, Internal↗

Alginate microparticles for Polymyxin B Peyer's patches uptake: microparticles for antibiotic oral administration.

Microparticles with size less than 3 microm, able to be taken up by M cell of Peyer's patches for the drug delivery to the Gut Associated Limphoid Tissue (GALT), were developed in order to improve oral bioavailability of Polymyxin B (PMB). Less than 3 microm alginate microparticles resistant to gastro-intestinal media were prepared by spray-drying technique and cross-linking by calcium ions and chitosan. The cross-linked microparticles were evaluated for PMB content by spectrophotometric method, alginate/PMB interaction by rheological study, cross-linking degree by EDS analysis and PMB activity by microbiological assay. By modulating the polymer cross-linking degree, cationic PMB interacted on alginate chains leading to a proper PMB loading as well as antibiotic retention in gastric environment and sustained delivery in intestinal fluid. Moreover, the procedure resulted suitable for PMB biological activity preservation.

Administration, Oral↗

Alginate microparticles for enzyme peroral administration.

In order to protect protein and peptide drugs against inactivation by different barriers in the gastro-intestinal tract and to improve their absorption, alginate microparticles as a carrier of L-lactate dehydrogenase, were developed by spray-drying technique. However, alginate complexation and spray-drying conditions led to enzyme activity loss. Such a drawback was overcome by using protectant additives (carboxymethylcellulose sodium salt, polyacrylic acid sodium salt, lactose) preventing the enzyme inactivation by both interaction with alginate and experimental conditions, lactose having the most protective effect. Nevertheless, only polyacrylic acid sodium salt provided a microparticulate structure required for the target of the Peyer's patches.

Alginates↗

Chitosan-alginate microparticles as a protein carrier.

The oral administration of peptidic drugs requires their protection from degradation in the gastric environment and the improvement of their absorption in the intestinal tract. For these requirements, a microsystem based on cross-linked alginate as the carrier of bovine serum albumin (BSA), used as a model protein, was proposed. A spray-drying technique was applied to BSA/sodium alginate solutions to obtain spherical particles having a mean diameter less than 10 microm. The microparticles were hardened using first a solution of calcium chloride and then a solution of chitosan (CS) to obtain stable microsystems. The cross-linking process was carried out at different CS concentrations and pH values of the cross-linking medium. The CS concentration affected the BSA loading in the microparticles prepared at a pH value less than the protein isoelectric point (pI). Moreover, the BSA loading at a pH value less than the pI was higher than that at a pH similar to the pI regardless of the CS concentration. This finding could be attributable to the formation of a BSA/alginate complex. The evaluation of the interaction between BSA and alginate at different pH values by means rheological measurements confirmed this hypothesis. This approach may represent a promising way to devise a microcarrier system with appropriate size for targeting the Peyer's patches, with appropriate immobilization capacity, and suitable for the oral administration of peptidic drugs.

Alginates↗

Eversion versus conventional carotid endarterectomy: late results of a prospective multicenter randomized trial.

OBJECTIVE: The durability of carotid endarterectomy (CEA) may be affected by carotid restenosis. The data from randomized trials show that the highest incidence of restenosis after CEA occurs from 12 to 18 months after surgery. The optimal CEA technique to reduce perioperative complications and restenosis rates is still undefined. This study examines the long-term clinical outcome and incidence of recurrent stenosis in patients who undergo eversion CEA. Previously published perioperative results of this study did not show statistically significant differences in study endpoints between the eversion and standard techniques. METHODS: From October 1994 to March 1997, 1353 patients with surgical indications for carotid stenosis were randomly assigned to undergo eversion (n = 678) or standard CEA (n = 675; primary closure, 419; patch, 256). Withdrawal from the assigned treatment occurred in 1.6% of the patients (in 13 assigned to eversion CEA, and in nine assigned to standard CEA). The clinical and duplex scan follow-up examination was 99% complete, and the mean follow-up interval was 33 months (range, 12 to 55 months). The primary outcomes were perioperative and late major stroke and death, carotid restenosis (stenosis >/= 50% of the lumen diameter detected at duplex scanning), and carotid occlusion. The primary evaluation of study outcomes was conducted on the basis of an intention-to-treat analysis. RESULTS: Restenosis was found at duplex scanning in 56 patients (19 in the eversion group, and 37 in the standard group). Within the standard group, the restenosis rates were 7.9% in the primary closure population and 1.5% in the patched population. Of the patients with restenosis, 36% underwent cerebral angiography that confirmed restenosis in all cases. The cumulative restenosis risk at 4 years was significantly lower in the group that underwent treatment with eversion CEA as compared with the standard group (3.6% vs 9.2%; P =.01), with an absolute risk reduction of 5. 6% and a relative risk reduction of 62%. Eighteen patients would have had to undergo treatment with eversion CEA to prevent one restenosis during the 4-year period. The incidence rate of ipsilateral stroke was 3.3% in the eversion population and 2.2% in the standard group. There were no significant differences in the cumulative risks of ipsilateral stroke (3.9% for eversion, and 2.2% for standard; P =.2) and death (13.1% for eversion, and 12.7% for standard; P =.7)) in the two groups. Of the 18 variables that were examined for their influence on restenosis, eversion CEA (hazard ratio, 0.3; 95% confidence interval, 0.2 to 0.6; P =.0004) and patch CEA (hazard ratio, 0.2; 95% confidence interval, 0.07 to 0.6; P =. 002) were negative independent predictors of restenosis with multivariate Cox proportional hazards regression analysis. CONCLUSION: The EVEREST (EVERsion carotid Endarterectomy versus Standard Trial) showed that eversion CEA is safe, effective, and durable. No statistically significant differences were found in late outcome between the eversion and standard techniques at the available follow-up examination.

Actuarial Analysis↗

PVP solid dispersions for the controlled release of furosemide from a floating multiple-unit system.

The poor bioavailability of orally dosed furosemide (FUR) is due to the presence of a biological window in the upper gastrointestinal tract. The purpose of the present study was to develop and optimize in vitro a multiple-unit floating system with increased gastric residence time for FUR. The incomplete release of FUR from the units, related to its low water solubility, led to the preparation and evaluation of different FUR samples to be incorporated into the units. The complete dose release over the actual intragastric residence time of the system (about 8 hr) was achieved by loading both the core and the membrane forming the units with a 1:5 FUR/polyvinylpyrrolidone (FUR/PVP) solid dispersion. Physicochemical analyses suggested the predominant role of the amorphous state of FUR in producing enhanced drug solubility and dissolution rate, which led to the desired release profile from the floating units.

Chemistry, Pharmaceutical↗

Mechanisms of myocardial ischemia in a patient with left main coronary artery atresia.

This report describes the different clinical and instrumental manifestations of coronary ischemia in a patient with left main coronary artery atresia. Exercise test and thallium-201 perfusion scintigraphy during isometric exercise test were negative for angina and electrocardiographic changes. Conversely, dipyridamole infusion caused severe angina, marked ST-segment changes and diffuse thallium-201 uptake abnormalities. This peculiar anatomical condition offers the opportunity of high-lighting the role played by the microcirculation in determining myocardial ischemia.

Adult↗

Endoluminal repair of infrarenal abdominal aortic aneurysms using a modular stent-graft: one-year clinical results from a European multicentre trial.

This is a report of a prospective study to evaluate the safety and efficacy of the Medtronic AneuRx stent-graft. Patients with an infrarenal aneurysm with a proximal neck length of greater than 10 mm and a neck diameter not greater than 26 mm and iliac artery diameters of at least 6 mm were accepted for endovascular repair using the Medtronic AneuRx modular stent-graft. A total of 104 patients were included in the study. Transfemoral placement of the bifurcated stent-graft was successful in 102 of 104 patients. Two conversions were performed. The mean operating time was 148 min (range 75-480) and the mean blood loss was 605 ml (range 100-2900). The mean follow-up was 15 months (range 12-21). Complications were rare and no kinking or migration occurred. At follow-up, four endoleaks persisted after 12 months. The Medtronic AneuRx stent-graft is a safe and efficacious alternative to open abdominal aortic aneurysm repair with excellent early results.

Aged↗

Effect of lesions of the nucleus basalis magnocellularis and of treatment with posatirelin on cholinergic neurotransmission enzymes in the rat cerebral cortex.

The effect of 4 and 8 weeks of treatment with the thyrotropin releasing hormone (TRH), analogue posatirelin (L-6-ketopiperidine-2-carbonyl-L-leucyl-proline amide), on the changes of cholinergic neurotransmission enzymes, choline acetyltransferase (ChAT) and acetylcholinesterase (AChE), caused by lesions of the nucleus basalis magnocellularis (NBM), was investigated in the rat frontal cortex. ChAT and AChE were demonstrated with immunohistochemical and histochemical techniques, respectively associated with image analysis and microdensitometry. Monolateral and bilateral lesions of NBM area caused a significant loss of ChAT-immunoreactive nerve cell bodies in the NBM, as well as a remarkable decrease of ChAT-immunoreactive fibres and of AChE reactivity in the frontal cortex ipsilateral to the lesion or of both sides, respectively. The number of ChAT-immunoreactive nerve cell bodies in the lesioned NBM was higher in posatirelin-treated rats for 8 weeks in comparison with control NBM-lesioned rats. Moreover, the compound increased the number of ChAT-immunoreactive fibres in the frontal cortex of monolaterally and bilaterally NBM-lesioned rats at 8 weeks after lesion, but was without effect on these fibres in sham-operated rats. The same is true for AChE reactivity, developed in the neuropil of the frontal cortex, which was restored in part by an 8-week treatment with posatirelin in NBM-lesioned rats. These findings suggest that treatment with posatirelin rescues cholinergic neurons of the NBM and cholinergic projections to the cerebral cortex affected by lesioning of the NBM. The functional relevance of these observations and their possible applications should be evaluated in future studies.

Acetylcholinesterase↗

A randomized study on eversion versus standard carotid endarterectomy: study design and preliminary results: the Everest Trial.

PURPOSE: The EVEREST Trial was designed to determine whether the surgical technique influences the durability and complications of carotid endarterectomy (CEA). The current report focuses on the study design and preliminary results. METHODS: EVEREST is a randomized multicenter trial. A total of 1353 patients with carotid stenosis requiring surgical treatment were randomly assigned to received standard (n = 675) or eversion (n = 678) CEA. Primary end points included carotid occlusion, major stroke, death, and restenosis rate. RESULTS: The rate of perioperative major stroke and death (1.3 for each study group) and the incidence of early carotid occlusion (0.6% for eversion vs 0.4% for standard) were similar. No significant differences were found between eversion and standard CEA with respect to incidence of perioperative transient ischemic accident, minor stroke, cranial nerve injuries, neck hematoma, myocardial infarction, or surgical defects as detected with intraoperative quality controls. Clamping time was significantly shorter for eversion CEA compared with patch standard procedures (31.7 +/- 15.9 vs 34.5 +/- 14.4 minutes, p = 0.02). A shunt was inserted in 11% of patients undergoing eversion CEAs and in 16% of patients undergoing standard procedures. Overall 30-day events occurred in 13.3% of the eversion group and in 11.4% of the standard group (p = 0.3). At a mean follow-up of 14.9 months (range, 1 to 38 months), 16 (2.4%) restenoses occurred in the eversion group and 28 (4.1%) occurred in the standard group (odds ratio, 0.56; 95% confidence interval, 0.3 to 1.1; p = 0.08). CONCLUSION: The preliminary results of the EVEREST Trial suggest that eversion CEA is a safe and rapid procedure with low major complication rates. No significant differences in restenosis rates were observed between eversion and standard CEA at the available follow-up. Longer-term results are necessary to assess whether the eversion technique influences the durability of CEA.

Adult↗

Experience with the Stentor endograft at four Italian centers.

PURPOSE: To report the outcome of an Italian multicenter trial of endovascular abdominal aortic aneurysm (AAA) exclusion using the Stentor device. METHODS: Between April 1995 and July 1996, 66 patients (63 men; average age 69 years, range 53 to 84) with infrarenal AAAs meeting the inclusion criteria were enrolled. The average diameter of the aneurysm was 4.6 cm (range 4.2 to 7). Three (4.5%) of the 66 AAAs were anastomotic aneurysms. RESULTS: Sixteen (25%) tubular and 50 (76%) bifurcated endograft procedures were attempted; 4 (6.1%) were converted and 1 terminated owing to technical faults with the bifurcated graft's second limb. One tube graft was too short and failed to exclude an anastomotic aneurysm. Sixty (91%) endograft procedures were completed successfully. Six (9.1%) vascular complications occurred, three in one patient who subsequently died of pulmonary embolism 72 hours postoperatively (1.5% mortality). There were four (6.1%) proximal endoleaks; two sealed spontaneously in < 1 month, and a third was converted (7.6% conversion rate). The fourth is being observed. Clinical success (aneurysm exclusion with no death or endoleak) at 30 days was 86.3% (57/66). In the 23-month follow-up of 57 eligible patients, 2 patients died of unrelated causes and 1 graft limb thrombosed, requiring a crossover femoral bypass. One patient was converted to surgical repair at 5 months postoperatively when increasing aneurysm size signaled an undisclosed endoleak (1.8% late conversion rate). Five other secondary endoleaks were treated with endovascular techniques. CONCLUSIONS: The Stentor was technically feasible in 10% to 40% of AAA candidates in this study, although deployment of the second limb was problematic in the bifurcated device. Introduction of the second-generation Vanguard endograft brought this study to an end.

Aged↗

Polysaccharide film-coating process for freely swellable hydrogels.

In order to control the drug release from coated hydrogels by preventing membrane fractures, an intramembrane freely swellable matrix device was designed by enclosing a void space between a crosslinked poly(vinyl alcohol) (PVA) matrix and a calcium alginate membrane. The highly swellable PVA matrix loaded with diltiazem hydrochloride was obtained by means of a simplified procedure of the polymer crosslinking reaction using glutaraldehyde in solution with ammonium persulfate. The undried swollen matrix was coated with a calcium alginate membrane employing an ionotropic gelation of sodium alginate induced by calcium ions. The subsequent drying process generated a void space separating the inner core from the membrane. The resulting calcium alginate membrane, which was uniform and compact in the structure, increased in thickness according to the coating time. Coating times exceeding 5 min allowed modification of the drug release profile providing, after a short burst period, sustained and constant rate phases in both simulated gastric fluid and simulated intestinal fluid. Because the inner hydrogel expanded freely inside the device, the unstressed and intact membrane could act as the rate-controlling factor in the drug release process. Owing to the pH-dependent behavior of the membrane, most of the drug was delivered in intestinal fluid. Therefore, the device proposed could be advantageously used for drug targeting to the small intestine.

Drug Delivery Systems↗

European multicentre experience with modular device (Medtronic Aneurx) for the endoluminal repair of infrarenal abdominal aortic aneurysms.

OBJECTIVE: Transfemoral endoluminal repair of AAA, introduced for the first time in the early 90's, has become a very promising alternative to conventional open repair and more and more centers are reporting satisfactory postoperative results in a high percentage of cases. Straight and bifurcated grafts represent the devices available on the market at present and aortic, as well as iliac aneurysmal lesions can be safely treated through a transfemoral approach. The possibility to indicate an endovascular AAA repair is related to the configuration (length and size) of the proximal and distal necks, tortuosity and calcification of the access arteries and to vascular and non-vascular comorbidities, which afflict the patients. The objective of our study was to evaluate the early and late postoperative results in a series of patients affected by infrarenal AAA, who underwent endoluminal repair. MATERIALS AND METHODS: From December 1996 to 31 October 1997 in 5 different European Centers, 100 Medtronic AneuRx bifurcated stent grafts were implanted for infrarenal abdominal aortic aneurysms. The diameter of the AAA varied from 33 to 77 mm (average 64 mm) and the mean age of the patients was 70.8 years (51-87 years). In one patient with a 33 mm diameter of the aneurysm, the surgical procedure was indicated because the size of the aneurysm had increased by 5 mm, compared to the previous control made 2 months before. In addition the aneurysm became symptomatic. There were 92 male and 8 female patients. The average time of the surgical procedure was 150 minutes (75-480 minutes) with an average blood loss of 570 ml (100-2,600 ml).

Aged↗

Evaluation of endovascular abdominal aortic aneurysm repair: anatomical classification, procedural success, clinical assessment, and data collection.

PURPOSE: To detail a methodology for evaluation of endovascular abdominal aortic aneurysm (AAA) repair that has been achieved through consensus of an international multidisciplinary team of investigators. METHODS: This schema features an anatomical classification for AAAs, a definition of procedural success, and a procedure for clinical assessment, as well as the necessary data collection forms. Patient data include demographics, procedural and clinical success, complications, and follow-up. Procedural details can be related to anatomic situations, comorbid processes, devices, and effective aneurysmal exclusion. RESULTS: These data would allow assessment of the procedures, physician learning curves, procedural indications, techniques, methodologies, the relationship of indications to success and complications, devices and subsequent graft patency, and aneurysmal exclusion. CONCLUSIONS: The use of this standardized data collection system could enable physicians and industry to better understand endovascular AAA repair and ultimately improve patient care.

Aortic Aneurysm, Abdominal↗

The Italian trial of endovascular AAA exclusion using the Parodi endograft.

PURPOSE: To report the outcome of the prospective 11-center Italian Parodi Trial using straight and tapered endografts for the endovascular exclusion of abdominal aortic aneurysms (AAA). METHODS: From April 1994 to July 1995, 27 patients were evaluated and selected for endovascular AAA exclusion. The Parodi devices were delivered through femoral arteriotomies using 18 to 22F introducers and deployed by balloon expansion of the terminal stents. RESULTS: Of 27 cases attempted, 24 endografts (15 tube, 9 aortomonoiliac) were implanted (1 deployment and 2 access failures [11.1%] were converted). Three endoleaks (12.5%) were treated intraoperatively with covered stents, two successfully, and the third sealed within 30 days. Three (12.5%) of the 24 treated patients died in-hospital of device-(n = 2) and procedure-related (n = 1) causes; the remaining 21 patients were discharged within 8 days. Of the 8 aortomonoiliac grafts in follow-up, only 1 (12.5%) failed in the mean 23-month (range 18 to 30) follow-up: however, 4 (31%) of 13 tube graft patients were converted to surgery within 18 months. Of the 16 (66.7%) surviving endografts at 2 years, 6 (38%) showed no change in the AAA diameter, while 10 (62%) had shrunk. CONCLUSIONS: The tube graft was applicable in only about 5% of cases, and accurate endograft sizing and distal fixation were problematic. The aortomonoiliac design was not appealing to surgeons but fared better in the long term. Given the advent of newer endograft models, the Italian Parodi Trial has been terminated.

Aged↗