PubMed HealthSearch

Biomedical subjects

G Corrigan

Publications and source records attributed to G Corrigan.

6 recordsLinked to original sources

Studies to evaluate the effectiveness of sex pheromone-impregnated formulations for control of populations of the American dog tick, Dermacentor variabilis (Say) (Acari: Ixodidae).

The sex pheromone, 2,6-dichlorophenol, was combined with a pesticide to control populations of the American dog tick, Dermacentor variabilis (Say). This pheromone persisted in the fur of treated dogs for at least 18 days. The mixture of pheromone and pesticide was much more effective in reducing mating among the surviving ticks than the treatments without pheromone. The pheromone-pesticide mixture also killed significantly more ticks than the treatment without pheromone. This increased effectiveness was due almost entirely to the significantly greater kill of male ticks. Combining the sex pheromone with pesticide treatments offers a means of suppressing tick populations by curtailing their mating and subsequent reproductive success. The potential applications of this technique and the benefits to be expected are discussed.

Animals

Eight-parameter automated hematology analyzers: comparison of two flow cytometric systems.

The performance of two high-speed 8-parameter automated hematology analyzers (Coulter Counter S-plus and ELT-8) were compared with that of reference instruments (Coulter Counter S Sr and Technicon Autocounter). The precision, linearity, and lack of carry-over of both instruments were superior over that of existing equipment. The especially noteworthy feature of the instruments was their excellent performance in the range of extreme values of both white blood cells and platelets. This enhanced performance, and the fact that all presently known relevant hematologic parameters can be measured by a single instrument on a single sample, make the contribution of these two flow cytometric-based instruments a significant advance in the field of automated laboratory medicine.

Autoanalysis

Standardization of platelet function tests.

Methods for the standardization of several currently used platelet function tests (bleeding time, capillary fragility, platelet retention, platelet aggregation, platelet factor 3, and platelet volume profiles) are presented, Different variables than may interfere with the reproducibility of the results of each assay were identified and standardized. Using the standardized techniques, the range of normal values for each test was determined in a large population of normal volunteers and used to identify disease states by comparing patient results with those of the normal population. A format for presenting the entire profile of platelet function parameters is proposed.

Adult

Modification of the total first metatarsophalangeal joint implant arthroplasty.

The Swanson Silastic HP 100 Flexible Hinge Toe Implant (Dow Corning Wright, Arlington Tennessee) displays superior tensile, elongation and tear propagation strength in comparison to other silicone implant materials. It is, however, subject to many factors which may shorten its life-span. One reason for such failure has been attributed to the irregular contour of bone ends created after metatarsophalangeal joint arthroplasty, resulting in abrasion shards and shearing fractures of the implant stems and hinge. Titanium grommets were developed to alleviate this factor. This case report demonstrates a complication subsequent to total first metatarsophalangeal joint implant arthroplasty and the effectiveness of the Swanson Flexible Hinge Toe Joint Grommet. (Dow Corning Wright, Arlington, Tennessee).

Consumer Behavior