PubMed Health⌕ Search

Biomedical subjects

G D Badhwar

Publications and source records attributed to G D Badhwar.

At least 55 records · Page 3Linked to original sources

Light ion components of the galactic cosmic rays: nuclear interactions and transport theory.

Light nuclei are present in the primary galactic cosmic rays (GCR) and are produced in thick targets due to projectile or target fragmentation from both nucleon and heavy ion induced reactions. In the primary GCR, 4He is the most abundant nucleus after 1H. However, there are also a substantial fluxes of 2H and 3He. In this paper we describe theoretical models based on quantum multiple scattering theory for the description of light ion nuclear interactions. The energy dependence of the light ion fragmentation cross section is considered with comparisons of inclusive yields and secondary momentum distributions to experiments described. We also analyze the importance of a fast component of lights ions from proton and neutron induced target fragmentation. These theoretical models have been incorporated into the cosmic ray transport code HZETRN and will be used to analyze the role of shielding materials in modulating the production and the energy spectrum of light ions.

Cosmic Radiation↗

Decay rate of the second radiation belt.

Variations in the Earth's trapped (Van Allen) belts produced by solar flare particle events are not well understood. Few observations of increases in particle populations have been reported. This is particularly true for effects in low Earth orbit, where manned spaceflights are conducted. This paper reports the existence of a second proton belt and it's subsequent decay as measured by a tissue-equivalent proportional counter and a particle spectrometer on five Space Shuttle flights covering an eighteen-month period. The creation of this second belt is attributed to the injection of particles from a solar particle event which occurred at 2246 UT, March 22, 1991. Comparisons with observations onboard the Russian Mir space station and other unmanned satellites are made. Shuttle measurements and data from other spacecraft are used to determine that the e-folding time of the peak of the second proton belt. It was ten months. Proton populations in the second belt returned to values of quiescent times within eighteen months. The increase in absorbed dose attributed to protons in the second belt was approximately 20%. Passive dosimeter measurements were in good agreement with this value.

Cosmic Radiation↗

Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models.

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

Brazil↗

In-flight radiation measurements on STS-60.

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

Atlantic Ocean↗

Effects of target fragmentation on evaluation of LET spectra from space radiations: implications for space radiation protection studies.

We present calculations of linear energy transfer (LET) spectra in low earth orbit from galactic cosmic rays and trapped protons using the HZETRN/BRYNTRN computer code. The emphasis of our calculations is on the analysis of the effects of secondary nuclei produced through target fragmentation in the spacecraft shield or detectors. Recent improvements in the HZETRN/BRYNTRN radiation transport computer code are described. Calculations show that at large values of LET (> 100 keV/micrometer) the LET spectra seen in free space and low earth orbit (LEO) are dominated by target fragments and not the primary nuclei. Although the evaluation of microdosimetric spectra is not considered here, calculations of LET spectra support that the large lineal energy (y) events are dominated by the target fragments. Finally, we discuss the situation for interplanetary exposures to galactic cosmic rays and show that current radiation transport codes predict that in the region of high LET values the LET spectra at significant shield depths (> 10 g/cm2 of Al) is greatly modified by target fragments. These results suggest that studies of track structure and biological response of space radiation should place emphasis on short tracks of medium charge fragments produced in the human body by high energy protons and neutrons.

Aluminum↗

Intercomparison of radiation measurements on STS-63.

A joint NASA Russia study of the radiation environment inside the Space Shuttle was performed on STS-63. This was the second flight under the Shuttle-Mir Science Program (Phase 1). The Shuttle was launched on 2 February 1995, in a 51.65 degrees inclination orbit and landed at Kennedy Space Center on 11 February 1995, for a total flight duration of 8.27 days. The Shuttle carried a complement of both passive and active detectors distributed throughout the Shuttle volume. The crew exposure varied from 1962 to 2790 microGy with an average of 2265.8 microGy or 273.98 microGy/day. Crew exposures varied by a factor of 1.4, which is higher than usual for STS mission. The flight altitude varied from 314 to 395 km and provided a unique opportunity to obtain dose variation with altitude. Measurements of the average east-west dose variation were made using two active solid state detectors. The dose rate in the Spacehab locker, measured using a tissue equivalent proportional counter (TEPC), was 413.3 microGy/day, consistent with measurements made using thermoluminescent detectors (TLDs) in the same locker. The average quality factor was 2.33, and although it was higher than model calculations, it was consistent with values derived from high temperature peaks in TLDs. The dose rate due to galactic cosmic radiation was 110.6 microGy/day and agreed with model calculations. The dose rate from trapped particles was 302.7 microGy/day, nearly a factor of 2 lower than the prediction of the AP8 model. The neutrons in the intermediate energy range of 1-20 MeV contributed 13 microGy/day and 156 microSv/day, respectively. Analysis of data from the charged particle spectrometer has not yet been completed.

Atlantic Ocean↗

Measurement of LET distribution and dose equivalent on board the space shuttle STS-65.

Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD)" utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 microSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5 degrees) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15-200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.

Atlantic Ocean↗

Measurements of the secondary particle energy spectra in the Space Shuttle.

Measurements of the energy spectra of secondary particles produced by galactic cosmic rays and trapped protons due to the nuclear interactions of these particles with the Shuttle shielding provide a powerful tool for validating radiation transport codes. A code validated in this way can be used to better estimate the dose and dose equivalent to body organs, measurements that cannot be made directly. The principal cause of single event upsets in electronic devices in the region of the South Atlantic Anomaly is secondary particles, and even in the region of galactic cosmic radiation a significant fraction is produced by secondary particles. In this paper, we describe the first direct measurements of the energy spectra of secondary protons, deuterons, tritons, 3He and 4He produced by galactic cosmic rays inside the Space Shuttle using a charged particle spectrometer. A comparison of these spectra with radiation transport code HZETRN showed reasonably good agreement for secondary protons. However, the code seriously underestimated the flux of all other light ions. The code has been modified to include pick-up and knock-on processes. The modified code leads to good agreement for deuterons and 3He but not for other light ions. This revised code leads to about 10% higher dose equivalent than the original code under moderate shielding, if we assume that higher charge ion fluxes are correctly predicted by the model.

Atlantic Ocean↗

A study of the radiation environment on board the Space Shuttle flight STS-57.

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on Space Shuttle flight STS-57 was conducted. The Shuttle flew in a nearly circular orbit of 28.5 degrees inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTDs) and thermoluminescent detectors (TLDs), and Russian nuclear emulsions, PNTDs and TLDs. All the detector systems were shielded by the same Shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micrometers and 200 keV/micrometers. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than the TLDs, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLDs to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Cosmic Radiation↗

Effects of target fragmentation on evaluation of LET spectra from space radiation in low-earth orbit (LEO) environment: impact on SEU predictions.

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

Aluminum↗

Measurements of trapped protons and cosmic rays from recent Shuttle flights.

We have flown two new charged particle detectors in five recent Shuttle flights. In this paper we report on the dose rate, equivalent dose rate, and radiation quality factor for trapped protons and cosmic radiation separately. A comparison of the integral linear energy transfer (LET) spectra with recent transport code calculations show significant disagreement. Using the calculated dose rate from the omni-directional AP8MAX model with IGRF reference magnetic field epoch 1970, and observed dose rate as a function of (averaged over all geographic latitude) and longitude, we have determined the westward drift of the South Atlantic anomaly. We have also studied the east-west effect, and observed a 'second' radiation belt. A comparison of the galactic cosmic radiation lineal energy transfer spectra with model calculations shows disagreement comparable to those of the trapped protons.

Atlantic Ocean↗

Long-term modulation of Galactic Cosmic Radiation and its model for space exploration.

As the human exploration of space has received new attention in the United States, studies find that exposure to space radiation could adversely impact the mission design. Galactic Cosmic Radiation (GCR), with its very wide range of charges and energies, is particularly important for a mission to Mars, because it imposes a stiff mass penalty for spacecraft shielding. Dose equivalent versus shielding thickness calculations, show a rapid initial drop in exposure with thickness, but an asymptotic behavior at a higher shielding thickness. Uncertainties in the radiobiology are largely unknown. For a fixed radiation risk, this leads to large uncertain ties in shielding thickness for small uncertainties in estimated dose. In this paper we investigate the application of steady-state, spherically-symmetric diffusion-convection theory of solar modulation to individual measurements of differential energy spectra from 1954 to 1989 in order to estimate the diffusion coefficient, kappa (r,t), as a function of time. We have correlated the diffusion coefficient to the Climax neutron monitor rates and show that, if the diffusion coefficient can be separated into independent functions of space and time: kappa (-r,t)=K(t)kappa 0 beta P kappa 1(r), where beta is the particle velocity and P the rigidity, then (i) The time dependent quantity 1/K(t), which is proportional to the deceleration potential, phi(r,t), is linearly related to the Climax neutron monitor counting rate. (ii) The coefficients obtained from hydrogen or helium intensity measurements are the same. (iii) There are different correlation functions for odd and even solar cycles. (iv) The correlation function for the Climax neutron monitor counting rate for given time, t, can be used to estimate mean deceleration parameter phi(t) to within +/- 15% with 90% confidence. We have shown that kappa(r,t) determined from hydrogen and/or helium data, can be used to fit the oxygen and iron differential energy spectra with a root mean square error of about +/- 10%, and essentially independent of the particle charge or energy. We have also examined the ion chamber and 14C measurements which allow the analysis to be extended from the year 1906 to 1990. Using this model we have defined reference GCR spectra at solar minimum and solar maximum. These can be used for space exploration studies and provide a quantitative estimate of the error in dose due to changes in GCR intensities.

Carbon Radioisotopes↗

Recent space shuttle observations of the South Atlantic Anomaly and the radiation belt models.

Active instruments consisting of a tissue equivalent proportional counter (TEPC) and a proton and heavy ion detector (PHIDE) have been carried on a number of Space Shuttle flights. These instruments have allowed us to map out parts of the South Atlantic Particle Anomaly (SAA) and to compare some of its features with predictions of the AP-8 energetic proton flux models. We have observed that consistent with the generally observed westward drift of the surface features of the terrestrial magnetic field the SAA has moved west by about 6.9 degrees longitude between the epoch year 1970 of the AP-8 solar maximum model and the Space Shuttle observations made twenty years later. However, calculations indicate that except for relatively brief periods following very large magnetic storms the SAA seems to occupy the same position in L-space as in 1970. After the great storm of 24 March 1991 reconfiguration of the inner radiation belt and/or proton injection into the inner belt, a second energetic proton belt was observed to form at L approximately = 2. As confirmed by a subsequent flight observations, this belt was shown to persist at least for six months. Our measurements also indicate an upward shift in the L location of the primary belt from L = 1.4 to L = 1.5. In addition we confirm through direct real time observations the existence and the approximate magnitude of the East-West effect.

Atlantic Ocean↗

Measurements of trapped protons and cosmic rays from recent Shuttle flights.

Two new charged particle detectors have been flown in five recent Shuttle flights. The tissue-equivalent proportional counter measures the lineal energy spectrum of space radiation in the 0.26-300 keV micrometer-1 range. The charged particle spectrometer is a double dE/dx x E and dE/dx x Chrenekov detector system which provides a measurement of the differential energy spectrum of protons from 13 to 350 MeV and dose rate in silicon. In this paper the dose rate, equivalent dose rate, and radiation, quality factor for trapped protons and cosmic radiation are reported on separately. A comparison of the integral LET spectra with recent transport code calculations shows significant disagreement. Using the calculated dose rate from the omnidirectional AP8MAX model with IGRF reference magnetic field epoch 1970, and observed dose rate as a function of geographic latitude and longitude, the westward drift of the south Atlantic anomaly has been determined. The east-west effect has also been studied and a 'second' radiation belt observed. A comparison of the galactic cosmic radiation (GCR) lineal energy transfer spectra with model calculations shows disagreement comparable with those of the trapped protons.

Atlantic Ocean↗

Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model.

A new class of tissue-equivalent proportional counters has been flown on two space shuttle flights. These detectors and their associated electronics cover a lineal energy range from 0.4 to 1250 keV/microns with a multichannel analyzer resolution of 0.1 keV/microns from 0.4 to 20 keV/microns and 5 keV/microns from 20 to 1250 keV/microns. These detectors provide the most complete dynamic range and highest resolution of any technique currently in use. On one mission, one detector was mounted in the Shuttle payload bay and another older model in the mid-deck, thus providing information on the depth dependence of the lineal energy spectrum. A detailed comparison of the observed lineal energy and calculated LET spectra for galactic cosmic radiation shows that, although the radiation transport models provide a rather accurate description of the dose (+/- 15%) and equivalent dose (+/- 15%), the calculations significantly underestimate the frequency of events below about 100 keV/microns. This difference cannot be explained by the inclusion of the contribution of splash protons. The contribution of the secondary pions, kaons and electrons produced in the Shuttle shielding, if included in the radiation transport model, may explain these differences. There are also significant differences between the model predictions and observations above 140 keV/microns, particularly for 28.5 degrees inclination orbit.

Aerospace Medicine↗

An analysis of interplanetary space radiation exposure for various solar cycles.

The radiation dose received by crew members in interplanetary space is influenced by the stage of the solar cycle. Using the recently developed models of the galactic cosmic radiation (GCR) environment and the energy-dependent radiation transport code, we have calculated the dose at 0 and 5 cm water depth; using a computerized anatomical man (CAM) model, we have calculated the skin, eye and blood-forming organ (BFO) doses as a function of aluminum shielding for various solar minima and maxima between 1954 and 1989. These results show that the equivalent dose is within about 15% of the mean for the various solar minima (maxima). The maximum variation between solar minimum and maximum equivalent dose is about a factor of three. We have extended these calculations for the 1976-1977 solar minimum to five practical shielding geometries: Apollo Command Module, the least and most heavily shielded locations in the U.S. space shuttle mid-deck, center of the proposed Space Station Freedom cluster and sleeping compartment of the Skylab. These calculations, using the quality factor of ICRP 60, show that the average CAM BFO equivalent dose is 0.46 Sv/year. Based on an approach that takes fragmentation into account, we estimate a calculation uncertainty of 15% if the uncertainty in the quality factor is neglected.

Cosmic Radiation↗

Depth-dose equivalent relationship for cosmic rays at various solar minima.

Galactic cosmic rays (GCR) pose a serious radiation hazard for long-duration missions. In designing a lunar habitat or a Mars transfer vehicle, the radiation exposure determines the shielding thickness, and hence the weight of spacecraft. In designing a habitat one has to focus on the worst-case radiation flux and its uncertainties. Using the spherically symmetric diffusion theory of the solar modulation of GCR, and data on the differential energy spectra of hydrogen, helium, oxygen, and iron from 1965 to 1989, it has been shown that the flux is determined by the diffusion parameter which is a function of the time in the solar cycle. This analysis also showed that the fluxes in the 1954 and 1976-1977 solar minima were similar and higher than those in 1965. In this paper, we have extended the spherical solar modulation theory back to 1954. These results show that the 1954-1955 GCR flux was nearly the same as that from 1976 to 1977 and that the 1965 flux values were nearly the same as those in 1986. Using this theory we have obtained the GCR spectra for all the nuclei and calculated the depth dose as a function of aluminum thickness. Using the ICRP 26 value for the quality factor, and the 1976-1977 spectra, it is shown that the shielding required to stay below 0.5 Sv is 17.5(-3)+8 g cm-2 of aluminum, and 9(-1.5)+5 g cm-2 to stay below 0.6 Sv. The calculated dose equivalent using the ICRP 60 values for quality factors is about 15% higher than that calculated using the ICRP 26 value. However, the errors on the quality factor itself may be substantial and are not taken into account.

Aluminum↗

Radiation issues for piloted Mars mission.

Man is now entering an era of colonizing the moon and exploration of Mars. The crewmembers of a piloted mission to Mars will be exposed to inner belt trapped protons, the outer trapped electrons, and the galactic cosmic radiation. In addition there is always the added risk of acute exposure to a solar particle event. Current radiation risk is estimated using the idea of absorbed dose and ICRP-26, LET-dependent quality factors. In a spacecraft with aluminum walls (2 g cm-2) at solar minimum the calculated dose equivalent is 0.73 Sv for a 406-day mission. Based on the current thinking this leads to an excess cancer mortality in a 35 year male of about 1%. About 75% of the dose equivalent is contributed by HZE particles and target fragments with average quality factors of 10.3 and 20, respectively. The entire concept of absorbed dose, quality factor, and dose equivalent as applied to such missions needs to be reexamined, in light of the fact that less than 50% of the nuclei in the body of the astronaut would have been traversed by a single GCR nuclei in the 406-day mission. Clearly, more biologically relevant information about the effects of heavy ions and target fragments is needed and fluence based risk estimation strategy developed for such long term stays in space.

Adult↗