Photogrammetric calibration of a stereo light microscope.

Quantitative stereo light microscopy has been used in very rare cases to obtain geometric representations of microscopic objects. Although the instrument itself has limitations, most of them efficiently overcome by other 3D microscopes, it bears considerable advantages in observing and measuring dynamic scenes with multiple objects. The biggest asset of the stereo method is that the full 3D work space is imaged in one shot - a property which distinguishes stereo from all the scanning techniques in 3D microscopy. With the work presented in this paper, we contribute to making the stereo technique applicable to the numerous mensuration tasks in the microscopic domain, where its potential would be invaluable.We report the photogrammetric calibration of a common main objective lens type stereo light microscope. Such a calibration is the initial step in ensuring accurate measurements with this instrument. First, we derive a mathematical formulation of the imaging function and discuss the estimation of the parameters involved. Then, three main problems of the practical implementation of the framework are addressed: the finding of a calibration standard, the automatic measuring of the many image coordinates required, and the stabilization of the parameter estimation. Finally, results of various calibration runs are presented and analysed under different aspects. Among these, the most important is the accuracy of the calibrated instrument in measuring 3D positions and positional relationships. With a Zeiss Stemi 11, Achromat 1.6 x we achieve accuracies of 1 per thousand laterally and 1-2% axially relative to the volume of the work space. On the highest magnification level this corresponds to 700 nm and 1.8 &mgr;m, respectively.

Journal Article↗

Pulsatile influxes of H+, K+ and Ca2+ lag growth pulses of Lilium longiflorum pollen tubes.

Fluxes of H+, K+ and Ca2+ were measured with self-referencing ion-selective probes, near the plasma membrane of growing Lilium longiflorum pollen tubes. Measurements from three regions around short, steady-growing tubes showed small, steady influx of H+ over the distal 40 microm and a region of the tube within 50-100 microm of the grain with larger magnitude efflux from the grain. K+ fluxes were immeasurable in short tubes. Measurements of longer tubes that were growing in a pulsatile manner revealed a pulsatile influx of both H+ and K+ at the growing tip. The average fluxes at the cell surface during the peaks of the H+ and K+ pulses were 489+/-81 and 688+/-144 pmol cm-2 second-1, respectively. Growth was measured by tracking the pollen tips with a computer vision system that achieved a spatial resolution of approximately 1/10 pixel. The high spatial resolution enabled the detection of growth, and thus the changes in growth rates, with a temporal sampling rate of 1 frame/second. These data show that the H+ and K+ pulses have a phase lag of 103+/-9 and 100+/-11 degrees, respectively, with respect to the growth pulses. Calcium fluxes were also measured in growing tubes. During steady growth, the calcium influx was relatively steady. When pulsatile growth began, the basal Ca2+ influx decreased and a pulsatile component appeared, superimposed on the reduced basal Ca2+ flux. The peaks of the Ca2+ pulses at the cell surface averaged 38.4+/-2.5 pmol cm-2 second-1. Longer tubes had large pulsatile Ca2+ fluxes with smaller baseline fluxes. The Ca2+ influx pulses had a phase lag of 123+/-9 degrees with respect to the growth pulses.

Calcium↗