PubMed Health⌕ Search

Biomedical subjects

G Derrien

Publications and source records attributed to G Derrien.

At least 19 recordsLinked to original sources

Potassium barium bismuth oxide.

KBa(4)Bi(3)O crystallizes in the centrosymmetric tetragonal space group I4/mcm. In this compound, bismuth is present as two anionic species, i.e. Bi(2)(4-) dumbbells [Bi-Bi 3.113 (3) A] and isolated Bi(3-). Atom Bi1 (Bi(3-)) lies inside a bicapped square antiprism (2 x K and 8 x Ba). Atom Bi2, which forms the Bi(2)(4-) dumbbell, sits inside a bicapped distorted trigonal prism (2 x K and 6 x Ba). O atoms occupy tetrahedral voids between Ba atoms.

Journal Article↗

Evaluation of detail reproduction for three die materials by using scanning electron microscopy and two-dimensional profilometry.

This study evaluated the reproduction of detail by Fuji-rock artificial stone, Epoxydent epoxy resin, and Steady-plast polyurethane resin. A polyvinyl siloxane impression was made of a disk-shaped calibration model, with etched grooves ranging from 1 to 46 microns in depth. The die materials were poured in the silicone impression of the disk, then examined with a scanning electron microscope and two-dimensional profilometer. The results revealed that the artificial stone could not reproduce details smaller than 20 microns because of the size of the crystalline structure, whereas epoxy resin and polyurethane resin accurately reproduced details of 1 to 2 microns.

Analysis of Variance↗

Comparison of transverse strength and dimensional variations between die stone, die epoxy resin, and die polyurethane resin.

This study compared transverse strength and dimensional variations of die stone, epoxy resin, and polyurethane resin. The polyurethane resin was tested unfilled, then filled with 20%, 40%, and 60% silica, by weight. Transverse strength was evaluated for five test strips for each material, and an original calibration plate technique closely simulating intraoral conditions was introduced to evaluate dimensional accuracy. Two series of five measurements for dimensional variations were recorded on each test strip. The first series was 15 minutes after removal from mold and the second series of 5 minutes a week later. The results were computed with a parametric ANOVA and Scheffe's test at 95% confidence level (p < or = 0.05). These results confirmed that die stone recorded the least dimensional change but was rigid and brittle, whereas epoxy resin and polyurethane resin had suitable mechanical properties including greater dimensional variations. Incorporating silica filler in polyurethane resins also reduced their transverse strength and sponsored minimal dimensional variations.

Analysis of Variance↗

[Provisional restorations in fixed prosthetics. Combination of photopolymerizing resin and composites].

This study shows the interest of using a light cured resin for temporary restorations. The rubber like stade enables easy removable of undercuts and excess material can be trimmed easily before light irradiation. Physico-chemical properties of light cured resin are compared with those of four chemical-polymerizing resins. Exothermic reaction, transverse strengths, modulus of elasticity, and differential scanning calorimetry show the same values as the best autopolymerizing resins. The author presents an original technic, using the light cured resin with light cured composites to achieve aesthetic and strong temporary restorations.

Composite Resins↗

Correlation of topography to bond strength of etched ceramic.

PURPOSE: Bonding techniques are commonly used today to ensure the durability of porcelain laminate veneers and ceramic inlay-onlays, which are esthetically pleasing solutions to the problem of dental restoration. Acid etching and silanization of porcelain have been widely used to enhance the retention between bonding resins and ceramic restorations. The purpose of this study was to evaluate the effect of surface modifications with 10% hydrofluoric acid gel and a coupling agent (a dual component silane) on the bond strength of 2 dental feldspathic ceramics (GC and PVS) bonded with an unfilled resin (Super-Bond). MATERIALS AND METHODS: Eighty samples of GC and eighty samples of PVS were built for a mechanical study. Mechanical tests were conducted using a Lloyd T 6000 R tensile machine, which determined the bond strengths of the 2 ceramics after different surface treatments (etching or silanization). In the next part of the study, 10 surfaces of GC and 10 surfaces of PVS were studied with a scanning mechanical microscope to evaluate the action of hydrofluoric acid gel on the roughness of the 2 ceramics. RESULTS: Etching ceramic with hydrofluoric acid gel increased the developed surface of feldspathic ceramics, especially for PVS, but this treatment was not sufficient to obtain the highest shear bond strength. The highly positive influence of silanization was shown, particularly for GC ceramic bonded with an unfilled resin. CONCLUSION: Silane combined with the action of hydrofluoric acid gel is the most effective surface treatment for ceramic.

Analysis of Variance↗