PubMed Health⌕ Search

Biomedical subjects

G Dollinger

Publications and source records attributed to G Dollinger.

15 recordsLinked to original sources

DNA-repair protein distribution along the tracks of energetic ions.

A simple model of homogenous chromatin distribution in HeLa-cell nuclei suggests that the track of an energetic ion hits 30 nm chromatin fibers with a mean distance of 0.55 mum. To test this assumption, living HeLa-cells were irradiated at the irradiation setup of the ion microprobe SNAKE using the ion beams provided by the Munich 14 MV tandem accelerator. After irradiation, the distribution of 53BP1 protein foci was studied by immunofluorescence. The observed 53BP1 distribution along the tracks of 29 MeV (7)Li ions and 24 MeV (12)C ions differed significantly from the expectations resulting from the simple chromatin model, suggesting that the biological track structure is determined by cell nuclear architecture with higher order organisation of chromatin.

Chromatin↗

Three-dimensional hydrogen microscopy in diamond.

A microprobe of protons with an energy of 17 million electron volts is used to quantitatively image three-dimensional hydrogen distributions at a lateral resolution better than 1 micrometer with high sensitivity. Hydrogen images of a <110>-textured undoped polycrystalline diamond film show that most of the hydrogen is located at grain boundaries. The average amount of hydrogen atoms along the grain boundaries is (8.1 +/- 1.5) x 10(14) per square centimeter, corresponding to about a third of a monolayer. The hydrogen content within the grain is below the experimental sensitivity of 1.4 x 10(16) atoms per cubic centimeter (0.08 atomic parts per million). The data prove a low hydrogen content within chemical vapor deposition-grown diamond and the importance of hydrogen at grain boundaries, for example, with respect to electronic properties of polycrystalline diamond.

Journal Article↗

Microirradiation of cells with energetic heavy ions.

The ion microprobe SNAKE at the Munich 14 MV tandem accelerator achieves beam focussing by a superconducting quadrupole doublet and can make use of a broad range of ions and ion energies, from 20 MeV protons to 200 MeV gold ions. Because of these properties, SNAKE is particularly attractive for biological microbeam experiments. Here we describe the adaptation of SNAKE for microirradiation of cell samples. This includes enlarging of the focal distance in order to adjust the focal plane to the specimen stage of a microscope, construction of a beam exit window in a flexible nozzle and of a suitable cell containment, as well as development of procedures for on-line focussing of the beam, preparation of single ions and scanning by electrostatic deflection of the beam. When irradiating with single 100 MeV (16)O ions, the adapted set-up permits an irradiation accuracy of 0.91 microm (full width at half maximum) in the x-direction and 1.60 microm in the y-direction, as demonstrated by retrospective track etching of polycarbonate foils. Accumulation of the repair protein Rad51, as detected by immunofluorescence, was used as a biological track detector after irradiation of HeLa cells with geometric patterns of counted ions. Observed patterns of fluorescence foci agreed reasonably well with irradiation patterns, indicating successful adaptation of SNAKE. In spite of single ion irradiation, we frequently observed split fluorescence foci which might be explained by small-scale chromatin movements.

Cells, Cultured↗

High throughput protein fold identification by using experimental constraints derived from intramolecular cross-links and mass spectrometry.

We have used intramolecular cross-linking, MS, and sequence threading to rapidly identify the fold of a model protein, bovine basic fibroblast growth factor (FGF)-2. Its tertiary structure was probed with a lysine-specific cross-linking agent, bis(sulfosuccinimidyl) suberate (BS(3)). Sites of cross-linking were determined by tryptic peptide mapping by using time-of-flight MS. Eighteen unique intramolecular lysine (Lys-Lys) cross-links were identified. The assignments for eight cross-linked peptides were confirmed by using post source decay MS. The interatomic distance constraints were all consistent with the tertiary structure of FGF-2. These relatively few constraints, in conjunction with threading, correctly identified FGF-2 as a member of the beta-trefoil fold family. To further demonstrate utility, we used the top-scoring homolog, IL-1beta, to build an FGF-2 homology model with a backbone error of 4.8 A (rms deviation). This method is fast, is general, uses small amounts of material, and is amenable to automation.

Animals↗

Classical light scattering quantitation of protein aggregates: off-line spectroscopy versus HPLC detection.

This paper describes the development and validation of a new off-line approach to quantitate both covalent and noncovalent, in-solution aggregates present in protein formulations and compares the new assay to established HPLC methods. This off-line analysis is well suited for use in QC release testing, formulation development and stability indicating applications. An inexpensive, continuous source HPLC fluorometer has been adapted with the addition of second order filters for use as a sensitive right-angle scatterometer which can determine the molecular weight of protein aggregates in solution. When used as an HPLC detector, right-angle light scattering is a sensitive method which can determine the molecular weight of peaks separable by HPLC, thus discriminating between monomers of different conformations and aggregates. The weight-averaged molecular weight of aggregate peaks can be calculated with system calibration, yielding the average number of monomers per aggregate. If the protein concentration is high enough for an adequate signal, the off-line technique of right-angle light scattering of protein formulations has advantages of convenience and speed over the HPLC approach. Samples are placed in standard fluorometer cuvettes and toluene is used as a calibrator. Data are presented which show the off-line (static) method to be extremely rapid, rugged and precise. The accuracy of this approach is demonstrated through cross-validation to traditional GPC analysis of protein aggregate distributions. This non-invasive light scattering approach is particularly useful when non-covalent protein aggregation is reversible and readily altered by chromatographic separations typically used for characterizing aggregates.

Calibration↗

Affinity selection and mass spectrometry-based strategies to identify lead compounds in combinatorial libraries.

The screening of diverse libraries of small molecules created by combinatorial synthetic methods is a recent development which has the potential to accelerate the identification of lead compounds in drug discovery. We have developed a direct and rapid method to identify lead compounds in libraries involving affinity selection and mass spectrometry. In our strategy, the receptor or target molecule of interest is used to isolate the active components from the library physically, followed by direct structural identification of the active compounds bound to the target molecule by mass spectrometry. In a drug design strategy, structurally diverse libraries can be used for the initial identification of lead compounds. Once lead compounds have been identified, libraries containing compounds chemically similar to the lead compound can be generated and used to optimize the binding characteristics. These strategies have also been adopted for more detailed studies of protein-ligand interactions.

Binding, Competitive↗

High resolution depth profile analysis by elastic recoil detection with heavy ions.

Elastic recoil detection (ERD) with energetic heavy ions (e.g. 60-120 MeV(127)I) is a suitable method to measure depth profiles of light and medium heavy elements in thin films. The advantages of this method are reliable and quantitative results and elementally and isotopically resolved depth profiles. A relative energy resolution of 0.07% has been measured in real ERD-experiments using the Q3D magnetic spectrograph at the Munich tandem accelerator and a large solid angle of detection of 5 msr. The good energy resolution allows atomic depth resolution near to the surface which has been obtained at flat and smooth carbon samples. A large solid angle of detection is necessary to measure a depth profile with the desired accuracy before the sample is significantly altered by the ion beam. As an example carbon profiles of thin carbon layers, prepared by a laser plasma ablation deposition process, have been investigated revealing the high depth resolution and its power to resolve elemental profiles at gradiated interfaces.

Journal Article↗

Kinetic PCR analysis: real-time monitoring of DNA amplification reactions.

We describe a simple, quantitative assay for any amplifiable DNA sequence that uses a video camera to monitor multiple polymerase chain reactions (PCRs) simultaneously over the course of thermocycling. The video camera detects the accumulation of double-stranded DNA (dsDNA) in each PCR using the increase in the fluorescence of ethidium bromide (EtBr) that results from its binding duplex DNA. The kinetics of fluorescence accumulation during thermocycling are directly related to the starting number of DNA copies. The fewer cycles necessary to produce a detectable fluorescence, the greater the number of target sequences. Results obtained with this approach indicate that a kinetic approach to PCR analysis can quantitate DNA sensitively, selectively and over a large dynamic range. This approach also provides a means of determining the effect of different reaction conditions on the efficacy of the amplification and so can provide insight into fundamental PCR processes.

DNA↗

Simultaneous amplification and detection of specific DNA sequences.

We have enhanced the polymerase chain reaction (PCR) such that specific DNA sequences can be detected without opening the reaction tube. This enhancement requires the addition of ethidium bromide (EtBr) to a PCR. Since the fluorescence of EtBr increases in the presence of double-stranded (ds) DNA an increase in fluorescence in such a PCR indicates a positive amplification, which can be easily monitored externally. In fact, amplification can be continuously monitored in order to follow its progress. The ability to simultaneously amplify specific DNA sequences and detect the product of the amplification both simplifies and improves PCR and may facilitate its automation and more widespread use in the clinic or in other situations requiring high sample throughput.

Alleles↗

Fourier transform infrared difference spectroscopy of bacteriorhodopsin and its photoproducts regenerated with deuterated tyrosine.

Fourier transform infrared (FTIR) difference spectroscopy has been used to detect the vibrational modes due to tyrosine residues in the protein that change in position or intensity between light-adapted bacteriorhodopsin (LA) and other species, namely, the K and M intermediates and dark-adapted bacteriorhodopsin (DA). To aid in the identification of the bands that change in these various species, the FTIR spectra of the free amino acids Tyr-d0, Tyr-d2 (2H at positions ortho to OH), and Tyr-d4 (2H at positions ortho and meta to OH) were measured in H2O and D2O at low and high pH. The characteristic frequencies of the Tyr species obtained in this manner were then used to identify the changes in protonation state of the tyrosine residues in the various bacteriorhodopsin species. The two diagnostically most useful bands were the approximately 1480-cm-1 band of Tyr(OH)-d2 and the approximately 1277-cm-1 band of Tyr(O-)-d0. Mainly by observing the appearance or disappearance of these bands in the difference spectra of pigments incorporating the tyrosine isotopes, it was possible to identify the following: in LA, one tyrosine and one tyrosinate; in the K intermediate, two tyrosines; in the M intermediate, one tyrosine and one tyrosinate; and in DA, two tyrosines. Since these residues were observed in the difference spectra K/LA, M/LA, and DA/LA, they represent the tyrosine or tyrosinate groups that most likely undergo changes in protonation state due to the conversions. These changes are most likely linked to the proton translocation process of bacteriorhodopsin.

Bacteriorhodopsins↗

Fourier-transform infrared difference spectroscopy of rhodopsin and its photoproducts at low temperature.

Fourier-transform infrared difference spectroscopy has been used to detect the vibrational modes in the chromophore and protein that change in position or intensity between rhodopsin and the photoproducts formed at low temperature (70 K), bathorhodopsin and isorhodopsin. A method has been developed to obtain infrared difference spectra between rhodopsin and bathorhodopsin, bathorhodopsin and isorhodopsin, and rhodopsin and isorhodopsin. To aid in the identification of the vibrational modes, we performed experiments on deuterated and hydrated films of native rod outer segments and rod outer segments regenerated with either retinal containing 13C at carbon 15 or 15-deuterioretinal. Our infrared measurements provide independent verification of the resonance Raman result that the retinal in bathorhodopsin is distorted all-trans. The positions of the C = N stretch in the deuterated pigment and the deuterated pigments regenerated with 11-cis-15-deuterioretinal or 11-cis-retinal containing 13C at carbon 15 are indicative that the Schiff-base linkage is protonated in rhodopsin, bathorhodopsin, and isorhodopsin. Furthermore, the C = N stretching frequency occurs at the same position in all three species. The data indicate that the protonated Schiff base has a C = N trans conformation in all three species. Finally, we present evidence that, even in these early stages of the rhodopsin photosequence, changes are occurring in the opsin and perhaps the associated lipids.

Animals↗

Trans/13-cis isomerization is essential for both the photocycle and proton pumping of bacteriorhodopsin.

We studied an analogue of bacteriorhodopsin whose chromophore is based on all-trans retinal. A five-membered ring was built around the 13-14 double bond so as to prohibit trans to 13-cis isomerization. No light-induced photochemical changes were seen, other than those due to a small amount (approximately 5%) of unbleached bacteriorhodopsin remaining in the apomembrane used for regeneration. The techniques used included flash photolysis at room and liquid nitrogen temperatures and Fourier-transform infrared difference spectroscopy. When the trans-fixed pigment was incorporated into phospholipid vesicles, no evidence of light-initiated proton pumping could be found. The results indicate that trans to 13-cis isomerization is essential for the photochemical transformation and function of bacteriorhodopsin.

Bacteriorhodopsins↗

Fourier transform infrared difference spectroscopy of bacteriorhodopsin and its photoproducts.

Fourier transform infrared difference spectroscopy has been used to obtain the vibrational modes in the chromophore and apoprotein that change in intensity or position between light-adapted bacteriorhodopsin and the K and M intermediates in its photocycle and between dark-adapted and light-adapted bacteriorhodopsin. Our infrared measurements provide independent verification of resonance Raman results that in light-adapted bacteriorhodopsin the protein-chromophore linkage is a protonated Schiff base and in the M state the Schiff base is unprotonated. Although we cannot unambiguously identify the Schiff base stretching frequency in the K state, the most likely interpretation of deuterium shifts of the chromophore hydrogen out-of-plane vibrations is that the Schiff base in K is protonated. The intensity of the hydrogen out-of-plane vibrations in the K state compared with the intensities of those in light-adapted and dark-adapted bacteriorhodopsin shows that the conformation of the chromophore in K is considerably distorted. In addition, we find evidence that the conformation of the protein changes during the photocycle.

Bacteriorhodopsins↗