PubMed Health⌕ Search

Biomedical subjects

G Drake

Publications and source records attributed to G Drake.

6 recordsLinked to original sources

Observation of muon neutrino disappearance with the MINOS detectors in the NuMI neutrino beam.

This Letter reports results from the MINOS experiment based on its initial exposure to neutrinos from the Fermilab NuMI beam. The rates and energy spectra of charged current nu(mu) interactions are compared in two detectors located along the beam axis at distances of 1 and 735 km. With 1.27 x 10(20) 120 GeV protons incident on the NuMI target, 215 events with energies below 30 GeV are observed at the Far Detector, compared to an expectation of 336+/-14 events. The data are consistent with nu(mu) disappearance via oscillations with |Delta(m)2/32|=2.74 +0.44/-0.26 x10(-3)eV(2) and sin(2)(2theta(23))>0.87 (68% C.L.).

Journal Article↗

Intra-abdominal pressure and rowing: the effects of inspiring versus expiring during the drive.

BACKGROUND: The lumbar vertebrae of rowers are subjected to high levels of shear and compression at mid-drive, but intra-abdominal pressure (IAP) may partially neutralize these forces. IAP fluctuates with breathing. This study compared the IAP between inspiring during the drive and expiring during the drive. METHODS EXPERIMENTAL DESIGN: ten volunteers performed one 5x2-minute repetition test while inspiring during the drive and one 5x2-minute repetition test while expiring during the drive on a rowing ergometer. The five work rates were: 100, 125, 150, 175 and 200 watts at 22, 24, 26, 28 and 30 strokes per minute, respectively. MEASURES: the movement of the body while rowing was analyzed using a position sensor, and IAP was measured using a pressure transducer catheter. RESULTS: A 2x5 repeated measures analysis of variance showed that there was a significant interaction for the dependent variable mid-drive IAP (p<0.05), with the mid-drive IAP increasing at a greater rate while expiring during the drive relative to inspiring during the drive. Across work rate, the mid-drive IAP and minimal IAP were significantly higher while expiring during the drive than inspiring during the drive (p<0.05). Across breathing pattern, the minimal IAP, maximal IAP, average change in IAP and mid-drive IAP increased significantly with work rate (p<0.05). CONCLUSIONS: The data show that expiring during the drive leads to a greater mid-drive IAP than inspiring during the drive.

Abdomen↗

Cystic renal lymphangiectasia: a distinctive clinicopathologic entity in the pediatric age group.

This report describes the features of unilateral cystic renal lymphangiectasia in a 2-year-old child who presented with hypertension, massive ascites, a left flank mass, and no evidence of familial renal cystic disease. The child became normotensive and is now asymptomatic more than 3 years after surgery. The clinical presentation and diffuse pathologic involvement are similar to findings for the few pediatric patients with cystic lymphangiectasia described in the literature and appear distinct from the more localized form of the disease seen in adults.

Child, Preschool↗