PubMed Health⌕ Search

Biomedical subjects

G Duffy

Publications and source records attributed to G Duffy.

At least 37 records · Page 2Linked to original sources

A membrane-immunofluorescent-viability staining technique for the detection of Salmonella spp. from fresh and processed meat samples.

A direct staining technique was investigated for the detection of viable Salmonella in fresh and processed meats. The technique involved overnight enrichment in BPW, extraction of Salmonella cells onto a polycarbonate membrane, followed by detection of the pathogen using anti-Salmonella monoclonal antibody coupled with an antibody linked-fluorescent stain (Texas Red) and a viability stain (Sytox Green). The technique was applied to the detection of Salm. enteritidis inoculated into broth culture or minced beef and then subjected to a variety of stresses including freezing (- 20 degrees C), heating (2 or 4 min at 56.9 degrees C), low pH (5 or 3.5) or high salt (2 or 4%). The correlation between traditional plate counts and the rapid count varied widely (r2 = 0.98-0.03), depending on the type and level of stress applied to the cells. The reason for the disparity in results obtained, and the potential application of the method as a diagnostic tool, are discussed.

Animals↗

Altering the NICU and measuring infants' responses.

UNLABELLED: The aim of the study was to measure the impact of a designated Quiet period on the NICU environment and its influence on the infants' physiological and movement responses. The study group comprised 10 preterm infants on assisted ventilation (mean gestational age 28.7 wk (range 24-32 wk), mean birthweight 1,322 g (range 600-2,060 g), mean age 5.2 d). The environment in which the infants were nursed was altered in terms of reduced light, noise, staff activity and infant handling. The infants' heart rate, blood pressure, oxygen saturation and movement responses were recorded during this Quiet period and compared with a period of Normal activity. When the Quiet period was compared with the Normal period (median values), the NICU environment had significantly altered in terms of Light: Quiet period 3.0 Lux, Normal period 254.5 Lux (p < 0.01); Noise: Quiet period 54.0 dB, Normal period 58.0 dB (p < 0.01); Alarm events: Quiet period 491.5 sec, Normal period 1,180.5 sec (p < 0.01); Staff conversation: Quiet period 16.0 occasions per hour, Normal period 60.0 occasions per hour (p < 0.01); Staff activity: Quiet period 25.5 occasions per hour, Normal period 59.0 occasions per hour (p <0.01); Infant handling: Quiet period 0.0 events per hour, Normal period 4.5 events per hour (p < 0.01). Infants' diastolic blood pressure and mean arterial pressure: median reduction of 2 mmHg for both during the Quiet period (p < 0.05). Infants' movements: Quiet period 14.5 movements per hour, Normal period 84.0 movements per hour (p < 0.05). DISCUSSION: This study demonstrates that Quiet periods are feasible for infants undergoing neonatal intensive care. The NICU environment was altered significantly for light, noise, infant handling and staff activity for a specified time period. These changes were associated with a reduced median diastolic blood pressure and mean arterial pressure and a decrease in infant movements.

Blood Pressure↗

Effect of pH on survival, thermotolerance, and verotoxin production of Escherichia coli O157:H7 during simulated fermentation and storage.

Heat treatment is increasingly being introduced to fermented meat processing, since the acid tolerance properties of Escherichia coli O157:H7 can permit this organism to survive traditional processing procedures. This study investigated the effect of growth pH and fermentation on the thermotolerance at 55 degrees C of E. coli O157:H7 in a model fermented meat system. E. coli O157:H7 (strain 380-94) was grown at pH 5.6 or 7.4 (18 h at 37 degrees C), fermented to pH 4.8 or 4.4 in brain heart infusion broth, and stored for 96 h. Cells grown at pH 5.6 had higher D values at 55 degrees C (D55 degrees C) than cells grown at pH 7.4 (P < 0.001). Cells fermented to pH 4.8 had higher D55 degrees C than those fermented to pH 4.4 (P < 0.001). Cells fermented to pH 4.8 demonstrated an increase in D55 degrees C during storage (P < 0.001), whereas cells fermented to pH 4.4 showed a decrease in D55 degrees C during the same period (P < 0.001). The effect of growth pH on verotoxin production by E. coli O157:H7 was assessed using the verotoxin assay. Cells grown at pH 5.6 had lower verotoxin production then cells grown at pH 7.4. This effect was not sustained over storage. These results indicate that a lower growth pH can confer cross-protection against heat. This has implications for the production of acidic foods, such as fermented meat, during which a heating step may be used to improve product safety.

Animals↗

The development of a combined surface adhesion and polymerase chain reaction technique in the rapid detection of Listeria monocytogenes in meat and poultry.

A procedure combining enrichment surface adhesion and polymerase chain detection (SA-PCR) was developed and applied in the detection of Listeria monocytogenes in meat products. Minced beef samples were inoculated with L. monocytogenes (log(10)3 cfu g(-1)) and incubated for 10 h at 30 degrees C in buffered peptone water. L. monocytogenes was recovered from the culture by attachment to a polycarbonate membrane immersed for 15 min in the enriched meat culture. The membrane and attached bacteria were removed from the culture and the membrane dissolved in phenol:chloroform. The DNA was extracted from the bacteria and a PCR assay was carried out using primers directed against the listerolysin O gene of L. monocytogenes. The combined (SA-PCR) technique had a detection limit of log10 4.0 cfu ml(-1) in enriched meat cultures. The rapid technique was applied to a small number of retail samples (n = 100) and was found to compare favourably to the standard cultural method. A total of 12 samples were confirmed positive for L. monocytogenes using the standard cultural method and the SA-PCR assay. No false positives or negatives were recorded by either method.

Animals↗

Isolation and detection of Listeria spp, Salmonella spp and Yersinia spp using a simultaneous enrichment step followed by a surface adhesion immunofluorescent technique.

The use of a rapid surface adhesion immunofluorescent (SAIF) technique for the isolation of three pathogens using a single enrichment step from broth and enriched meat cultures was investigated. Buffered peptone water (BPW, 225 ml) was inoculated with Listeria monocytogenes, Salmonella enteritidis and Yersinia enterocolitica to a level of 10 cfu ml(-1) and incubated overnight at 30 degrees C. Minced beef samples (25 g) were inoculated with the three pathogens to a level of 100 cfu g(-1) and incubated overnight at 30 degrees C in BPW (225 ml). Pathogens were isolated by surface adhesion to a polycarbonate membrane which was immersed in the enriched culture. The pathogens were detected using membrane counts (rinse and immunofluorescent) and standard plate counts. It was noted that the attachment of the three pathogens to the membrane was considerably enhanced when compared with single inoculum experiments and the reasons and implications of this for the rapid method are discussed. A small selection of naturally contaminated retail samples (n = 60) was tested for the presence of L. monocytogenes and S. enteritidis using a simultaneous enrichment step with SAIF detection and a standard cultural method of detection. A good correlation was found between both methods for L. monocytogenes (r2 = 0.91, RSD = 0.26) and S. enteritidis (r2 = 0.89, RSD = 0.28). This indicates that simultaneous analysis of these two pathogens could be carried out using the SAIF assay.

Animals↗

Total knee arthroplasty for steroid-induced osteonecrosis.

There have been only a few reports that evaluate the outcome of total knee arthroplasty in patients with steroid-induced osteonecrosis of the knee. We retrospectively reviewed 31 total knee arthroplasties in 24 patients with confirmed steroid-induced osteonecrosis of the knee. The average follow-up was 64 months. Of surviving knees, 92% had significant improvement in knee scores. Five knees (16%) required a revision procedure. Reasons for revision were aseptic loosening in 3 knees and sepsis in 2 knees. Complications not requiring revision occurred in 6 of 31 knees (19%). Survivorship of total knee arthroplasty to revision in patients with steroid-induced avascular necrosis of the knee was 84% at 5 years. Although there was a slightly higher complication rate, this may, in part, be due to the severity of the patients' underlying disease processes. Total knee arthroplasty can be a successful procedure for chronically ill patients with steroid-induced osteonecrosis.

Adult↗

Development of a surface adhesion immunofluorescent technique for the rapid detection of Salmonella spp. from meat and poultry.

A rapid method based on bacterial adhesion was developed for the detection of Salmonella in an enriched meat system. Minced beef samples inoculated with Salm. enteritidis (10 cfu g-1) were incubated overnight (18 h) at 37 degrees C in buffered peptone water. Salmonella enteritidis cells were isolated from the enriched meat sample by surface adhesion onto a polycarbonate membrane attached to a glass slide. The organisms attached to this polycarbonate membrane were subsequently visualized using immunofluorescent microscopy. The technique had a detection level of log10 3.5 Salmonella ml-1. The surface adhesion immunofluorescent technique correlated well with Salmonella plate counts (r2 = 0.99). Application of the rapid method to retail beef and poultry samples (n = 100) confirmed the correlation between this technique and traditional microbiological procedures. Thirty-one retail samples were reported positive for Salmonella species. No false positives or negatives were recorded for the rapid method.

Animals↗

The effect of pH and culture system on the attachment of plasmid-bearing and plasmid-cured Yersinia enterocolitica to a polycarbonate membrane in a surface adhesion immunofluorescent technique.

A rapid surface adhesion based immunofluorescence technique was used to isolate and detect Yersinia enterocolitica from inoculated enriched culture systems. The pathogen was isolated by surface adhesion to a polycarbonate membrane which was mounted on a glass slide and immersed in the enriched culture for 15 min. The pathogen was detected using a fluorescent labelled (FITC) monoclonal antibody which was specific for Y. enterocolitica serotype O:3 and then viewed using fluorescent microscopy. The effect of culture type (broth, meat homogenate and minced meat) and pH (5.00, 7.00, 9.00 and 11.00) on the adhesion of plasmid-bearing and plasmid-cured Y. enterocolitica to the polycarbonate membrane in this technique was determined. The pH had a significant effect (P < 0.05) in broth and meat homogenate cultures, with enhanced attachment of Y. enterocolitica (P+ and P-) at pH 9.00 than at pH 5, 7 or 11. Culture type was also important, with differences observed in the numbers of Yersinia adhering to membranes immersed in broth, meat homogenate and minced beef. Differences in attachment were noted between plasmid-bearing and plasmid-cured Y. enterocolitica isolated from similar cultural environments. The reasons for these observed differences, and their implications for the surface adhesion immunofluorescent rapid method, are discussed.

Bacterial Adhesion↗

Survival of Escherichia coli O157:H7 during the manufacture of pepperoni.

This study investigated the growth and survival of Escherichia coli O157:H7 during the manufacture of pepperoni to determine whether a 5-log10-unit decline in numbers, as recommended by the U.S. Food Safety and Inspection Service (FSIS), could be achieved. A range of pepperoni formulations with variations in salt (2.5 to 4.8%) and sodium nitrite (100 to 400 ppm) levels, and with pH (4.4 to 5.6) adjusted by manipulation of dextrose concentrations were prepared. The batters produced were inoculated with E. coli O157:H7 380-94 at a level of approximately 6.70 log10 CFU/g; changes in pathogen numbers, pH, titratable acidity, and sodium nitrite concentrations were monitored during fermentation and drying. With the standard commercial formulation (i.e., 2.5% salt, 100 ppm sodium nitrite, pH 4.8) E. coli O157:H7 numbers declined by approximately 0.41 log10 CFU/g during fermentation and a further 0.43 log10 CFU/g during subsequent drying (7 days). A regression equation was fitted to the data which showed significantly (P < 0.001) greater reductions in pathogen numbers in samples with increased salt and sodium nitrite contents and lowered pH. However declines were in all cases less than the target reduction of 5 log10 CFU/g.

Colony Count, Microbial↗

Cost analysis of autologous blood transfusion, using cell salvage, compared with allogeneic blood transfusion.

Autologous transfusion is an option infrequently used in the UK, partly because the direct costs are greater than for allogeneic transfusion. An analysis of the cost consequences of substituting autologous for allogeneic blood, by using cell salvage, was undertaken from a hospital perspective. Direct costs were estimated for two different cell salvage devices and sensitivity analysis performed on the key variables. Allogeneic transfusion may be associated with increased rates of postoperative infection due immunomodulation and immunosuppression. As a result, one of the short-term benefits of autologous transfusion is a possible reduction in length of hospital stay. This was the most important variable affecting the cost of autologous transfusion. Cost equivalence for autologous and allogeneic blood was reached at reductions in hospital stay of between 0.3 and 2 days across a range of variables. Reductions in length of hospital stay of this magnitude have been reported in several small studies. The results of our cost analysis suggest that autologous transfusion should not be rejected on the grounds of cost and we recommend a large-scale randomized controlled trial of autologous vs. allogeneic transfusion.

Blood Transfusion, Autologous↗

A comparison of immunomagnetic and surface adhesion immunofluorescent techniques for the rapid detection of Listeria monocytogenes and Listeria innocua in meat.

An immunomagnetic immunofluorescent method was investigated for the rapid detection of Listeria monocytogenes and Listeria innouca. This technique involved enrichment of the suspect sample at 30 degrees C overnight. Listeria monocytogenes cells were isolated from the enriched sample using immunomagnetic separation and Listeria were subsequently visualized using an immunofluorescent microscopy technique. This technique was used in the detection of Listeria cells from pure culture, inoculated beef mince samples and naturally contaminated retail beef mince samples. A detection level of approximately 1 x 10(3) cfu ml-1 was achieved. When compared with traditional detection methods no false negatives or positives were recorded for L. monocytogenes or L. innocua. The immunomagnetic immunofluorescent technique had a detection level similar to a previously described surface adhesion immunofluorescent technique. Isolation of the Listeria cells by surface adhesion involved dipping a membrane attached to a microscope slide into the enriched sample for 10 min. This was quicker and simpler to perform than the immunomagnetic separation technique which took 2 h to carry out.

Animals↗

A prospective randomized comparison between small bowel enteroclysis and small bowel follow-through in Crohn's disease.

BACKGROUND & AIMS: Small bowel enteroclysis (SBE) has been suggested to be superior to the small bowel follow-through (SBFT) for diagnosing the presence and extent of Crohn's disease. The aim was to perform a prospective randomized study at a single university medical center comparing SBE with SBFT in patients with Crohn's disease. METHODS: Consecutive patients with known Crohn's disease were randomized to receive either SBE or SBFT as the initial study and had the alternate study performed within 2 weeks. RESULTS: Twenty-six patients were enrolled. The mean time between studies was 8.7 +/- 0.8 days. Both studies were normal in 7 cases. The SBE was negative in 3 cases with positive findings of Crohn's disease by SBFT. One of these cases was a false-positive SBFT. The SBE and SBFT were both diagnostic of Crohn's disease in 15 cases; in 6 cases there was uniform agreement regarding disease pattern. The SBFT more accurately reported mucosal detail (n = 3) and a greater number of fistulas (n = 2). The SBE missed duodenal disease (n = 4). CONCLUSIONS: In known Crohn's disease, the SBFT is the procedure of choice. It is safer, preferred by patients, and will not miss gastroduodenal disease, and when the result is normal, there is no need to perform SBE.

Administration, Oral↗

The effect of temperature, pH and medium in a surface adhesion immunofluorescent technique for detection of Listeria monocytogenes.

A rapid surface adhesion-based immunofluorescence technique was used to detect Listeria monocytogenes from inoculated culture systems. The effect of culture type (pure, mixed and meat), pH (7.00, 6.40, 4.76 and 3.13), acids (citric and HCl) and temperature (25 degrees, 30 degrees and 37 degrees C) on the adhesion of Listeria to the polycarbonate membrane used in this technique was determined. It was found that pH had a significant effect (P < 0.05) with higher numbers of Listeria adhering at low pH values (4.76). Culture type was also important with significantly higher numbers of Listeria (P < 0.05) adhering to membranes immersed in meat cultures than in pure or mixed cultures. This effect was seen at 30 degrees C but not at 25 degrees or 37 degrees C. The total viable count (TVC) on the membrane was unaffected by pH but temperature had an influence with optimum adhesion occurring at 25 degrees C. The reasons for observed differences and their implications for the surface adhesion immunofluorescent rapid method are discussed.

Animals↗

Development of a surface adhesion immunofluorescent technique for the rapid isolation of Listeria monocytogenes and Listeria innocua from meat.

The use of a novel surface adhesion technique to isolate Listeria monocytogenes and Listeria innocua from an enrichment meat system was developed. Minced beef samples inoculated with L. monocytogenes (10 cfu g(-1)) were incubated at 30 degrees C for 14-18 h in a suitable enrichment broth. Listeria monocytogenes cells were isolated from the enriched meat sample by surface adhesion onto a polycarbonate membrane which was attached to a glass microscope slide. The Listeria cells on the membrane were subsequently visualized using an immunofluorescent microscopy procedure. The antibody used in this technique reacts with L. monocytogenes and L. innocua. The technique was demonstrated to have a detection level of log10 3.11 cfu ml(-1). There was excellent correlation (r2 = 0.98) between the counts obtained by this surface adhesion immunofluorescent (SAIF) technique and counts obtained using traditional methods, i.e. plate counts on PALCAM. When the regression equation relating the rapid and standard methods was validated using the data from 50 retail beef mince samples, an rsd value of +/- 0.25 was obtained. No false-negative or false-positive results were recorded for L. monocytogenes or L. innocua species using the SAIF technique.

Animals↗

Protecting the integrity of clinical laboratory test results.

The authors' inspection reports demonstrate that the improper alteration of patient data is not a rare aberration in private commercial clinical laboratories. Although laboratory surveyors could be trained to recognize this problem, the availability of unprotected test systems makes even trained inspectors ineffectual. Both regulatory agencies and professional accrediting agencies should be concerned that their surveyors may be placing a seal of approval on what are, in reality, compromised or even fabricated data. In proposing the regulations discussed in this paper, the FDA sought to "preserve the integrity of the agency's enforcement process." This goal will remain unattainable, however, until a mechanism has been devised to secure the original raw data produced by all of the analytical systems being used not only in clinical laboratories but also in environmental laboratories, pharmaceutical laboratories, etc. Laboratories, as well as regulatory agencies and accrediting bodies, need to be concerned on behalf of the patient, but laboratories may also need to be concerned on their own behalf. In the coming era of unprecedented cost constraints and competitive bidding, unscrupulous testing facilities or groups of such facilities could have a significant edge over their conscientious competitors if the issues raised here continue to be ignored. Although the analytical data management systems provide tremendous benefits, some have serious problems in ensuring the security of their data. However, if regulatory agencies, accrediting bodies, professional organizations, and the analyzer vendors make a united commitment, the problem of securing the integrity of analytical data could eventually be resolved. It is hoped that such a commitment will be made in the near future.

Autoanalysis↗