VIDAS D-dimer: fast quantitative ELISA for measuring D-dimer in plasma.

VIDAS D-dimer (bioMérieux) is a new quantitative ELISA for D-dimer determination designed for the VIDAS automated system. The test contains single-dose, ready-to-use reagents and is completed within 35 min. Quantitative results are obtained from a calibration curve stored in the software of the system and expressed as fibrinogen equivalent units. The two-step capture/tag test relies on two complementary monoclonal anti-D-dimer antibodies, the second one being labeled with alkaline phosphatase. The upper limit of the measuring range is 1000 micrograms/L and the lower detection limit is <50 micrograms/L, which is below the lower limit of the reference interval (68-494 micrograms/L). Reproducibility (CV) within and between runs ranges from 5% to 7%. There is no interference from heparin, bilirubin, hemoglobin, fibrinogen degradation products, or plasma turbidity. Comparison with a conventional ELISA (y) gave good correlation (r= 0.91, n= 579) and comparable results (y= 1.35x - 148, S(y/x)= 750), especially for D-dimer concentrations ranging from 0 to 1000 micrograms/L (y= 1.09x - 10.6, r= 0.88, S(y/x)= 170).

Alkaline Phosphatase↗

Evaluation of a new rapid quantitative D-dimer assay in patients with clinically suspected deep vein thrombosis.

The sensitivity and specificity for deep vein thrombosis (DVT) of a new rapid, quantitative and precise (total imprecision < 10%) D-dimer assay suitable for individual measurements (VIDAS D-DIMER, bio-Mérieux, France) were evaluated in a consecutive series of 103 in- and out-patients submitted to serial compression ultrasonography (C-US) for the clinical suspicion of DVT (n = 66) or of DVT recurrence (n = 37) and symptoms lasting from 1 to 15 days. DVT was found in 22 patients at baseline testing and no patient with an initially negative C-US developed vein incompressibility at follow up. The time elapsed from the onset of symptoms was negatively associated with D-dimer levels both in patients with and in those without DVT. In the entire series of patients, the sensitivity of a positive D-dimer test ( > or = 1.0 microgram/ml) for the presence of DVT was 96% (21/22 patients, 95% confidence interval 75-100%) with a specificity of 75% (64-84%), a negative predictive value of 98% (90-100%), a positive predictive value of 51% (35-67%), and an overall accuracy of 80% (70-87%). A normal D-dimer value (0.22 microgram/ml) was observed in one patient with DVT and symptoms lasting from 15 days. The approach of withholding C-US testing in patients with symptoms lasting from less than 11 days and D-dimer levels below the cut-off value was compared to serial C-US testing alone in a cost-effectiveness analysis subdividing the 66 patients with a first episode according to their clinical pretest probability of DVT. Thrombosis was detected in 6.7% of the patients in the low probability group (n = 15), 16.7% of the patients in the moderate probability group (n = 24), 51.9% of the patients in the high probability group (n = 27) and 8.1% of patients with suspected DVT recurrence. Calculated cost-savings for each DVT diagnosed ranged from 5% in the high pretest probability group to 55% in the low pretest probability group and to 77% in patients with suspected DVT recurrence. The safety of avoiding C-US testing in symptomatic patients with a negative D-dimer test should be evaluated in clinical management studies.

Adult↗

Contribution of a new, rapid, individual and quantitative automated D-dimer ELISA to exclude pulmonary embolism.

The performance of a new automated ELISA for a rapid, individual and quantitative measurement of plasma D-dimer (VIDAS D-dimer) has been evaluated. First, a study of 100 patients was performed in order to choose the best couple of antibodies in comparison with an already clinically validated ELISA. Then the results were certified in a prospective study including 195 consecutive patients suspected of pulmonary embolism (PE). For a cut-off level of 500 ng/ml VIDAS D-dimer showed a sensitivity of 100% (95% confidence interval 92-100), a specificity of 37.6%, a negative predictive value of 100% (95% CI 93.3-100) and a positive predictive value of 33.1%. During a 6 months' follow-up no patient (95% CI 0-6.4) with D-dimer < 500 ng/ml presented a new suspicion of venous thromboembolic disease. These results suggest that this rapid and single-dose ELISA provides a very useful tool for the clinician to exclude on a day-to-day basis the diagnosis of PE.

Autoanalysis↗

Enzymic urea assay: a new colorimetric method based on hydrogen peroxide measurement.

We describe a new enzymic colorimetric method in which urea is measured in serum by use of a single reagent mixture. Ammonia produced by urea hydrolysis, catalyzed by urease, reacts with glutamate and ATP in the presence of glutamine synthetase. The ADP so produced is assayed in reactions catalyzed sequentially by pyruvate kinase and pyruvate oxidase in a system that generates hydrogen peroxide. The hydrogen peroxide is measured at 500 or 550 nm in a reaction catalyzed by horseradish peroxidase, with phenol/4-aminophenazone as the chromogen. The reaction is complete in 15 min at 37 degrees C. The standard curve is linear up to a urea concentration of 40 mmol/L. Precision is good; CVs ranged from 2.5% to 3.1%. Results by the present method compared well with those by a candidate Reference Method and are not subject to interferences from commonly used drugs and anticoagulants.

Adenosine Diphosphate↗

Rapid determination of alpha-amylase activity by use of a new chromogenic substrate.

A new chromogenic substrate that is blocked at the nonreducing end, 4,6-benzylidene-alpha-D-4-nitrophenylmaltoheptaoside, is used to determine alpha-amylase (EC 3.2.1.1) activity in serum in a coupled assay with alpha-glucosidase (EC 3.2.1.20) and glucoamylase (EC 3.2.1.3) as auxiliary enzymes. The duration of the lag phase between 25 and 37 degrees C is less than 90 s, and the molar absorptivity of 4-nitrophenol is constant. The main cleavage product of the substrate by human pancreatic and salivary alpha-amylase is 4-nitrophenylmaltoside; in the presence of the auxiliary enzymes, greater than 95% of hydrolyzed substrate is accounted for as 4-nitrophenol. The combined reagent is stable for at least 20 days at 2-8 degrees C; precision is good, with CVs ranging from 1.7 to 3.3%; and the correlation of results with those by the 4-nitrophenylmaltoheptaoside method is excellent. Heparin (40 kilo-int. units/L), ascorbic acid (2.8 mmol/L), bilirubin (430 mumol/L), hemoglobin (170 mumol/L), glucose (55 mmol/L), and triglycerides (11 mmol/L) do not interfere in the assay.

Glucan 1,4-alpha-Glucosidase↗

[Study in man of the blood and urinary effects of intense muscular exercise on certain elements of protein metabolism].

The effect of heavy physical exercise of long and short duration was studied on a group of 33 sportsmen and non-sportsmen after a run on a treadmill. Blood samples were taken just before the exercise, just after, one hour later and the next day. Urine was collected during the 24 hours preceeding the exercise, just after, one hour after, and then until the following day. Urea, uric acid, creatinine were analysed in each sample and amount of excretion calculated. The results, show an obvious rise in protein catabolism. The increase in urea and uric acid is the consequence of increased adrenal functioning and the increase in creatinine can be explained as the consequence of an increase in its metabolism from phosphagen and creatine. A temporary impairment in renal function, resulting from hemodynamic and humoral conditions was also observed. The relative importance of these two mechanisms varies with the different subjects.