Rapid multivariate analysis and display of cross-reacting antibodies on human leukocytes.

We present an application which can rapidly determine the binding patterns of monoclonal antibodies on mixed populations of cells simultaneously in a single rapid analysis. It is an application of the tube identifier parameter (TIP) system which can provide fully correlated list-mode data of the entire patient phenotype in a single file. Using the phenogram analytical display, we are able to determine the cross-reacting antibodies for an entire antibody panel for each cell type. This information can be displayed in a single plot. Using light scatter gating to select different populations of lymphocytes, monocytes, and neutrophils, phenograms can be simultaneously generated. This provides a directly comparable means of displaying the positive and negative binding characteristics of each antibody on each cell population. Any marker combination that is abnormal will be identifiable in the phenogram. Additionally, by plotting the fluorescence distributions of each marker beside one another (termed overview), quantifiable differences in intensity can be determined. There are 3 major benefits of the proposed analysis. By using the TIP concept, several sets of antibodies can be compared simultaneously. Any light scatter gate can be used and this gate can be changed on one histogram or plot, yet apply to the total analysis. Data analysis is particularly rapid since the entire phenotype of a patient can be evaluated by performing a single rapid analysis.

Antibodies

Integration of a barcode reader with a commercial flow cytometer.

This report describes the application and installation of a barcode reader on a standard EPICS Elite flow cytometer. The barcode reader system eliminates keyboard entry of sample information on the cytometer. The system automates the transfer of sample information already present in our laboratory database to the cytometer at run time. The system uses a standard "off-the-shelf" bar code wand with a personal computer keyboard interface and requires no additional software at run time. No typing of sample information is required by the operator at any stage of normal sample operation at the cytometer. All operations are automatically coded into the cytometry software using the macro functions of the software. Tubes are inserted into the tube reader and sample information is transferred automatically into the cytometer. We have found that the system allows rapid and continuous operation of routine clinical and research samples. This automated data entry also reduces the possibility of data input errors.

Electronic Data Processing

An innovation in flow cytometry data collection and analysis producing a correlated multiple sample analysis in a single file.

The problems associated with rapid analysis and interpretation of data from multicolor immunofluorescence panels have been a formidable barrier to their routine use. Using present flow cytometry concepts, a panel of 11 tubes each containing multiple phenotypic markers or controls requires postdata acquisition manipulation of many multiparameter histogram and listmode files. We have developed a method that compresses all of the information from such a panel into a single listmode data file during run time. A single data file is used to record the entire phenotypic analysis for a particular patient or series within an experiment. This is accomplished by the incorporation of a tube identifier parameter (TIP) as well as the fluorescence and light scatter parameters normally collected. The TIP can then be used for gating discrimination of any tube or set of tubes within a panel. When the TIP is correlated with the PRISM parameter the entire patient phenotypic image can be represented within a single two-parameter histogram we have called a phenogram. This phenogram can be generated in real time, providing on-line preprocessing of a complex multicolor experiment. By examining the image created by the phenogram it is possible to rapidly flag abnormalities such as incorrect gating. This procedure was carried out on an EPICS Elite flow cytometer in its standard configuration with the addition of hardware to provide an input for the TIP.

Data Collection

Time interval gating for analysis of cell function using flow cytometry.

We propose a method which significantly shortens the time required for both the collection and analysis of data derived from multiple sample, flow cytometric kinetic assays. We have defined the term Time Interval Gating (TIG) to describe this method. TIG effectively allows one flow cytometer to concurrently monitor several samples over the course of a kinetic assay. Data for all samples are stored in a single FCS 2.0 compatible listmode data file which we refer to as the TIG data file. TIG is adaptable to most commerical flow cytometers. Standard listmode analysis software can be used to analyze the TIG data files and correlate any combination of tubes and/or time intervals from the assay. Results for the entire assay can be displayed on a single two parameter plot. This paper describes how TIG is applied to neutrophil oxidative burst measurement using a standard EPICS Elite flow cytometer. In this assay, 11 samples were each monitored for 30 min to identify the extent to which volatile organic chemicals (VOCs) inhibited the oxidation of DCFH in stimulated neutrophils. TIG makes the oxidative burst assay practical for high volume screening by reducing the overall flow cytometer and analysis time required by a factor of ten. In addition, TIG provides an organized approach to managing data acquisition on instruments equipped with automated sampling systems.

Flow Cytometry