PubMed Health⌕ Search

Biomedical subjects

G E Gold

Publications and source records attributed to G E Gold.

16 recordsLinked to original sources

Is cartilage thickness different in young subjects with and without patellofemoral pain?

OBJECTIVE: To determine the differences in load-bearing patellofemoral joint cartilage thickness between genders. To determine the differences in load-bearing cartilage thickness between pain-free controls and individuals with patellofemoral pain. METHODS: The articular cartilage thickness of the patella and anterior femur was estimated from magnetic resonance images in 16 young, pain-free control subjects (eight males, eight females) and 34 young individuals with patellofemoral pain (12 males, 22 females). The average age of all subjects was 28+/-4 years. The cartilage surfaces were divided into regions approximating the location of patellofemoral joint contact during knee flexion. The mean and peak cartilage thicknesses of each region were computed and compared using a repeated-measures Analysis of Variance. RESULTS: On average, males had 22% and 23% thicker cartilage than females in the patella (P < 0.01) and femur (P < 0.05), respectively. Male control subjects had 18% greater peak patellar cartilage thickness than males with patellofemoral pain (P < 0.05); however, we did not detect differences in patellar cartilage thickness between female control subjects and females with patellofemoral pain (P = 0.45). We detected no significant differences in femoral cartilage thickness between the control and pain groups. CONCLUSIONS: Thin cartilage at the patella may be one mechanism of patellofemoral pain in male subjects, but is unlikely to be a dominant factor in the development of pain in the female population.

Adult↗

MR imaging of articular cartilage at 1.5T and 3.0T: comparison of SPGR and SSFP sequences.

OBJECTIVE: To compare articular cartilage signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and thickness measurements on a 1.5 T and a 3.0 T magnetic resonance (MR) scanner using three-dimensional spoiled gradient recalled echo (3D-SPGR) and two 3D steady-state free precession (SSFP) sequences. METHODS: Both knees of five volunteers were scanned at 1.5 T and at 3.0 T using a transmit-receive quadrature extremity coil. Each examination consisted of a sagittal 3D-SPGR sequence, a sagittal fat suppressed 3D-SSFP (FS-SSFP) sequence, and a sagittal Dixon 3D-SSFP sequence. For quantitative analysis, we compared cartilage SNR and CNR efficiencies, as well as average cartilage thickness measurements. RESULTS: For 3D-SPGR, cartilage SNR efficiencies at 3.0 T increased compared to those at 1.5 T by a factor of 1.83 (range: 1.40-2.09). In comparison to 3D-SPGR, the SNR efficiency of FS-SSFP increased by a factor of 2.13 (range: 1.81-2.39) and for Dixon SSFP by a factor of 2.39 (range: 1.95-2.99). For 3D-SPGR, CNR efficiencies between cartilage and its surrounding tissue increased compared to those at 1.5 T by a factor of 2.12 (range: 1.75-2.47), for FS-SSFP by a factor 2.11 (range: 1.58-2.80) and for Dixon SSFP by a factor 2.39 (range 2.09-2.83). Average cartilage thicknesses of load bearing regions were not different at both field strengths or between sequences (P>0.05). Mean average cartilage thickness measured in all knees was 2.28 mm. CONCLUSION: Articular cartilage imaging of the knee on a 3.0 T MR scanner shows increased SNR and CNR efficiencies compared to a 1.5 T scanner, where SSFP-based techniques show the highest increase in SNR and CNR efficiency. There was no difference between average cartilage thickness measurements performed at the 1.5 T and 3.0 T scanners or between the three different sequences.

Adult↗

Considerations in measuring cartilage thickness using MRI: factors influencing reproducibility and accuracy.

OBJECTIVE: The primary goal of this study was to describe and evaluate conditions that could influence the precision and accuracy of measuring in vivo cartilage thickness in the weight bearing regions of the knee from magnetic resonance imaging (MRI). DESIGN: Three-dimensional (3D) models of the femoral cartilage were created from segmented MR images. The weight bearing regions on femoral cartilage were selected for the portion of the tibiofemoral joint that sustains contact during walking. Six regions of interest (three on each condyle) were located on the femur. Average cartilage thickness was calculated over each region. The sensitivity of the precision of the measurements to observer variability was evaluated using intra- and inter-observer reproducibility tests of cartilage thickness measurements from the MRI-derived 3D models. In addition, the quantitative influence of a rule-based protocol for segmentation was evaluated using the inter-observer reproducibility protocol. Accuracy tests were conducted on porcine knees by comparing 3D models from MR images and laser scans across weight bearing and non-weight bearing regions. RESULTS: The precision was substantially better for the intra-observer tests (Coefficient of variation (CV) = 1-3%) than the inter-observer tests. Adding a rule-based protocol reduced variability in inter-observer tests substantially (CV = 6.6% vs 8.3%). Accuracy tests showed that the central and weight bearing regions on each condyle were more accurate than boundary and non-weight bearing regions. In addition, these results indicate that care should be taken when determining cartilage thickness of weight bearing regions with cartilage degenerations, since the thickness of thinner cartilage can be systematically overestimated in MR images. CONCLUSIONS: A rule-based approach can substantially increase inter-observer reproducibility when measuring cartilage thickness from multiple observers. This improvement in inter-observer reproducibility could be an important consideration for longitudinal studies of disease progression. In quantifying cartilage thickness, central and weight bearing regions on each condyle can provide more accurate measurement than boundary and non-weight bearing regions with average accuracy of +/-0.2-0.3 mm. An important finding of this study was that the weight bearing regions, which are usually of the greatest clinical interest, were measured most accurately by sagittal plane imaging.

Cartilage, Articular↗

Dynamic MR imaging and stress testing in glenohumeral instability: comparison with normal shoulders and clinical/surgical findings.

Our objectives were to test the hypotheses that: 1) during shoulder motion, glenohumeral alignment differs between asymptomatic shoulders and those with symptomatic instability; 2) during magnetic resonance (MR)-monitored physical exam or stress testing, glenohumeral alignment differs between asymptomatic shoulders and those with instability; and 3) glenohumeral translation during MR stress testing correlates with findings of shoulder instability by clinical exam and exam under anesthesia (EUA). Using an open-configuration 0.5 T MR imaging (MRI) system, we studied symptomatic shoulders in 11 subjects and compared them to their contralateral asymptomatic shoulders. Each shoulder was studied during abduction/adduction and internal/external rotation to determine the humeral head position on the glenoid. An examiner also performed the MR stress test on each shoulder by applying manual force on the humeral head during imaging. All shoulders were assigned an instability grade from the MR stress test, and this grade was correlated with: 1) clinical exam grade assigned during preoperative assessment by an orthopedic surgeon and 2) intraoperative instability grade by EUA immediately preceding arthroscopy. With dynamic abduction and internal/external rotation, the humeral head remained centered on the glenoid in 9 of 11 shoulders, but in two subjects there were dramatic demonstrations of subluxation. With stress testing, a trend toward more joint laxity was demonstrated in symptomatic than in asymptomatic joints (P = 0.11). MR grading of instability correlated directly with clinical grading in six cases and underestimated the degree of instability relative to clinical exam in the other cases. MR instability grading systematically underestimated instability compared with EUA in 7 of the 10 cases that underwent surgical repair. We concluded that dynamic MR evaluation of glenohumeral alignment did not demonstrate abnormalities in symptomatic shoulders in 8 of 10 patients, whereas 2 patients showed dramatic findings of subluxation. Manual stress testing during dynamic MR examination showed a strong correlation with clinical instability grading. Dynamic shoulder MR examination during stress testing could, with further validation, become a useful adjunct to shoulder instability evaluations. J. Magn. Reson. Imaging 2001;13:748-756.

Adolescent↗

Future of MR imaging of articular cartilage.

Osteoarthritis, based on either cartilage injury or degeneration, is a leading cause of disability in the United States. Over the last several decades, much progress has been made in understanding cartilage injury and repair. Magnetic resonance (MR) imaging, with its unique ability to noninvasively image and characterize soft tissue, has shown promise in assessment of cartilage integrity. In addition to standard MR imaging methods, MR imaging contrast mechanisms under development may reveal detailed information regarding the physiology and morphology of cartilage. MR imaging will play a crucial role in assessing the success or failure of therapies addressing cartilage injury and degeneration.

Cartilage, Articular↗

Motion correction and lipid suppression for 1H magnetic resonance spectroscopy.

Spectral/spatial spin-echo pulses with asymmetric excitation profiles were incorporated into a PRESS-based localization sequence to provide lipid suppression while retaining a sufficient amount of water to allow for correction of motion-induced shot-to-shot phase variations. 1H magnetic resonance spectroscopy data were acquired at 1.5 Tesla from a motion phantom and in vivo from the human liver, kidney, and breast. The results demonstrated that lipids in the chemical shift stopband were completely suppressed and that full metabolite signal intensity was maintained after implementation of a regularization algorithm based on phasing the residual water signal. Liver and kidney spectra contained a large resonance at 3.2 ppm that was ascribed to trimethylammonium moieties (betaine plus choline) and a weaker signal at 3.7 ppm that may result from glycogen. A breast spectrum from a histologically proven invasive ductal carcinoma displayed a highly elevated choline signal (3.2 ppm) relative to that from a normal volunteer.

Adult↗

Plantar fasciitis and fascial rupture: MR imaging findings in 26 patients supplemented with anatomic data in cadavers.

Understanding of the normal anatomy of the plantar aponeurosis (PA) and familiarity with pathologic conditions are required for an accurate evaluation of the patient with subcalcaneal heel pain. In this study, we evaluated the diagnostic capabilities of magnetic resonance (MR) imaging in the assessment of the PA with close anatomic correlation. Herein, we describe the MR imaging features of plantar fasciitis and fascial rupture in 26 patients. High-spatial-resolution MR imaging was performed in four cadaveric feet, and a prescribed imaging plane was used for depiction of the peroneal component of the PA. MR imaging delineated the anatomy of the PA and perifascial soft tissues. The peroneal component was best visualized in prescribed sagittal oblique images. Perifascial edema was the most common finding of plantar fasciitis, and it was remarkable in those cases with acute fascial rupture. MR imaging reliably delineated the anatomy of the PA and may allow precise localization and definition of the extent of involvement in disease processes.

Adolescent↗

Ultra-short echo-time 2D time-of-flight MR angiography using a half-pulse excitation.

Flow-related artifacts remain a significant concern for magnetic resonance (MR) angiography because their appearance in angiograms adversely impacts accuracy in evaluation of arterial stenoses. In this paper, a half-pulse excitation scheme for improved two-dimensional time-of-flight (2D TOF) angiography is described. The proposed method eliminates the need for gradient moment nulling (of all orders), providing significant reductions in spin dephasing and consequent artifactual signal loss. Furthermore, because the post-excitation refocusing and flow compensation gradients are obviated, the achievable echo time is dramatically shortened. The half-pulse excitation is employed in conjunction with a fast radial-line acquisition, allowing ultra-short echo times on the order of 250-300 microsec. Radial-line acquisition methods also provide additional benefits for flow imaging: effective mitigation of pulsatile flow artifacts, full k-space coverage, and decreased scan times. The half-pulse excitation/radial-line sequence demonstrated improved performance in initial clinical evaluations of the carotid bifurcation when compared with a conventional 2D TOF sequence.

Action Potentials↗

MR imaging of articular cartilage using driven equilibrium.

The high incidence of osteoarthritis and the recent advent of several new surgical and non-surgical treatment approaches have motivated the development of quantitative techniques to assess cartilage loss. Although magnetic resonance (MR) imaging is the most accurate non-invasive diagnostic modality for evaluating articular cartilage, improvements in spatial resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) would be valuable. Cartilage presents an imaging challenge due to its short T(2) relaxation time and its low water content compared with surrounding materials. Current methods sacrifice cartilage signal brightness for contrast between cartilage and surrounding tissue such as bone, bone marrow, and joint fluid. A new technique for imaging articular cartilage uses driven equilibrium Fourier transform (DEFT), a method of enhancing signal strength without waiting for full T(1) recovery. Compared with other methods, DEFT imaging provides a good combination of bright cartilage and high contrast between cartilage and surrounding tissue. Both theoretical predictions and images show that DEFT is a valuable method for imaging articular cartilage when compared with spoiled gradient-recalled acquisition in the steady state (SPGR) or fast spin echo (FSE). The cartilage SNR for DEFT is as high as that of either FSE or SPGR, while the cartilage-synovial fluid CNR of DEFT is as much as four times greater than that of FSE or SPGR. Implemented as a three-dimensional sequence, DEFT can achieve coverage comparable to that of other sequences in a similar scan time. Magn Reson Med 42:695-703, 1999.

Cartilage, Articular↗

High-resolution three-dimensional in vivo imaging of atherosclerotic plaque.

The internal structure of atherosclerotic-plaque lesions may be a useful predictor of which lesions will rupture and cause sudden events such as heart attack or stroke. With lipid and flow suppression, we obtained high-resolution, three-dimensional (3D) images of atherosclerotic plaque in vivo that show the cap thickness and core size of the lesions. 3D GRASE was used because it provides flexible T(2) contrast and good resistance to off-resonance artifacts. While 2D RARE has similar properties, its resolution in the slice-select direction, which is important because of the irregular geometry of atherosclerotic lesions, is limited by achievable slice-excitation profiles. Also, 2D imaging generally achieves lower SNR than 3D imaging because, for SNR purposes, 3D image data is averaged over all the slices of a corresponding multislice 2D dataset. Although 3D RARE has many of the advantages of 3D GRASE, it requires a longer scan time because it uses more refocusing pulses to acquire the same amount of data. Finally, cardiac gating is an important part of our imaging sequence, but can make the imaging time quite long. To obtain reasonable scan times, a 2D excitation pulse was used to restrict the field of view. Magn Reson Med 42:762-771, 1999.

Aorta, Thoracic↗

Magnetic resonance imaging of knee cartilage repair.

Cartilage injury resulting in osteoarthritis is a frequent cause of disability in young people. Osteoarthritis, based on either cartilage injury or degeneration, is a leading cause of disability in the United States. Over the last several decades, much progress has been made in understanding cartilage injury and repair. Magnetic resonance (MR) imaging, with its unique ability to noninvasively image and characterize soft tissue, has shown promise in assessment of cartilage integrity. In addition to standard MR imaging methods, MR imaging contrast mechanisms under development may reveal detailed information regarding the physiology and morphology of cartilage. MR imaging will play a crucial role in assessing the success or failure of therapies for cartilage injury and degeneration.

Cartilage, Articular↗

Three-dimensional flow-independent peripheral angiography.

A magnetization-prepared sequence, T2-Prep-IR, exploits T1, T2, and chemical shift differences to suppress background tissues relative to arterial blood. The resulting flow-independent angiograms depict vessels with any orientation and flow velocity. No extrinsic contrast agent is required. Muscle is the dominant source of background signal in normal volunteers. However, long-T2 deep venous blood and nonvascular fluids such as edema also contribute background signal in some patients. Three sets of imaging parameters are described to address patient-specific contrast requirements. A rapid, spiral-based, three-dimensional readout is utilized to generate high-resolution angiograms of the lower extremities. Comparisons with x-ray angiography and two-dimensional time-of-flight angiography indicate that this flow-independent technique has unique capabilities to accurately depict stenoses and to visualize slow flow and in-plane vessels.

Angiography↗

MR spectroscopic imaging of collagen: tendons and knee menisci.

Water molecules associated with collagen have short transverse (T2) relaxation times. Projection-reconstruction techniques are able to achieve an echo time (TE) much shorter than conventional techniques, allowing imaging of tissues with T2 < 5 ms. Using these techniques, a conventional 1.5-T MRI human imaging system can directly image collagen-associated water from knee menisci and tendons in normal volunteers and patients. Long-T2 suppression improves the contrast between these structures and the surrounding tissue with long-T2 relaxation times. Spectroscopic imaging provides improved lipid/water registration and information about chemical composition and relaxation times. Direct imaging of tendons and menisci may provide more information about these structures and provide a new way to assess both injury and repair.

Collagen↗

Characterization of atherosclerosis with a 1.5-T imaging system.

It is shown that a conventional 1.5-T magnetic resonance (MR) imaging system can help characterize some of the key components of atherosclerotic plaque ex vivo. Fresh human aorta with atheromata was suspended in solutions of agarose and manganese chloride and heated to body temperature. The specimens were imaged with modified Dixon and projection-reconstruction imaging sequences. The specimens were then examined histologically to obtain direct correlation between images, spectra, and histologic characteristics. The results show that vessel wall and plaque components can be identified by means of their MR characteristics and correlated with their histologic appearance. The authors were able to identify normal vessel wall components, such as adventitial lipids and smooth muscle. They were also able to identify and localize plaque components such as fibrous tissue, calcification, lipids, and possible areas of hemorrhage and hemosiderin deposition.

Aged↗