Imaging nervous pathways with MR tractography.

This paper describes the state of the art of tractography, a technique which enables the virtual reconstruction of axon bundles of the central nervous system using diffusion-weighted magnetic resonance images. This technique has raised enthusiasm and expectations among specialists because it is the only non-invasive method for studying the three-dimensional architecture of axonal fibres in vivo. Tractography is a new technique used to assess the anatomy of the central nervous system, and it will be available for routine clinical use in the future. Understanding its potential applications and limitations is therefore important.

Algorithms↗

Evaluation of mixed effects in event-related fMRI studies: impact of first-level design and filtering.

With the introduction of event-related designs in fMRI, it has become crucial to optimize design efficiency and temporal filtering to detect activations at the 1st level with high sensitivity. We investigate the relevance of these issues for fMRI population studies, that is, 2nd-level analysis, for a set of event-related fMRI (er-fMRI) designs with different 1st-level efficiencies, adopting three distinct 1st-level filtering strategies as implemented in SPM99, SPM2, and FSL3.0. By theory, experiments, and simulations using physiological fMRI noise, we show that both design and filtering impact the outcome of the statistical analysis, not only at the 1st but also at the 2nd level. There are several reasons behind this finding. First, sensitivity is affected by both design and filtering, since the scan-to-scan variance, that is the fixed effect, is not negligible with respect to the between-subject variance, that is the random effect, in er-fMRI population studies. The impact of the fixed effects error on the sensitivity of the mixed effects analysis can be mitigated by an optimal choice of er-fMRI design and filtering. Moreover, the accuracy of the 1st- and 2nd-level parameter estimates also depend on design and filtering; especially, we show that inaccuracies caused by the presence of residual noise autocorrelations can be constrained by designs that have hemodynamic responses with a Gaussian distribution. In conclusion, designs with both good efficiency and decorrelating properties, for example, such as the geometric or Latin square probability distributions, combined with the "whitening" filters of SPM2 and FSL3.0, give the best result, both for 1st- and 2nd-level analysis of er-fMRI studies.

Adult↗

Intermolecular double quantum coherences (iDQc) and diffusion-weighted imaging (DWI) imaging of the human brain at 1.5 T.

To study the sensitivity of intermolecular double quantum coherences (iDQc) imaging contrast to brain microstructure and brain anisotropy, we investigated the iDQC contrast between differently structured areas of the brain according to the strength and the direction of the applied correlation gradient. Thus diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) maps have been obtained. This procedure, which consists of analyzing both iDQc and DWI images at different gradient strength and gradient direction, could be a promising tool for clinical brain investigations performed with higher than 1.5 T magnetic fields.

Anisotropy↗

Real-time quantification of T(2)(*) changes using multiecho planar imaging and numerical methods.

Conventional approaches to quantify whole brain T(2)(*) maps use nonlinear regression with intensive computational requirements that therefore likely limit quantitative T(2)(*) mapping for real-time applications. To overcome these limitations an alternative method, NumART(2)(*) (NUMerical Algorithm for Real-time T(2)(*) mapping) that directly calculates T(2)(*) by a linear combination of images obtained at three or more different echo times was developed. NumART(2)(*), linear least-squares, and nonlinear regression techniques were applied to multiecho planar images of the human brain and to simulated data. Although NumART(2)(*) may overestimate T(2)(*), it yields comparable values to regression techniques in cortical and subcortical areas, with only moderate deviations for echo spacings between 18 and 40 ms. NumART(2)(*), like linear regression, requires 2% of the computational time needed for nonlinear regression and compares favorably with linear regression due to its higher precision. The use of NumART(2)(*) for continuous on-line T(2)(*) mapping in real time fMRI studies is shown.

Adult↗

Improved detection of event-related functional MRI signals using probability functions.

Selecting an optimal event distribution for experimental use in event-related fMRI studies can require the generation of large numbers of event sequences with characteristics hard to control. The use of known probability distributions offers the possibility to control event timing and constrain the search space for finding optimal event sequences. We investigated different probability distributions in terms of response estimation (estimation efficiency), detectability (detection power, parameter estimation efficiency, sensitivity to true positives), and false-positive activation. Numerous simulated event sequences were generated selecting interevent intervals (IEI) from the uniform, uniform permuted, Latin square, exponential, binomial, Poisson, chi(2), geometric, and bimodal probability distributions and fixed IEI. Event sequences from the bimodal distribution, like block designs, had the best performance for detection and the poorest for estimation, while high estimation and detectability occurred for the long-decay exponential distribution. The uniform distribution also yielded high estimation efficiency, but probability functions with a long tail toward higher IEI, such as the geometric and the chi(2) distributions, had superior detectability. The distributions with the best detection performance also had a relatively high incidence of false positives, in contrast to the ordered distributions (Latin square and uniform permuted). The predictions of improved sensitivities for distributions with long tails were confirmed with empirical data. Moreover, the Latin square design yielded detection of activated voxels similar to the chi(2) distribution. These results indicate that high detection and suitable behavioral designs have compatibility for application of functional MRI methods to experiments requiring complex designs.

Adult↗

Turbo-Proton Echo Planar Spectroscopic Imaging (t-PEPSI) MR technique in the detection of diffuse axonal damage in brain injury. Comparison with Gradient-Recalled Echo (GRE) sequence.

PURPOSE: Diffuse axonal injury (DAI) is a common type of primary neuronal injury in patients with severe traumatic brain injury, and is frequently accompanied by tissue tear haemorrhage. The T2*-weighted gradient-recalled echo (GRE) sequences are more sensitive than T2-weighted spin-echo images for detection of haemorrhage. This study was undertaken to determine whether turbo-PEPSI, an extremely fast multi-echo-planar-imaging sequence, can be used as an alternative to the GRE sequence for detection of DAI. MATERIALS AND METHODS: Nineteen patients (mean age 24,5 year) with severe traumatic brain injury (TBI), occurred at least 3 months earlier, underwent a brain MRI study on a 1.5-Tesla scanner. A qualitative evaluation of the turbo-PEPSI sequences was performed by identifying the optimal echo time and in-plane resolution. The number and size of DAI lesions, as well as the signal intensity contrast ratio (SI CR), were computed for each set of GRE and turbo-PEPSI images, and divided according to their anatomic location into lobar and/or deep brain. RESULTS: There was no significant difference between GRE and turbo-PEPSI sequences in the total number of DAI lesions detected (283 vs 225 lesions, respectively). The GRE sequence identified a greater number of hypointense lesions in the temporal lobe compared to the t-PEPSI sequence (72 vs 35, p<0.003), while no significant differences were found for the other brain regions. The SI CR was significantly better (i.e. lower) for the turbo-PEPSI than for the GRE sequence (p<0.00001). CONCLUSIONS: Owing to its very short scan time and high sensitivity to the haemorrhage foci, the turbo-PEPSI sequence can be used as an alternative to the GRE to assess brain DAI in severe TBI patients, especially if uncooperative and medically unstable.

Journal Article↗