PubMed Health⌕ Search

Biomedical subjects

G El Fakhri

Publications and source records attributed to G El Fakhri.

5 recordsLinked to original sources

Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT.

UNLABELLED: Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images are affected by scatter, cross talk, attenuation, distance-dependent collimator response (DCR), and partial-volume effect. We determined the accuracy and precision of activity quantitation in simulated normal and pathologic studies of simultaneous 123I/99mTc brain SPECT when compensating for all degrading phenomena. METHODS: Monte Carlo simulations were performed using the Zubal brain phantom. Contamination caused by high-energy 123I decay photons was incorporated. Twenty-four 99mTc and 123I activity distributions were simulated on the basis of normal and pathologic patient activity distributions. Cross talk and scatter were corrected using a new method based on a multilayer perceptron artificial neural network (ANN), as well as by the asymmetric window (AW) approach; for comparison, unscattered (U) photons of 99mTc and 123I were recorded. Nonuniform attenuation and DCR were modeled in an iterative ordered-subset expectation maximization (OSEM) algorithm. Mean percentage biases and SDs over the 12 normal and 12 pathologic simulated studies were computed for each structure with respect to the known activity distributions. RESULTS: For 123I, AW + OSEM yielded a bias of 7% in the cerebellum, 21% in the frontal cortex, and 36% in the corpus callosum in the simulated normal population. The bias was increased significantly in the striata of simulated pathologic studies (P < 0.05). The bias associated with ANN was significantly lower (<9% in these brain structures, P < 0.05). For 99mTc with AW + OSEM, the bias was 60% in the corpus callosum, 36% in the striata, and 18%-22% in the cortical lobes in the simulated normal population. This bias was <11% in all brain structures with ANN. In the simulated pathologic population, the bias associated with AW increased significantly in the cortical lobes to 55% (P < 0.05), although it did not change significantly with ANN. CONCLUSION: The accuracy and variability over simulated normal and pathologic studies of both 99mTc and 123I activity estimates were very close with ANN to those obtained with U + OSEM. ANN + OSEM is a promising approach for absolute activity quantitation in simultaneous 99mTc/123I SPECT.

Alzheimer Disease↗

Should scatter be corrected in both transmission and emission data for accurate quantitation in cardiac SPET?

Ideally, reliable quantitation in single-photon emission tomography (SPET) requires both emission and transmission data to be scatter free. Although scatter in emission data has been extensively studied, it is not well known how scatter in transmission data affects relative and absolute quantitation in reconstructed images. We studied SPET quantitative accuracy for different amounts of scatter in emission and transmission data using a Utah phantom and a cardiac Data Spectrum phantom including different attenuating media. Acquisitions over 180 degrees were considered and three projection sets were derived: 20% images and Jaszczak and triple-energy-window scatter-corrected projections. Transmission data were acquired using gadolinium-153 line sources in a 90-110 keV window using a narrow or wide scanning window. The transmission scans were performed either simultaneously with the emission acquisition or 24 h later. Transmission maps were reconstructed using filtered backprojection and mu values were linearly scaled from 100 to 140 keV. Attenuation-corrected images were reconstructed using a conjugate gradient minimal residual algorithm. The mu value underestimation varied between 4% with a narrow transmission window in soft tissue and 22% with a wide window in a material simulating bone. Scatter in the emission and transmission data had little effect on the uniformity of activity distribution in the left ventricle wall and in a uniformly hot compartment of the Utah phantom. Correcting the transmission data for scatter had no impact on contrast between a hot and a cold region or on signal-to-noise ratio (SNR) in regions with uniform activity distribution, while correcting the emission data for scatter improved contrast and reduced SNR. For absolute quantitation, the most accurate results (bias <4% in both phantoms) were obtained when reducing scatter in both emission and transmission data. In conclusion, trying to obtain the same amount of scatter in emission and transmission data, in addition to being impractical because of the difficulty in knowing the precise scatter components, did not yield such accurate absolute activity quantitation as when emission and transmission scatter were reduced.

Heart↗

Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT.

UNLABELLED: We determined the relative effect of corrections for scatter, depth-dependent collimator response, attenuation, and finite spatial resolution on various image characteristics in cardiac SPECT. METHODS: Monte Carlo simulations and real acquisition of a 99mTc cardiac phantom were performed under comparable conditions. Simulated and acquired data were reconstructed using several correction schemes that combined different methods for scatter correction (3 methods), depth-dependent collimator response correction (frequency-distance principle), attenuation correction (nonuniform Chang correction or within an iterative reconstruction algorithm), and finite spatial resolution correction (use of recovery coefficients). Five criteia were considered to assess the effect of the processing schemes: bull's-eye map (BEM) uniformity, contrast between the left ventricle (LV) wall and the LV cavity, spatial resolution, signal-to-noise ratio (SNR), and percent errors with respect to the known LV wall and liver activities. RESULTS: Similar results were obtained for the simulated and acquired data. Scatter correction significantly improved contrast and absolute quantitation but did not have noticeable effects on BEM uniformity or on spatial resolution and reduced the SNR. Correction for the depth-dependent collimator response improved spatial resolution from 13.3 to 9.5 mm in the LV region, improved absolute quantitation and contrast, but reduced the SNR. Correcting for attenuation was essential for restoring BEM uniformity (78% and 89% without and with attenuation correction, respectively [ideal value being 100%]) and accurate absolute activity quantitation (errors in estimated LV wall and liver activity decreased from 90% without attenuation correction to approximately20% with attenuation correction only). Although accurate absolute activity quantitation was achieved in the liver using scatter and attenuation corrections only, correction for finite spatial resolution was needed to estimate LV wall activity within 10%. CONCLUSION: The respective effects of corrections for scatter, depth-dependent collimator response, attenuation, and finite spatial resolution on different image features in cardiac SPECT were quantified for a specific acquisition configuration. These results give indications regarding the improvements to be expected when using a specific processing scheme involving some or all corrections.

Heart↗

A spline-regularized minimal residual algorithm for iterative attenuation correction in SPECT.

In SPECT, regularization is necessary to avoid divergence of the iterative algorithms used for non uniform attenuation compensation. In this paper, we propose a spline-based regularization method for the minimal residual algorithm. First, the acquisition noise is filtered using a statistical model involving spline smoothing so that the filtered projections belong to a Sobolev space with specific continuity and derivability properties. Then, during the iterative reconstruction procedure, the continuity of the inverse Radon transform between Sobolev spaces is used to design a spline-regularized filtered backprojection method, by which the known regularity properties of the projections determine those of the corresponding reconstructed slices. This ensures that the activity distributions estimated at each iteration present regularity properties, which avoids computational noise amplification, thus stabilizing the iterative process. Analytical and Monte Carlo simulations are used to show that the proposed spline-regularized minimal residual algorithm converges to a satisfactory stable solution in terms of restored activity and homogeneity, using at most 25 iterations, whereas the non regularized version of the algorithm diverges. Choosing the number of iterations is therefore no longer a critical issue for this reconstruction procedure.

Algorithms↗

Artificial neural network as a tool to compensate for scatter and attenuation in radionuclide imaging.

UNLABELLED: This study investigates the ability of artificial neural networks (ANN) to simultaneously correct for attenuation and Compton scattering in scintigraphic imaging. METHODS: Three sets of experiments are conducted using images of radioactive sources with various shapes and distributions in a homogeneous medium. Numerical Monte Carlo simulations and physical phantom acquisitions of radioactive geometric sources provide the basic material for correction. Our method is based on the following assumptions: information needed to correct for scattering can be extracted from the energy spectrum at each pixel without any assumption concerning the source distribution, and two diametrically opposed energy spectrum acquisitions yield enough information on the source location in the diffusing medium for simultaneous correction for attenuation and scattering. RESULTS: Qualitative and quantitative evaluations of scatter correction by ANN demonstrate its ability to perform scatter correction from the energy spectra observed in each pixel. By using the energy spectra of incident photons detected in two diametrically opposed images, multilayer neural networks are able to perform a proper restitution of projection images without any assumption on geometry or position of radioactive sources in simple geometric cases. ANN corrections compare favorably to those provided by five of the most popular methods. A satisfying correction of both scatter and attenuation is observed for a human pelvis scan obtained during routine clinical practice. CONCLUSION: An ANN is an efficient tool for attenuation and Compton scattering in simple model cases. The results obtained for routine scintigrams in a much more complex situation are strong incentives for performing further studies.

Bone and Bones↗