PubMed HealthSearch

Biomedical subjects

G Endert

Publications and source records attributed to G Endert.

At least 19 recordsLinked to original sources

[Doppler ultrasound studies of long-term follow-up of children with hemolytic-uremic syndrome].

AIM: In the present study, we compared the diagnostic value of Doppler sonography with "B-Imaging" in the acute and chronical period of the HUS in children. METHOD: For this, we analysed the Doppler sonographic measurement (Acuson-128) from 3 patients in the acute stage of the disease and 14 patients after approximately 5 years. All patients examined in the chronic stage of the disease had been treated by peritoneal dialysis in the acute stage. As a control, the Doppler sonographic analysis of the A. renalis was performed in 25 healthy children. RESULTS: During the acute phase of the HUS, we found a significant increase in both the resistive index (RI) and the pulsatility index (PI). In addition, the diastolic current in the A. renalis was decreased or the blood flow was reversed. The kidney volume as well as the echo was increased in all cases. A recovery of the kidney observed as beginning diuresis coincided with a return to normal parameters in the Doppler sonographic measurement. In patients examined after 5 years, both the RI and the PI value was significantly (p < 0.01) different from the control group. These parameters correlate with the effective renal plasma flow, but not with the glomerular filtration rate. CONCLUSION: We conclude that in the acute stage of the HUS either "B-Imaging" or duplex sonography yield pathological parameter values. For the observation of the renal symptoms during the chronic phase of the disease, duplex sonography is clearly superior.

Acute Disease

[The evaluation of the adhesive properties of dental materials by using radioactive-labelled bacteria].

Dental materials with different surfaces were incubated with 111In-oxine-labelled bacteria Streptococcus mutans 20 min respectively 2 h, 6 h and 24 h. To determine the amount of the bacteria accumulated on the specimens we measured the radioactivity with a scintillation counter. The same measuring was done after decontamination by the help of ultrasonication. The comparison of activities shows that different dental material surfaces adhere different amounts of bacteria. The adhesive properties are material and time dependent, but the surface processing has a lower influence on the bacterial adherence. The lowest degree of bacterial adherence has the cobalt base alloy Gisadent KCM 83. On the other hand the highest remaining activity was found after decontamination of cobalt base alloy and PMMA resin Kallocryl A.

Adhesiveness

[Urokinetography in the diagnosis and follow-up of obstructive uropathy in children].

With regard to different paediatric urological diseases nuclear-medical urokinetography using the tracer 99m-Tc-DTPA can identify typical functional patterns. By means of 261 investigations on 240 children, retroperistaltic waves, initial pyeloureteral and the final ureterovesical conus, dysperistaltic waves and interrupting empty strips with lacing, constrictive peristalsis can be shown in comparison with the normal anterograde "stair" pattern. Moreover, UKG as a functional method makes it possible to control the therapeutic success of antibiotics in urinary inflammations, the situation after stone discharges and application of vegetative systemic drugs. In our opinion the operative procedure and the prognosis of megaureters can be assessed. Consequently urokinetography is among the important preoperative investigations in paediatric urology and in the follow-up programme after reconstructive urological operations. Nuclear-medical isotope investigation is without significant risk and yields many diagnostic details. The method can be recommended for functional urological diagnosis in children or teenagers with high frequency of follow-up investigations or in patients with contrast medium allergy. Finally, ureter physiology can be checked in patients subjected to bone scintigraphy. Clinical research is possible via UKG without additional radiation exposure.

Child

99mTc-labelling of leucocytes with 99mTc-DPO: a complex developed for myocardial imaging.

The lipophilic 99mTc-DPO complex, developed as a myocardial imaging radiopharmaceutical, was used to label leucocytes. After an incubation of 0.1 ml 99mTc-DPO (8 micrograms DMPE*2HCl) with mixed leucocytes in plasma, the labelling efficiency was over 70%. During incubation in 5 ml plasma, a loss of activity was found between 20% (1 h) and 35% (3 h) caused by elution. Disturbances of cell viability could not be found with the help of the chemiluminescence test. The in vivo recovery was determined in three dogs and was 45%-50% (0.5 h), 30%-36% (1 h), and 18%-24% (3 h). Autologous 99mTc-DPO-leucocytes were used on seven patients with suspected osteomyelitis, there were four true negative and three true positive results. The target/nontarget ratio determined by ROI in the positive cases was 1.8 to 2.5 at 3 h after injection.

Bone and Bones

[Nuclear medicine diagnosis in venous diseases of the extremities].

The 125I fibrinogen test and radionuclide venography have so far been the two standard methods of thrombosis diagnosis via nuclear medicine. Both methods have been developed further as a result of scientific and technical advances in recent years. Direct visualisation of thrombi with the help of 111indium thrombocytes is becoming increasingly important. Direct visualisation of thrombi can be made still easier by antithrombocytic antibodies. In case of contrast medium intolerance, and in diagnosing pulmonary embolism, radionuclide venography can still be useful in combination with lung perfusion scintigraphy, even if nonionic x-ray contrast media are increasingly introduced. The diagnostic possibilities offered by contrast medium venography in respect of precise morphological vascular imaging and function diagnosis, are complementary in many problems of venous diagnostics.

Blood Platelets

Percutaneous transluminal angioplasty (dilatation) of carotid, vertebral, and innominate artery stenoses.

Over a period of 5 years, 51 stenoses of brachiocephalic arteries were successfully dilated, and one subclavian occlusion recanalized in 42 patients. Among 24 patients there were 21 stenoses of the internal carotid artery, two stenoses of the common carotid artery, two stenoses of the innominate artery, five stenoses at the origin of the vertebral artery, and four stenoses of the subclavian artery. There were 17 patients who had stenoses of the subclavian artery. In 12 cases several arteries were affected. In 9 patients multiple (2-3) stenoses in these supraaortic arteries were dilated. In 4 cases bilateral dilatation of internal carotid arteries was performed. There were transient, minor complications in 2 patients.

Aged

[111Indium-thrombocyte scintigraphy and percutaneous transluminal dilatation (angioplasty) of supra-aortic vascular stenoses. A new method for deciding therapy and for follow-up control].

Scintigraphy with 111indium-marked autologous platelets has been used during percutaneous transluminal dilatation of supra-aortic arterial stenoses; there were 14 successful dilatations and one attempted dilatation. The material consisted of nine stenoses of the internal carotid artery, two stenoses at the origin of the vertebral artery and four stenoses of the first part of the left subclavian artery. Deposition of thrombi could be demonstrated by scintigraphy, both before and after catheter dilatation. The value of this method for deciding on the type of treatment and for observing the course of percutaneous dilatation of cerebral vessels is discussed.

Angioplasty, Balloon

[Application of ROC analysis to evaluating different methods of skeletal scintigraphy. Description of a practicable method].

Various techniques producing similar information can be compared by the use of ROC analysis. A practical and quick method of ROC analysis, which is otherwise very time-consuming, has been described for comparing various types of skeletal scintigraphy. Data is obtained by means of a phantom and evaluated with the help of a scheme which requires only moderate computational facilities.

Bone and Bones

[Exposure technics for computed scintigrams].

The technique of making copies on radiographic films or on multiformat cameras from computer scintigrams, computer tomograms, digital radiographs or other similar digital images should be carefully studied in order to make the best use of the characteristics of the film. Contrast transfer was studied using a nuclear medicine camera computer system with registration on radiographic film. Possible difficulties in obtaining copies and a simple software arrangement are described, which would influence contrast transmission.

Absorptiometry, Photon