Maximal airway pressures during crying in healthy preterm and term neonates.

Respiratory muscle strength can be assessed by measurement of maximal inspiratory (PIMAX) and maximal expiratory pressure (P(EMAX)) during crying. There are, however, relatively few data on P(IMAX) and P(EMAX) in infancy, particularly from those born preterm. Our aim was to investigate which factors influenced P(IMAX) and P(EMAX) in preterm and term infants. Forty infants, median gestational age 37 weeks (range 26-43) and birthweight 2.579 kg (range 0.956-5.180) were studied at a postconceptional age (PCA) of 38 weeks (range 32-44). None had respiratory problems. A facemask was placed firmly over the infant's mouth and nose and the infant studied during spontaneous crying. A pneumotachograph fitted snugly into the facemask and from a sideport airway pressure changes were measured. During crying, the distal end of the pneumotachograph was occluded for five breaths and at least three separate occlusions were made. The highest P(EMAX) value sustained for at least 1 s and the highest peak inspiratory pressure P(IMAX) were recorded. The mean P(IMAX) and P(EMAX) were higher in the term compared to the preterm infants (70 cmH2O +/-S.D. 19 versus 58 cmH2O +/-S.D. 17 P(IMAX) and 53 cmH2O +/-S.D. 13 versus 44 cmH2O +/-S.D. 19 P(EMAX), P< 0.05). Both P(IMAX) and P(EMAX) related significantly with postconceptional age, gestational age and weight, but not postnatal age. Stepwise regression analysis demonstrated P(IMAX) related independently with PCA and P(EMAX) with weight. These results suggest respiratory muscle strength is influenced by maturation at birth.

Airway Resistance↗

Resistance of pediatric and neonatal endotracheal tubes: influence of flow rate, size, and shape.

OBJECTIVE: The aim of this study was to determine the resistances of endotracheal tubes (ETTs) commonly used in neonatal and pediatric intensive care units and the relationship of resistance to flow rate, size, and shape of ETT. SETTING: Laboratory-based measurements. EVALUATION: We examined straight tubes with inner diameters between 2.5 and 6 mm and shouldered (Cole) tubes with inner diameter/outer diameter between 2.5/4 and 3.5/5 mm. We assessed ETT resistance at standard and "appropriate for patient use" lengths at flow rates from 0 L/min to 30 L/min. We used calibrated rotameters to control the flow of gas and proximal static pressure measured by using either an industrial draft gauge or a differential pressure transducer. The ETT resistance was calculated by dividing the proximal ETT pressure by the measured flow and expressed as the mean of three measurements at each flow rate. MAIN RESULTS: Resistance increased as ETT diameter decreased; at flows of 5 L/min and 10 L/min, the resistances of the 6 mm inner diameter ETT were 3.1 H2O/L/sec and 4.6 cm H20/L/ sec, respectively, and the resistances of the 2.5 mm inner diameter ETT were 81.2 H2O/L/sec and 139.4 cm H20/L/sec, respectively. Shortening an ETT to a length appropriate for patient use (e.g., a 4.0 mm inner diameter, from 20.7 to 11.3 cm) reduced its resistance on average by 22%. The resistance of a Cole tube was approximately 50% lower than that of a straight tube with an inner diameter corresponding to the narrow part of the shouldered tube. CONCLUSIONS: Our results suggest that the use of a small-diameter, straight ETT will significantly increase the work of breathing.

Airway Resistance↗

Comparison of predictors of extubation from mechanical ventilation in children.

OBJECTIVE: Unsuccessful extubation from mechanical ventilation increases mortality and morbidity. Therefore, the identification of an accurate predictor of successful extubation is desirable. This study was designed to determine whether the results of easily performed respiratory measurements, particularly if reported as "combined extubation" indices, were better predictors of extubation failure in a pediatric population than were readily available clinical data. DESIGN: Prospective observational study. SETTING: Tertiary pediatric intensive care unit. PATIENTS: All children who required mechanical ventilation for >/=24 hrs during a 12-month period and whose parents gave informed written consent. INTERVENTIONS: Respiratory function measurements were made (on average) 7 hrs (range, 0.2-25.0 hrs) before extubation. Arterial blood gas results were obtained immediately before extubation. The values of each predictor associated with maximum sensitivity and specificity were determined, and the areas under receiver operator characteristic curves were compared to determine the most accurate predictor of successful extubation. MEASUREMENTS AND MAIN RESULTS: A total of 47 children (mean age, 3.90 yrs; range, 0.10-17.3 yrs) were studied; extubation failed in 7. A low tidal volume (<7.5 mL/kg) and a low minute volume (<250 mL/kg) had the highest sensitivities (86% and 71%, respectively) and specificities (61% and 71%, respectively) in predicting extubation failure. The a/A ratio performed least well in predicting extubation failure (area under the receiver operating characteristic curve, 0.51). CONCLUSIONS: Volume measurements during pediatric mechanical ventilation may facilitate successful extubation.

Journal Article↗

Assessment of respiratory drive and muscle function in the pediatric intensive care unit and prediction of extubation failure.

BACKGROUND: Extubation failure can result from poor respiratory drive, impaired respiratory muscle function, or excessive inspiratory load. Measurement of airway pressure changes either during tidal breathing or after end-expiratory occlusion allows assessment of respiratory drive and muscle function. OBJECTIVE: To determine whether the results of airway pressure measurements characterized children who subsequently failed extubation and identify which test's results had the highest predictive performance. DESIGN: A prospective study. SETTING: Pediatric intensive care unit. PATIENTS: A sample of 42 stable intubated pediatric patients who were judged clinically ready for extubation. METHODS: A pneumotachograph was placed between the endotracheal tube and ventilator circuit. Airway pressure was measured from the pneumotachograph. The flow and pressure signals were amplified and displayed in real time on a laptop computer. During a temporary disconnection from the ventilator, the airway was occluded at end-expiration and the occlusion maintained for at least five breaths. From the first inspiratory effort during the occlusion, the pressure generated after 0.1 sec of occlusion (P0.1) and the largest negative pressure (PI) were calculated. From the series of breaths during the occlusion, the maximum P0.1 (P0.1 max) and maximum PI (PI max) were determined and P0.1/P0.1 max, PI/PI max and P0.1/PI max calculated. From spontaneous, tidal breaths during ventilatory support the pressure time product was calculated. RESULTS: Thirty-six (84%) of the children were successfully extubated. The children who failed extubation were characterized by a lower median P0.1 (p <.06), P0.1/P0.1 max, p <.05 and P0.1/PI max (p <.02). P0.1 and P0.1/P0.1 max and performed best in predicting extubation failure (areas under the receiver operator characteristic curves, 0.76 and 0.77 respectively). CONCLUSION: Assessment of P0.1 was the most useful airway pressure measurement in predicting extubation failure. Assessment of P0.1 may help to characterize children likely to fail extubation.

Journal Article↗

Comparison of the pressure time product during synchronous intermittent mandatory ventilation and continuous positive airway pressure.

OBJECTIVE: To compare the effect of continuous positive airway pressure (CPAP) with synchronous intermittent mandatory ventilation (SIMV) during weaning, by measurement of the pressure time product (PTP). The PTP is an estimate of the metabolic work or oxygen consumption of the respiratory muscles. PATIENTS: Forty children, median age 14 months (range 1 month to 17 years) were studied immediately prior to extubation. METHODS: The PTP, derived from airway pressure changes, was measured while the child received SIMV (with or without pressure support) and then CPAP. A pneumotachograph was placed between the endotracheal tube and ventilator circuit. Its flow signal was used to indicate the beginning and end of inspiration. Airway pressure was measured from the pneumotachograph and the area subtended by the pressure curve (PTP) calculated using a modified Labview programme. RESULTS: The median PTP was significantly lower on SIMV (17.1 cm H(2)O/sec/min, range 0.4 to 60. 5) compared to on CPAP (32.6 cm H(2)O/sec/min, range 0.1 to 116.7), p < 0.001. CONCLUSION: These results suggest SIMV, rather than CPAP, may be the more efficacious weaning mode in children, and that the time spent on CPAP during weaning should be minimised.

Adolescent↗

Adductor pollicis twitch tension assessed by magnetic stimulation of the ulnar nerve.

Many critically ill patients develop significant skeletal muscle weakness in the Intensive Care Unit (ICU), which ultimately may cause difficulties in weaning from mechanical ventilation and a protracted, expensive ICU stay. Reliable monitoring of muscle strength in this environment is difficult. The purpose of this study was to develop a reproducible, nonvolitional method of measuring adductor pollicis (AP) muscle function by magnetic stimulation of the ulnar nerve (MSUN) that could be applied to patients in the ICU and operating theater (OT). Fifty subjects (32 healthy control subjects [12 of whom were elderly], 12 ICU patients with critical illness [mean APACHE II score 20], and six otherwise healthy patients requiring minor surgery in the OT) received MSUN. In 12 of the normal subjects electrical stimulation of the ulnar nerve (ESUN) and MSUN were compared and AP twitch tension (Tw AP) and surface electromyogram (EMG) were measured. Close agreement was found between supramaximal Tw AP (median [95% CI] for MSUN 6.3 N [5-7.2 N] and ESUN 6.9 N [5.2-7.8 N] [p = NS]). Median (95% CI) values with MSUN for the 20 young and 12 elderly control subjects were 6.9 N (5. 3-7.4 N) and 7.1 N (4.4-9.8 N). Median (95% CI) Tw AP for the ICU group was 4.2 (2.2-6.7 N) and for the OT group was 5.8 (4-9.1 N). Tw AP was significantly reduced in ICU patients compared with age-matched controls (p = 0.01). MSUN can be used to measure neuromuscular function in both the laboratory and clinical settings including the ICU.

Adolescent↗

Assessment of neonatal diaphragm function using magnetic stimulation of the phrenic nerves.

A nonvolitional test to assess diaphragm strength in neonates has not been previously described. Our aim was to assess the feasibility of cervical (CMS) and anterior (AMS) magnetic stimulation of the phrenic nerves in neonates. Double circular stimulating coils (90-mm) were used. For CMS, one coil was placed over the cervical spine to bilaterally stimulate the phrenic nerve roots, whereas for AMS the coils were placed on the anterolateral aspect of the neck to allow unilateral and bilateral stimulation. Diaphragm contractility was assessed as transdiaphragmatic pressure (Pdi) measured with balloon catheters positioned in the midesophagus and stomach. Stimulus supramaximality was assessed by examining diaphragm twitch Pdi (TwPdi) across a range of stimulator outputs; 85, 90, 95, and 100% of maximum. Pressure signals were measured by differential pressure transducer and displayed in real time on a computer. Patients were studied supine during sleep. CMS was performed on seven neonates (mean gestational age [GA] 38 wk, range 33 to 40 wk) and AMS on 18 neonates (mean GA 37 wk, range 32 to 41 wk). The mean (SD) TwPdi with CMS was 2.5 (0.8) cm H(2)O. CMS was not supramaximal; reducing the stimulator output below 100% caused marked reductions in TwPdi, also the shape of the pressure waveforms suggested that CMS may not have activated the diaphragm alone. Mean (SD) TwPdi with AMS was 4.5 (1.3) cm H(2)O on the left, 4.1 (0.9) cm H(2)O on the right, and 8.7 (3.9) cm H(2)O for bilateral stimulation. The shape of the pressure waveforms suggested that AMS was more specific and a plateau in TwPdi at higher stimulator outputs indicated supramaximality. We conclude that AMS may provide a useful technique to assess diaphragm function in the neonate.

Diaphragm↗

Tidal breathing parameters in young children: comparison of measurement by respiratory inductance plethysmography to a facemask pneumotachograph system.

The ratio of expiratory time at tidal peak flow to total expiratory time (t(ptef)/t(e)) correlates with conventional measures of airway obstruction. It is usually assessed using a facemask and pneumotachograph system which may be poorly tolerated in young children and hence limits the usefulness of this technique. We therefore determined in young asthmatic children the accuracy of t(ptef)/t(e), using an uncalibrated respiratory inductance plethysmograph (RIP), and compared the results with those from a facemask-pneumotachograph system. We also assessed whether age influenced the agreement between measurements using the two devices. Forty-seven children aged between 1 month and 12 years were recruited: 39 were inpatients recovering from an acute wheezy episode, and 8 were recruited from the asthma clinic. All were receiving bronchodilators. Tidal breathing parameters t(ptef)/t(e), the duty cycle (t(i)/t(tot)), and respiratory rate were initially measured using the Respitrace alone and then simultaneously with both the Respitrace and the facemask-pneumotachograph system. Eight children did not tolerate the facemask, and in two others it was impossible to analyze the Respitrace trace due to artefacts. In the remaining 37 children, the reliability coefficients and coefficients of variation of the two techniques were similar. Similar values of t(i)/t(tot) and respiratory rate were obtained using the two devices. The mean t(ptef)/t(e) obtained using the Respitrace was lower than with the facemask-pneumotachograph system (P < 0.01), although this was age group-dependent (P < 0.05), as the difference was less apparent in the 1 to 2-year-old children than in other age groups. Application of the facemask-pneumotachograph system did not significantly influence the results obtained using the Respitrace. We conclude that uncalibrated respiratory inductance plethysmography can measure tidal breathing parameters as reliably as a facemask-pneumotachograph system in young asthmatic children, and is better tolerated than the pneumotachograph system. The results obtained using the two devices are not interchangeable.

Age Factors↗

Effect of hypercapnia on maximal voluntary ventilation and diaphragm fatigue in normal humans.

Relatively little is known about the combined effects of hypercapnia and fatigue on the human diaphragm. We examined the effects of acute hypercapnia and fatigue in seven subjects by measuring changes in transdiaphragmatic pressure (Pdi) elicited by cervical magnetic stimulation after 2 min maximal voluntary ventilation (MVV) while breathing air and also with the inspired PCO(2) increased to 8% for 12 min before and during the MVV. Diaphragm strength was assessed before and at 0, 20, 40, 60, and 90 min after the MVV in both studies with the subjects breathing air. There was no difference in the level of ventilation for each run. Mean (+/- SD) twitch Pdi (TwPdi) fell significantly (p < 0.01) at 20 min after the control and hypercapnic MVV; (30.4 [7.8] to 27.0 [8.1] cm H(2)O control and 30.3 [4.1] to 27.3 [5.0] cm H(2)O CO(2)) and remained significantly (p < 0.01) below baseline. The changes in TwPdi at 20 to 90 min were not significantly different between the control and CO(2) runs. The decrease in TwPdi at 0 min after MVV, however, was greater (15%) in the hypercapnic run than in the control run (8.1%) (p < 0.05) when compared with baseline valves. Hypercapnia does not intensify long lasting fatigue but may reduce diaphragm contractility immediately after MVV.

Adult↗

Quantification of the esophageal diaphragm electromyogram with magnetic phrenic nerve stimulation.

Measurement of the amplitude of the esophageal diaphragm compound muscle action potential (CMAP) could be useful for the diagnosis and monitoring of neuromuscular disease. However, quantification of the diaphragm CMAP has been hampered by difficulty in positioning the esophageal electrode at the diaphragm's electrically active center and many investigators report arbitrary units rather than voltage. To quantify the esophageal diaphragm CMAP we designed a multipair electrode which we evaluated during unilateral magnetic stimulation. The esophageal catheter consisted of four sequential electrode pairs. Overall the electrode spanned 17 cm and covered the entire electrically active region of the diaphragm. The diaphragm CMAP was simultaneously recorded from the four pairs at distances of 40, 39, 38, and 37 cm from the nose to the proximal electrode pair. Studies were undertaken in 10 normal subjects and 10 patients with diaphragm dysfunction. The amplitude of the CMAP (peak to peak) was defined as the average of five twitches recorded from the optimal pair of electrodes. The amplitude of the diaphragm CMAP elicited by unilateral maximal magnetic stimulation was 1.45 +/- 0.35 mV (mean +/- SD) for the right side and 1.68 +/- 0.47 mV for the left. When measured on different occasions the coefficient of variation (CV) was 8.6%. The amplitude of the CMAP measured from dysfunctional hemidiaphragms was much less than that measured from normal subjects. This study suggests that the diaphragm CMAP can be quantified using an appropriate esophageal electrode.

Action Potentials↗

Influence of acute lung volume change on contractile properties of human diaphragm.

The effect of stimulus frequency on the in vivo pressure generating capacity of the human diaphragm is unknown at lung volumes other than functional residual capacity. The transdiaphragmatic pressure (Pdi) produced by a pair of phrenic nerve stimuli may be viewed as the sum of the Pdi elicited by the first (T1 Pdi) and second (T2 Pdi) stimuli. We used bilateral anterior supramaximal magnetic phrenic nerve stimulation and a digital subtraction technique to obtain the T2 Pdi at interstimulus intervals of 999, 100, 50, 33, and 10 ms in eight normal subjects at lung volumes between residual volume and total lung capacity. The reduction in T2 Pdi that we observed as lung volume increased was greatest at long interstimulus intervals, whereas the T2 Pdi obtained with short interstimulus intervals remained relatively stable over the 50% of vital capacity around functional residual capacity. For all interstimulus intervals, the total pressure produced by the pair decreased as a function of increasing lung volume. These data demonstrate that, in the human diaphragm, hyperinflation has a disproportionately severe effect on the summation of pressure responses elicited by low-frequency stimulations; this effect is distinct from and additional to the known length-tension relationship.

Adult↗

Paired phrenic nerve stimuli for the detection of diaphragm fatigue in humans.

The transdiaphragmatic pressure (Pdi) elicited by paired bilateral phrenic nerve stimulation may be viewed as the sum of the Pdi values produced by the first (t1) and second (t2) stimulus. The Pdi at t2 (P[di,t2]) is a function of the interstimulus interval. A reduction in the ratio obtained by dividing Pdi,t2 at 10 Hz (P[di,t2,10]) by Pdi at 100 Hz (P[di,t2,100]) (t2(10:100)) has been proposed as a test of low frequency diaphragm fatigue. The aim of the present study was to establish whether this change could also be detected using paired cervical magnetic nerve stimulation (pCMS), and whether t2(10:100) was influenced by lung volume. We studied healthy subjects at functional residual capacity (FRC), at 0.5 and 1.0 L below FRC, and at 0.5, 1.0 and 1.5 L above FRC. The subjects were then subjected to a fatiguing protocol (2 min of maximal isocapnic ventilation (MIV)). Studies were repeated at FRC 20 and 60 min after MIV and between these times at 1.0 L below and 1.5 L above FRC. In the unfatigued state, t2(10:100) had a negative relationship with increasing lung volume (r2=0.98, p=0.002). After MIV there was a fall in the Pdi elicited by a single stimulus (mean fall at 20 min 17.9% and at 60 min 14.6%, p<0.03 for both). t2(10:100) fell by a mean 28.1% after 20 min and mean 22.9% at 60 min (p<0.03 for both). This change was mainly mediated by a fall in the P[di,t2,10]. The t2(10:100) was not able to distinguish between fatigue and acute hyperinflation. We conclude that paired cervical magnetic nerve stimulation may be used to detect low frequency diaphragm fatigue but that it remains important to control for lung volume.

Adult↗

Control of the respiratory cycle in conscious humans.

We studied in conscious humans the relative strength of mechanisms controlling timing and drive components of the respiratory cycle around their resting set points. A system of auditory feedback with end-tidal PCO2 held constant in mild hyperoxia via an open circuit was used to induce subjects independently to change inspiratory time (TI) and tidal volume (VTI) over a wide range above and below the resting values for every breath for up to 1 h. Four protocols were studied in various levels of hypercapnia (1-5% inspired CO2). We found that TI (and expiratory time) could be changed over a wide range (1.17 - 2.86 s, P < 0.01 for TI) and VTI increased by > or = 500 ml (P < 0.01) without difficulty. However, in no protocol was it possible to decrease VTI below the free-breathing resting value in response to reduction of auditory feedback thresholds by up to 600 ml. This applied at all levels of chemical drive studied, with resting VTI values varying from 1.06 to 1.74 liters. When reduction in VTI was forced by the more "programmed" procedure of isocapnic panting, end-expiratory of volume was sacrificed to ensure that peak tidal volume reached a fixed absolute lung volume. These results suggest that the imperative for control of resting breathing is to prevent reduction of VTI below the level dictated by the prevailing chemical drive, presumably to sustain metabolic requirements of the body, whereas respiratory timing is weakly controlled consistent with the needs for speech and other nonmetabolic functions of breathing.

Acoustic Stimulation↗

Control of expiratory time in conscious humans.

Combinations of 17 normal awake humans breathed mildly hyperoxic and hypercapnic gas mixtures via a pneumotachograph into an open circuit. Respiratory pattern was measured for each breath in real time by computer. Use of computer-controlled auditory feedback at a constant end-tidal PCO2 (PETCO2) allowed prolonged changes of 1) inspiratory time (TI) at constant inspired tidal volume (VTI), 2) VTI up and down in repeated steps at constant TI, and 3) expiratory time (TE) at constant VTI. The remaining variables were free to be determined by the subjects' automatic respiratory control mechanisms. We showed that TE changed in parallel with the change in TI despite constant VTI, TE did not change in response to step changes in VTI at constant TI, and large changes in TE had no influence on the subsequent TI, but VTI increased slightly as TE lengthened despite clamping. Time for expiratory flow (TE--end-expiratory pause) changed in parallel with TE in all protocols. Thus, in conscious humans, inspiratory timing has a direct influence on expiratory timing, independent of volume change and chemical drive, but expiratory timing has no influence on the inspiratory timing of the subsequent breath but has a small influence on volume.

Adult↗

Relation of hypocapnic symptoms to rate of fall of end-tidal PCO2 in normal subjects.

Hyperventilation is of little clinical relevance unless it causes symptoms. These are often non-specific. Their threshold for onset and relation to steady level of arterial (or its equivalent, end-tidal PCO2; PETCO2) are uncertain, and it has been suggested that they may relate better to the rate of fall of PCO2 than to the absolute level. We investigated this in nine normal subjects, who breathed to and fro through a pneumotachograph into an open circuit in which the concentration of CO2 could be varied. Tidal volume, respiratory frequency and ventilation was measured on-line by a Compaq computer, and PETCO2 at the mouth was measured by capnograph. Subjects overbreathed at a fixed rate and depth until symptoms consisting of dizziness, paraesthesiae and light headedness occurred. Then, without their knowledge and while they continued to overbreathe, inspired CO2 was increased to restore PETCO2 to normal and abolish symptoms, and was then withdrawn again over either approximately 0.1, 2.5 or 5 min until symptoms were again reported. The PETCO2 at this point was noted. The three protocols were performed in each subject in a random order and the same symptoms were reported each time. When averaged across all subjects, symptoms occurred at mean PETCO2 values of 20.3, 19.2 and 18.6 mmHg (2.71, 2.56 and 2.48 kPa), respectively. These were not significantly different, and it can be concluded that there was no influence of rate of fall of PCO2 on threshold for symptoms. Chest pain only occurred in one subject and may have a different mechanism.

Adult↗