PubMed Health⌕ Search

Biomedical subjects

G Fürst

Publications and source records attributed to G Fürst.

At least 19 recordsLinked to original sources

[Pulmonary embolism and deep vein thrombosis in the inferior vena cava affected by a rare anomaly].

Persistent left-sided inferior vena cava (VCI) is a rare venous anomaly, its prevalence being estimated at 0.2-0.5%. Thrombotic occlusion of a VCI has been reported in only a few of these cases. We report the case of a 24-year old woman who suffered an acute thrombosis in a left-sided VCI and recurrent pulmonary embolism. After thrombectomy the course was uneventful. The diagnostic approach and the treatment strategy are discussed with reference to the literature.

Adult↗

[Nonocclusive ischemia of the right colon].

BACKGROUND: Nonocclusive disease (NOD) is known to be a common cause of ischemic colitis, which is frequently underestimated. MATERIAL AND METHODS: A computer-assisted search of radiological reports at our institute over a period of 18 months, describing ischemic colitis of the ascending colon with an unimpaired perfusion of the superior mesenteric artery, was performed. RESULTS: A retrospective analysis of the clinical and radiological data of 14 patients was performed. In ten cases colonic ischemia was confirmed clinically or intraoperatively. Most of our patients needed intravenous catecholamines due to severe hypotension. However, no significant radiographic predictors could be identified. CONCLUSION: Awareness of NOD seems to be crucial. Especially in cases of acute abdominal pain associated with severe hypotension, renal insufficiency, or pancreatitis, one should include NOD as a differential diagnosis at an early stage.

Abdominal Pain↗

Prediction of relapse after antithyroid drug therapy of Graves' disease: value of color Doppler sonography.

Opinions differ regarding the indications for antithyroid drugs, radioiodine and surgery in patients with Graves' disease because the likelihood of long-term remission after medical treatment cannot be predicted. The aim of this study was to assess the value of quantifying thyroid blood flow in an attempt to predict outcome following withdrawal of antithyroid drug therapy. Spectral Doppler recordings were obtained from the thyroid arteries in 24 patients with Graves' disease at the time of diagnosis. Thyroid blood flow levels measured at the time of diagnosis of Graves' disease were correlated with outcome following withdrawal of medical treatment (mean duration of treatment: 14 months). Clinical follow-up for at least 18 months (range: 18 - 39 months) after antithyroid drug withdrawal was possible in 13 patients (12 women). Mean peak systolic velocity and volume flow rate values as well as thyroid volume measured at the time of diagnosis were significantly higher (139 cm/s, SD 46; 195 ml/min, SD 170; 52 ml, SD 18) in patients who relapsed after drug treatment compared with patients in remission (71 cm/s, SD 27; 67 ml/min, SD 61; 25 ml, SD 13). The correlation between thyroid blood flow measurements and thyroid volume was high (r = 0.79 - 0.96). Recurrence of disease could be predicted with a sensitivity of 71 % and a specificity of 100 % based on thyroid blood flow measurements. This preliminary data suggest that quantification of thyroid blood flow by means of Doppler sonography might be a useful tool to predict the outcome of Graves' disease following withdrawal of medical treatment and could be helpful in finding the adequate kind of therapy.

Adult↗

Exclusion of brain lesions: is MR contrast medium required after a negative fluid-attenuated inversion recovery sequence?

We hypothesized that in patients with negative fluid-attenuated inversion recovery (FLAIR) images T(2) weighted fast spin-echo (FSE) images and T(1) weighted spin-echo (SE) images before and after intravenous administration of gadolinium-based contrast medium display no pathology either. Thus, we assessed the negative predictive value of FLAIR images to rule out MR-detectable brain lesions. 1026 consecutive cranial MR examinations were reviewed. Routine MRI of the brain included T(1) weighted coronal imaging before and after administration of gadopentetate dimeglumine, axial T(2) weighted FSE and fast-FLAIR imaging. The FLAIR images were rated by two radiologists into categories of 0 (without pathologic changes) and 1 (with pathologic changes). Two other radiologists analysed the complete examination. In 284 MR examinations of the brain no abnormalities were found (28%). FLAIR-ratings were false-negative in four cases and false-positive in 30 cases. Sensitivity and specificity of the FLAIR sequence for MR-detectable brain lesions were 99.5% and 89.4%. The unselective application of gadolinium avoided one false-negative MR-reading and improved the sensitivity of the MR-examination from 99.5% to 99.6%. Positive and negative predictive values were 96.1% and 98.4%, respectively. The interobserver reliability was kappa=0.93 for the FLAIR-readers and 0.89 for the readers who rated the complete examination. In conclusion, negative FLAIR images provide a high negative predictive value for MR-detectable brain lesions. Thus, in patients with negative FLAIR images the unselective application of gadolinium seems to be unnecessary.

Adolescent↗

[Current diagnosis and therapy of non-occlusive mesenteric ischemia].

PURPOSE: Non-occlusive mesenteric ischemia (NOMI) is a life threatening disease. Therapy and prognosis depend upon the length of time elapsed between primary clinical manifestation and the time of definitive diagnosis and treatment. MATERIALS AND METHODS: NOMI was diagnosed by intraarterial selective angiography in four patients. After a bolus administration of 20 g Alprostadil (Prostavasin) into the superior mesenteric artery, intraarterial perfusion was continued with 60 microg Alprostadil/day via the catheter for three days. RESULTS: The mesenteric ischemia resolved in all patients. One patient recovered completely. Three patients recovered from mesenteric ischemia, but died subsequently due to complications of their primary diseases. CONCLUSION: When NOMI without perforation or necrosis of the bowel wall is suspected clinically, immediate intraarterial angiography is the diagnostic method of choice. If NOMI is confirmed, the appropriate treatment is the intraarterial application of potent vasodilators for several days. The diagnostic work-up in suspected NOMI and the impact of different radiological examinations are explained. The literature is reviewed.

Aged↗

[Kasabach-Merritt syndrome in giant hemangioma of the liver. A case report].

Kasabach-Merritt-syndrome is rare coagulation disorder with consumption coagulopathy caused by vascular malformations. We report the case of a 44-year-old woman with repeated severe bleeding complications after small and medium sized operations with normal results in the tests of plasmatic coagulation. After discovery of a giant hemangioma of the liver the diagnosis was established. Activation of coagulation was stopped preoperatively by i.v.-heparinization and curative treatment by right-sided hemihepatectomy followed.

Adult↗

[Modern diagnostic imaging: MR urography].

MR-urography presents a new diagnostic approach to the urinary system, resulting in images comparable to those known from i.v.-urography. T2-weighted MR-urograms demonstrate static fluid without ionizing radiation or nephrotoxic contrast media. The excretory renal function can be examined by the use of gadolinium-enhanced T1-urography. The degree and cause of ureteric obstruction can be diagnosed with high sensitivity and specificity. On the other hand, urolithiasis is frequently misdiagnosed by MR-urography and, in this case, spiral CT should be used. Pediatric or pregnant patients can be examined as well as donors before and patients after renal transplantation. Furthermore, in case of a tumor MR-imaging, including MR-angiography, is a potential diagnostic "all-in-one" approach.

Adult↗

Differential diagnosis of hyperthyroidism: Doppler sonographic quantification of thyroid blood flow distinguishes between Graves' disease and diffuse toxic goiter.

The aim of our study was to evaluate the usefulness of color duplex sonography to distinguish Graves' disease from diffuse toxic goiter. 24 patients with Graves' disease and 13 patients with diffuse toxic goiter underwent B-mode- and color duplex sonography of the thyroid gland. All patients had hyperthyroidism and elevated (99m)Tc-uptake. Spectral Doppler recordings were obtained at all thyroid arteries. Representative color flow maps of the thyroid gland were analyzed, calculating the percentage area of the thyroid gland, occupied by color pixels (color pixel density). The B-mode ultrasound pattern was subjectively assessed on a 4-point rating scale. In patients with Graves' disease the mean peak systolic velocity (PSV) (SD) was 110 (+/- 49) cm/s, the mean volume flow rate (VFR) was 123 ( +/- 67) ml/min and the mean color pixel density (CPD) was 33 (+/- 12) %. For patients with diffuse toxic goiter mean PSV (SD) was 43 ( +/- 9) cm/s (p < 0.001), mean VFR was 23 (+/- 10) ml/min (p < 0.001) and mean CPD was 9 (+/- 6) % (p = 0.007). CPD and spectral duplex recordings were positively correlated (CPD/PSV: rs = 0.77, CPD/VFR: rs = 0.75; p < 0.0001). No significant differences were observed concerning RI values. Sensitivity was 87% and specificity 92% for CPD and VFR and 87% and 100% for PSV. We conclude, that color duplex sonography can reliably distinguish diffuse toxic goiter from Graves' disease and therefore contributes significantly to the differential diagnosis of hyperthyroidism in diffuse thyroid disease.

Adult↗

Early postoperative tissue harmonic sonography of the thyroid gland.

PURPOSE: Fundamental gray-scale imaging (FGI) is known to be unuseful for thyroid imaging in the early postoperative setting. Thus, we evaluated the feasability of tissue harmonic imaging (THI) early after thyroid resection. MATERIAL AND METHODS: FGI and THI of the neck were performed in 48 consecutive patients 4 days after surgery. The examiner was blinded to patient diagnoses and types of surgery. FGI and THI examinations were stored on videotape and reviewed offline by two different readers who rated the quality of delineation of the organ borders and presence or absence of focal lesions. The results were compared to neck US performed 12 weeks after surgery. RESULTS: Delineation of the thyroid remnants in THI/FGI was rated to be excellent in 22/2, good in 11/9, poor in 3/16 and not visible at all in 4/13 patients. The correlation between THI-volumetry and control-volumetry was very high (r=0.81; p<0.0001). THI but not FGI depicted presence or absence of solid thyroid nodules with 100% accuracy. CONCLUSION: THI is a feasible method for thyroid US in the early postoperative setting. It permits volumetry of the residual thyroid tissue and accurately depicts nodules within the thyroid remnant.

Female↗

Estimation of antithyroid drug dose in Graves' disease: value of quantification of thyroid blood flow with color duplex sonography.

The purpose of this study was to evaluate if there is an association between the antithyroid drug dose that is needed to establish euthyroidism and thyroid blood flow measurements. A total of 23 Graves' disease patients with euthyroidism taking antithyroid drug therapy were enlisted to undergo spectral duplex sonography of the thyroid arteries and color-flow mapping of the thyroid gland. Color pixel density (CPD) was calculated with computer assistance from the color-flow maps. There was a strong correlation between the CPD and methimazole dose (rp = 0.79). Methimazole maintenance dosage could be predicted from CPD values with a coefficient of determination of 0.62. In conclusion, CPD measurements could be a useful tool for the clinical endocrinologist to estimate the antithyroid drug dose that is needed to maintain euthyroidism.

Adult↗

Long-term follow-up of left ventricular pacing via a posterior cardiac vein after mechanical tricuspid valve replacement.

Permanent cardiac pacing was recommended in a 66-year-old woman with mechanical prosthetic mitral and tricuspid valves. To avoid a thoracotomy, a conventional endocardial lead was inserted with a steerable stylet (Locator) into the posterior cardiac vein via the right cephalic vein. Four weeks later, lead dislodgement required reoperation. The lead position remained stable up to 29 months.

Aged↗

[Does tissue harmonic imaging allow early determination of postoperative thyroid volume?].

AIM: Therapy for endemic goitre after surgical resection depends on the residual thyroid volume. Post-operative changes have been known to impair the fundamental sonographic evaluation of residual thyroid tissue. It was our aim to determine whether THI is a feasible method for thyroid volumetry after surgery. METHODS: 48 patients underwent thyroidectomy, hemithyroidectomy, near total resection, or partial resection of the thyroid gland. In all patients THI of the neck was performed 4 (mean; range: 2-7 days) days after surgery using an Elegra sonographic device (Siemens, Erlangen, Germany) with a transmitted frequency of 3.4 MHz and received frequency of 6.8 MHz. The examiner was blinded to the patient's diagnosis and the type of surgery. The residual tissue volume measured by means of THI and intra-operative volumetry were both compared to sonographic volumetry 12 weeks after surgery, the latter serving as the gold standard. Accuracy of THI and intraoperative volumetry were tested for significant differences using a paired t-test. RESULTS: Volumetry by the surgeon was available in 26 patients (54%). The men error of THI volumetry was 2.4 ml (SD: 3.3 ml; maximum: 17 ml). The mean error of intraoperative volumetry was 1.4 ml (SD: 1.9 ml; maximum: 6 ml). The mean difference between THI and intraoperative volumetry was 1 ml (SD: 2.7 ml; maximum: 7 ml; p = 0.085). CONCLUSIONS: THI permits early volumetry of the residual tissue after thyroid surgery comparable with the intraoperative volumetry. Thus, THI may be helpful in guiding the substitution of thyroid hormones.

Adult↗

[Real-time compound imaging: improved visibility of puncture needles and localization wires as compared to single-line ultrasonography].

AIM: To compare the visibility of biopsy needles and localization wires using real-time compound imaging (SonoCT) and single-line ultrasound (SLU). METHODS: 14-18 G biopsy needles and 5 different localization wires with and without puncture needle were placed into cadaverous muscle in 4 different angulations (0, 12, 18 and 25 degrees). Sonography was performed with an ATL HDI 5000 sonography device with a 5-12 MHz linear array using single-line ultrasound and compound imaging with 3 and 9 frames (Comp3 and Comp9) from different viewing angles. Images of the needles were obtained in the longitudinal plane without changing depth, focus position, and gain settings between the measurements. The mean grey values of the needle (gv_n) and of the background (gv_b) were obtained from histograms. Contrast was calculated using the equation (gv_n-gv_b)/gv_b + gv_n). Mean contrast in single-line and compound images was compared for each angulation using a Student t-test. RESULTS: The mean contrast at 0 degree was 0.686 in single-line ultrasound. This was significantly higher than in Comp3 (0.62) and Comp9 (0.633) (p < 0.05) images. At 12 degrees no significant differences could be observed. At 18 degrees image contrast was significantly higher in compound images with 0.493 (Comp3) and 0.498 (Comp9), compared to SLU (0.433) (p < 0.05). At 25 degrees the difference between compound images (Comp3: 0.394; Comp9: 0.402) and SLU (0.306) was greatest (p < 0.0001). CONCLUSION: At 0 degree and 12 degrees visibility is very good for all tested materials. For steeper angulations contrast was partly critical in SLU and significantly enhanced with compound imaging. Thus, SonoCT may be useful to increase precision of ultrasound-guided percutaneous interventions.

Animals↗

[Radiological acute diagnosis in suspected perforation of the large intestine].

The last decade has seen changes in imaging procedures in patients with suspected colon perforation. Many traditional emergency imaging techniques have been replaced with helical CT, that can be performed with great accuracy, less patient discomfort and, probably, decreased cost. Because CT is more sensitive than conventional radiography in identifying subtle pneumoperitoneum, helical CT is ideally suited for rapid evaluation of the abdomen for patients with acute pain from suspected perforation. CT is often indicated when free air is seen at conventional radiography but perforation site is not clear. It is also indicated when air is strongly suspected despite normal abdominal radiographic findings.

Humans↗