PubMed Health⌕ Search

Biomedical subjects

G Famiglini

Publications and source records attributed to G Famiglini.

5 recordsLinked to original sources

Micro-SPE method for sample introduction in capillary HPLC/MS.

A new solid-phase extraction on-line device for micro-HPLC is presented. This device optimizes the injection of very dilute samples into a packed capillary column. It consists of two capillary, reversed-phase, HPLC columns of different length that can be linked together as a single chromatographic column. The first segment, only 2 cm long is connected to the HPLC injector. When disconnected from the longer column, several milliliters of an aqueous sample can be passed through at a high flow rate for fast trapping. On the basis of the retention mechanism, all suitable compounds are focused on the short column head in a sharp band. As soon as the chromatographic column is recomposed, the trapped analytes are eluted and separated at the optimal flow rate and gradient conditions. Due to the high preconcentration factor, trace-level analysis can be performed successfully. Different classes of analytes of various polarities and molecular weights can be determined, depending on the stationary phase and on the detector used. Some pesticides belonging to different classes were chosen to evaluate the performance of the device using an electron ionization mass spectrometer as HPLC detector. A fungicide in an irrigation canal water was determined at a concentration level of 4.5 microg x L(-1).

Journal Article↗

An efficient liquid chromatography--mass spectrometry interface for the generation of electron ionization spectra

The use of a new LC-MS interface (cap-EI), part of a Waters Integrity system, capable of generating EI spectra at micro flow rates is presented. The cap-EI interface relies on the production of a fine aerosol by means of a nebulizer and supported by a nitrogen jet. Sensitivity, response linearity, reproducibility, and LC compatibility of the interface were thoroughly examined using testosterone, caffeine, a mixture of antiinflammatory drugs, and 3,4-dihydroxybenzoic acid as test compounds. The interface is fully compatible with LC requirements such as high-water- and/or -buffer-content mobile phases. Reproducibility, high sensitivity in scan mode, as well, to produce library-searchable EI spectra, 2 orders of magnitude linearity, together with an intrinsic simplicity of the entire system are the key features of cap-EI interface.

Journal Article↗

Liquid chromatographic-mass spectrometric determination of phenolic compounds using a capillary-scale particle beam interface.

A capillary-scale particle beam interface was used to detect 18 phenolic compounds in red wine samples. This technique allows reproducible, library searchable electron ionization spectra at only 1 microliter/min mobile phase flow-rate for a sensitive detection of the analytes in complex matrices. The method makes use of a narrow bore, reversed-phase packed capillary column for sample separation. Detection limits were in the low picogram range for most compounds. Sensitivity and response linearity were evaluated for eight phenolic acids, which are often encountered in red wines. The phenolic compound composition was outlined in two red wines obtained using different aging processes.

Chromatography, Liquid↗

Use of nonvolatile buffers in liquid chromatography/mass spectrometry: advantages of capillary-scale particle beam interfacing.

The use of nonvolatile buffers like phosphate and citrate is usually incompatible with mass spectrometric detection or may heavily interfere with ion generation. In the case of conventional HPLC flow rates, the continuous buffer deposition produces fouling of the mass spectrometer ion source and may worsen the performance of any LC/MS interface as well. Our research group demonstrated that reducing the mobile phase flow rate in a particle beam interface improves the nebulization and enhances the overall performance. We have also assumed that such a modification may better handle potentially instrument harmful solvents or nonvolatile HPLC buffers. Since the presence of salts does not interfere with the electron ionization process, the particle beam interface can be considered, in principle, particularly suitable for those chromatographic separations that benefit from nonvolatile buffers. The microscale flow rate interface, developed in our laboratory, generates an aerosol from 1 microL/min of mobile phase flow rate. Under these conditions, the absolute amount of a nonvolatile buffer actually introduced into the system is approximately 1/1000 of that carried by a conventional HPLC column, slowing its deposition. This assumption was verified with a real-world application requiring the use of a phosphate buffer at a maximum concentration of 10 mM. It involved the determination of dexamethasone, an anti-inflammatory drug, in human blood after its administration to a patient. Several crucial mass spectral and chromatographic parameters were monitored during a 35-day period of intense use. Neither appreciable signal modification nor evident buffer deposition was observed during the test period, with only a normal and limited run-by-run and day-by-day variation of the instrument response.

Anti-Inflammatory Agents↗

New trends in the application of electron ionization to liquid chromatography-mass spectrometry interfacing.

I. Introduction 88 II. Cap-EI Interface 90 A. Interface Performance 92 III. Direct-EI Interface 93 A. Interface Performance 97 IV. Conclusions 103 Acknowledgments 103 References 103 --Two recent approaches for coupling capillary scale liquid chromatography and electron ionization mass spectrometry are reviewed and discussed. The first one, Cap-EI, is the latest evolution of the micro-scale particle beam interface, in which the nebulizer has been optimized to overcome the limitations of the former approach, in terms of sensitivity and linearity. It can be easily hosted in pre-existing instruments without major modifications and can use helium and the less-expensive nitrogen to generate library-matchable electron ionization spectra. The second one is a miniaturized interface for nano- and micro-HPLC, in which the interfacing process takes place into a suitably modified ion source. Because the eluate from the column is completely transferred into the ion source for ionization, superior sensitivity, linearity, and reproducibility are obtained. No signs of chemical ionization are observed at flow rates up to 1.5 microL/min. These two interfaces demonstrate that electron ionization can be successfully used for the analysis of small-medium molecules of various polarities, and also at the trace level. The possibility to record library-matchable electron ionization spectra offers the analyst a powerful tool that can be particularly useful in real-world applications.

Caffeine↗