PubMed Health⌕ Search

Biomedical subjects

G Farr

Publications and source records attributed to G Farr.

At least 37 records · Page 2Linked to original sources

The non-contraceptive effects of the levonorgestrel-releasing intrauterine device.

Clinical trials have consistently shown that the IUD that releases 20 micrograms levonorgestrel daily (LNG-IUD-20) has a contraceptive efficacy comparable to, if not surpassing, the Copper T380 and the Multiload Copper-375 IUDs. The focus of this review is the device's non-contraceptive effects--the beneficial ones, such as reduction of menorrhagia, a therapeutic effect on dysmenorrhea, and prevention of ectopic pregnancy, as well as the deleterious ones, such as amenorrhea, spotting and irregular bleeding, hormonal side-effects, and functional ovarian cysts. Also discussed are the possibility of a preventive effect on pelvic inflammatory disease, the effects of the IUD on postpartum/lactating women, fertility return after removal and other safety issues. In general, the LNG-IUD-20's non-contraceptive benefits are substantive, carry important medical and public health implications, and far outweigh the device's deleterious effects, which are either medically mild or transient in nature, and can usually be managed satisfactorily by counseling. A better understanding of these effects, both beneficial and deleterious, of this hormone-releasing IUD should lead to more effective patient counseling, which, in turn, should improve user quality of life, minimize unnecessary removals, and maximize continuation of use.

Female↗

An analysis of the personal reasons for discontinuing IUD use.

The objective of this study was to evaluate possible factors associated with discontinuing use of TCu 380A IUDs due to personal reasons among 2748 users. Overall, a total of 88 subjects discontinued using the TCu 380A IUD within 12 months postinsertion for personal reasons. The most common reasons were planned pregnancy (32%) and husband or family opinion against IUD use (26%). The gross cumulative 12-month life table discontinuation rate for all personal reasons was 4.0 per 100 women. Having no education and/or living in a rural area were the sociodemographic characteristics associated with an increased risk of discontinuation for personal reasons. Effective and regular counseling about IUD use, especially among illiterate women, may help prevent IUD discontinuations related to personal reasons.

Attitude↗

Contraceptive efficacy of the Copper T 380A and Copper T 200 intrauterine devices: results from a comparative clinical trial in six developing countries.

The clinical performance of the Copper T 380A (TCu 380A) and the Copper T 200 (TCu 200) intrauterine devices (IUDs) was evaluated for 12 months in a group of women who had one of the two IUDs inserted. Results are from a multicenter randomized clinical trial at one site in each of six developing countries. The pregnancy rate with the TCu 380A IUD was significantly lower than the pregnancy rate with the TCu 200 IUD at 12 months (0.5 and 2.6 per 100 women, respectively, p < 0.01). No statistically significant differences between the two study IUDs were found with regards to expulsion or removals due to bleeding/pain, personal, medical, or planned pregnancy. The TCu 380A IUD did not have a disproportionately higher incidence of side effects such as intermenstrual bleeding or pain, inflammations or infections, or insertion-related events compared to the TCu 200 IUD. TCu 380A IUD users, however, were significantly more likely to report increased dysmenorrhea than were TCu 200 IUD users. The performance of the TCu 380A IUD in preventing pregnancy during this trial indicates that this IUD may be a better option than the TCu 200 IUD for women wishing to practice effective, long-term, reversible birth control without having to resort to hormonal methods.

Contraception↗

Clinical performance of the TCu 380A and TCu 220C IUDs in four developing country family planning clinics.

The clinical performance of the Copper T 380A (TCu 380A) and the Copper T 220C (TCu 220C) intrauterine devices (IUDs) were evaluated for 12 months in a group of women who had one of the two IUDs inserted. Results are from a randomized clinical trial conducted at four collaborating research sites located in two developing countries. The gross cumulative life-table pregnancy rate of the TCu 380A IUD was found to be lower than that of the TCu 220C IUD at 12 months (0.3 and 0.8, respectively), although this difference was not statistically significant (p > 0.05). Statistically significant differences between the two study IUDs were not found with regard to IUD expulsion or IUD removal due to bleeding/pain, personal reasons, medical reasons, or planned pregnancy. No statistically significant differences were observed in the frequency of experiencing menstrual disturbances (i.e., dysmenorrhea, intermenstrual pelvic pain or intermenstrual bleeding) between the two IUD groups. These data suggest that the TCu 380A and TCu 220C IUDs are both appropriate options for contracepting women. The TCu 380A IUD, however, may be a more appropriate option for those women wishing to space births over a longer period of time.

Adolescent↗

Clinical evaluation of the TCu 380A IUD at six Latin American centers.

Compared with other contraceptive methods such as sterilization and oral contraceptives, the prevalence of IUD use in Latin American countries is relatively low. This study evaluated the clinical performance of the TCu 380A IUD in six Latin American clinics to determine whether its performance was a determining factor in its low prevalence, and to provide efficacy and safety data based on local data sets to Latin American service providers. The 12-month unintended pregnancy rate ranged from 0.0 to 1.7 per 100 women and the 12-month discontinuation rates for all reasons, from 3.3 to 21.0 per 100 women. Statistically significant differences in discontinuation rates were observed among clinics, and could be explained, in part, by the different sociodemographic and clinical characteristics of women attending the clinics. The overall performance and acceptability of the TCu 380A IUD was considered satisfactory and comparable to those reported from other countries. Thus, the low prevalence of IUD use in Latin America is probably related to barriers to its use rather than its clinical performance.

Adult↗

Contraceptive efficacy and acceptability of the female condom.

OBJECTIVES: The purpose of the study was to determine the contraceptive efficacy of the female condom and to provide data about the device to the US Food and Drug Administration. METHODS: The clinical trial was conducted at six US sites and three sites in Latin America. Eligible subjects were in mutually monogamous relationships and agreed to use the female condom as their only means of contraception for 6 months. RESULTS: A total of 328 subjects contributed to the analysis of contraceptive efficacy. Twenty-two US subjects and 17 Latin American subjects became pregnant, yielding 6-month gross cumulative accidental pregnancy rates of 12.4 and 22.2, respectively. During perfect (consistent and correct) use of the method, the 6-month accidental pregnancy rates were 2.6 and 9.5 for the US and Latin American centers, respectively. There were no serious adverse events related to the use of the method. CONCLUSIONS: The female condom provides contraceptive efficacy in the same range as other barrier methods, particularly when used consistently and correctly, and has the added advantage of helping protect against sexually transmitted diseases.

Adult↗

The intrauterine device in the present and future.

Good counseling and better selection of candidates would result in the intrauterine device's (IUD) safer use. Age and parity of the IUD acceptor do not seem to be associated with an increased risk of pelvic inflammatory disease (PID). The newer generation of copper- and hormone-releasing IUDs are associated with improved safety and efficacy.

Aftercare↗

Interactions between intrauterine contraceptive device use and breast-feeding status at time of intrauterine contraceptive device insertion: analysis of TCu-380A acceptors in developing countries.

OBJECTIVE: This paper is a reassessment of earlier findings from a preliminary analysis of data from a multicenter international trial regimen on breast-feeding and non-breast-feeding women in which events related to insertion, expulsion, and removal of the TCu-380A intrauterine contraceptive device (ParaGard 380) were investigated. STUDY DESIGN: Performance of the TCu-380A through 12 months after insertion was compared with life-table rate analysis, chi 2, Fisher exact test, or Student's t test. Variables were events reported during intrauterine contraceptive device insertion and events throughout the 12 months of study participation by breast-feeding status. RESULTS: Breast-feeding among intrauterine contraceptive device users was associated with fewer insertion-related complaints and lower removal rates for bleeding and pain. No uterine perforations were reported throughout the study. CONCLUSION: Differences in the performance of the TCu-380A intrauterine contraceptive device suggest physiologic effects associated with lactational amenorrhea. The TCu-380A intrauterine contraceptive device is a viable option for women breast-feeding at the time of intrauterine contraceptive device insertion.

Adult↗

Prevention of IUD-related pelvic infection: the efficacy of prophylactic doxycycline at IUD insertion.

It is believed that much of the small increased risk for developing pelvic inflammatory disease (PID) associated with the use of an intrauterine device (IUD) appears to be caused by bacterial contamination of the endometrial cavity at the time of insertion. Previous research suggests that use of prophylactic antibiotics immediately prior to IUD insertion may reduce the risk of developing PID. This paper presents results from a randomized clinical trial of 1485 women in Ibadan, Nigeria evaluating the effectiveness of 200 mg of doxycycline (versus placebo) given orally at the time of IUD insertion in reducing the incidence of PID during the first three months of IUD use. Rate of PID infection in the doxycycline-treated group was not significantly lower than that in the placebo-treated group. The rate of unscheduled IUD-related visits to the clinic also was not significantly lower among the doxycycline-treated group. However, the incidence of PID was low (21 cases) for both study groups. Aseptic conditions during IUD insertion, follow-up visits with short intervals to monitor health, and treatment of opportunistic infections may have reduced the potential of PID within this population.

Administration, Oral↗

A comparative clinical trial of the TCu 380A, Lippes Loop D and Multiload Cu 375 IUDs in Indonesia.

The Copper T 380A (TCu 380A), Lippes Loop D (LLD) and the Multiload Cu 375 (MLCu 375) IUDs were evaluated for safety and efficacy in a multicenter randomized clinical trial in Indonesia. A total of 2992 women were enrolled into the study and data for 2845 women were analyzed (147 cases did not meet protocol criteria). Although study IUDs were randomly assigned, LLD users in this study were older and of higher parity than TCu 380A and MLCu 375 users. The 24-month gross cumulative life-table pregnancy rates for TCu 380A, LLD and MLCu 375 users were 1.2, 2.2 and 2.7, respectively. The 24-month expulsion rates for TCu 380A, LLD and MLCu 375 users were 6.7, 7.5 and 5.3, respectively. Overall, 24-month continuation rates were 85.5%, 85.0% and 85.4% for the respective device groups. Differences in both gross and age- and parity-adjusted life-tables rates for the major outcome variables were not statistically significant at 24 months postinsertion. The study suggests that the TCu 380A, LLD and MLCu 375 IUDs seem to be safe and effective contraceptive options for Indonesian women.

Adolescent↗

The effect of adding copper onto Lippes Loop IUDs: results from a ten-year study in Yugoslavia.

The present study is the first randomized ten-year comparison of the standard, non-medicated Lippes Loop D and the same device with the addition of 200 mm2 of copper in the form of copper sleeves. The devices were randomly inserted immediately after first trimester medical termination of pregnancy. Out of 400 postabortal IUD insertions, 371 were followed for up to ten years. Gross cumulative life-table accidental pregnancy rates after one year of use were 0.56 for the copper-bearing Lippes Loop and 4.63 for the standard Lippes Loop. After two, four and ten years, these rates were 1.24, 2.70 and 3.62 and 6.03, 7.58 and 14.94, respectively (in all comparisons, rates were significantly different at the 0.05 level or lower). At each time interval, expulsion/displacement rates were 4.49, 4.49, 5.23 and 6.32 for the copper-bearing Lippes Loop and 12.61, 13.29, 15.46 and 19.79 for the standard Lippes Loop (rates were significantly different at the 0.01 level or lower). Differences in removal rates for bleeding and/or pain were not significantly different at any of the follow-up intervals. The lower event rates for copper-bearing Lippes Loop D users indicates that the addition of copper to the Lippes Loop IUD may result in better long-term efficacy profiles for this device among postabortal women. The results also suggest that large, medicated IUDs may be more efficacious for women with larger uteri who often experience higher failure rates due to expulsion or displacement of smaller IUDs into the lower uterine segment.

Adolescent↗

Detection of hepatitis C virus sequences in liver tissue by the polymerase chain reaction.

Although sensitive assays for serum antibodies to hepatitis C virus (HCV/anti-HCV) have been developed recently, the relation of anti-HCV to HCV infection of the liver has not been clarified. Therefore, we determined the presence of HCV RNA by the reverse transcription-polymerase chain reaction (PCR) in liver biopsy specimens of 21 patients with chronic liver disease and 5 control patients. RNA was extracted from frozen liver tissues by the guanidinium method, HCV cDNA was synthesized by reverse transcription, and core region and NS3 region sequences were amplified by PCR. The sensitivity and specificity of the reaction was significantly enhanced by double PCR with nested primers followed by Southern blotting with an HCV specific oligomer probe. NS3 region sequences were detected in the liver specimens of 12 out of 15 anti-HCV positive patients. Core region sequences were detected in 9 patients, all of whom were also positive for NS3 region sequences. HCV sequences were not detected in 11 anti-HCV negative patients. In all cases, the integrity of the extracted RNA was demonstrated by successful amplification of albumin mRNA as internal control. Our findings demonstrate the feasibility of the reverse transcription-double PCR method followed by Southern blotting for the detection of HCV sequences in liver tissues. In this system, the detection rate of NS3 region sequences is higher than that of core region sequences. There is a statistically significant correlation between high titer anti-HCV antibodies in serum and NS3 region sequences in liver tissue. However, not all anti-HCV positive patients had HCV positive hepatitis. The reverse transcription-polymerase chain reaction for HCV sequences on liver tissue extracts may reveal valuable information on the diagnosis of HCV infection and the pathogenesis of chronic hepatitis C.

Base Sequence↗

Complete and partial glycophospholipid anchors are found on a fusion protein consisting of luteinizing hormone beta subunit followed by a carboxyl-terminal domain of Thy-1.

The Thy-1 antigen is anchored to the cell surface by a carboxyl-terminal glycophospholipid moiety. To investigate the extent of anchor addition which occurs when such proteins cannot move efficiently to the cell surface, we have expressed a recombinant fusion protein composed of 107 amino-terminal amino acids of bovine luteinizing hormone beta subunit and 46 COOH-terminal amino acids of murine Thy-1 (Thy-1.2 allele). Although the limited amount of fusion protein transported to the cell surface is glycophospholipid-anchored, most of the protein accumulates in an intracellular, endoglycosidase H-sensitive form. The intracellular protein has an unusual structure that contains ethanolamine but does not bind detergent, suggesting either that anchor addition proceeds via a hydrophilic partial intermediate, or that anchor-degradative enzymes exist along the secretory path.

Animals↗

Do retroverted uteri adversely affect insertions and performance of IUDs?

A large international multi-center IUD data set (N = 5520) coordinated by Family Health International was analysed to determine if the uterine position of a woman (anteverted, mid-positioned or retroverted) affects the ease of IUD insertion and if knowledge of uterine position would diminish insertion-related problems and improve IUD performance. Findings showed that insertion-related events were rare irrespective of uterine position. Women with retroverted uteri were not associated with higher termination rates for accidental pregnancy, expulsion or removal for bleeding and/or pain after 12 months of IUD use, as compared to the other two uterine position groups. All insertions in this data set were performed by experienced obstetricians/gynecologists, and our findings suggest that women with retroverted uteri should be equally good candidates for IUD contraception.

Adult↗

Is the copper T 380A device associated with an increased risk of removal due to bleeding and/or pain? An analysis.

Previous studies have consistently shown that the family of the Copper T 380 devices is more effective in preventing accidental pregnancies than the inert, as well as most other, if not all, copper devices. However, a number of these studies also reported a higher removal rate due to bleeding and/or pain for the TCu 380A than for other devices. The programmatical importance of these findings prompted us to analyze the international multi-center randomized clinical trial datasets to examine this question on the new TCu 380A (ParaGard) recently marketed in the U.S. Our results, while confirming the inherent superior efficacy of the TCu 380A, did not reveal a significantly higher removal rate because of bleeding and/or pain among TCu 380A users than among users of the comparative devices, which included the Lippes Loop D, the TCu 200, the TCu 220 and the Multiload Cu 250 devices.

Adolescent↗

Postpartum IUD contraception--a review of an international experience.

Postpartum insertion of intrauterine contraceptive devices (IUDs) performed while women are still in hospital has a number of advantages. Earlier reports, however, generally associated this procedure with high expulsion rates. Recent studies, on the other hand, have shown that if IUDs are inserted immediately (within 10 minutes) after placental delivery, it is safe and effective. In some experienced centers, fairly low expulsion rates are reported. In this paper the experiences with postplacental IUD insertions from international studies are reviewed, the lessons we have learned from these experiences summarized, and future research directions suggested.

Cross-Cultural Comparison↗