Intraoperative blood salvage: a new artificial organ?

Optimal blood supply is critical to modern medical practice. Among the different possibilities of improving the quality and safety of blood, it is generally felt that autologous donation has played an important role and has contributed to changing transfusional practices, mainly since the appearance of HIV and HCV on the blood transfusion scene. At the San Martino Hospital Immunohematology Service, the autotransfusion era began in 1985. Autologous predeposit donation was the first to be introduced, followed by intentional perioperative hemodilution, intraoperative blood salvage with DFC apparatuses and lastly post-operative blood salvage. From about 200 autologous donations in 1985 we reached 5,372 in 1993 and more than 6,000 autologous donations are expected for 1994. Only 189 intraoperative blood salvages, were carried out in 1986, 593 in 1989, 1,207 in 1993 and more than 1,500 blood salvage sessions are anticipated for 1994. In the meantime, the total number of homologous RBC units employed in the Hospital dropped from 45,000 in 1985 to 18,000 in 1994, with the Onco-hematological Divisions using approximately 10,000 units of packed RBC.

Blood Platelets↗

Preparation and storage in Plasma-Lyte A of platelets collected with the cell separator CS3000 Plus equipped with the PLT30-separation and TNX6 collection chambers.

The last five years have been characterized by the presentation of new cell separators the main task of which is the collection of high yield-high quality platelets. The CS3000 is an old apparatus which has undergone rejuvenation to sustain the assault of its new competitors. The CS3000 Plus Omnix system is the latest version to be offered along with a combination of TNX-6 separation/PLT30 collection chambers for optimal platelet collection. In this paper we present our results with this apparatus and configuration after its adaptation to the collection and storage of platelets in a non-plasma medium, the Baxter Plasma-Lyte A. After separation the platelet product (PC) was left in the collection chamber and resuspended with 200 ml of Plasma-Lyte A instead of being resuspended in autologous plasma as usual. Plasma was collected in a separate bag (400-450 ml) for transfusion or fractionation purposes. PC quality was assessed by evaluating the platelet yield (4.17 +/- 1.8 x 10(11), and the WBC contamination (4.8 +/- 2.6 x 10(5)). The presence of platelet aggregates (platelet count after aggregate fixation with formalin/platelet count after disaggregation in EDTA), the aggregation induced by ADP, collagen and ristocetin, the hypotonic shock response and the stability of membrane glycoproteins (CD 62 - 62 - 63 - 36- 42b - 51) were measured in the preapheresis samples and in the PC immediately after, 24 and 72 hours after collection. These results were totally satisfactory as was the post-transfusion survival measured as corrected count increment in 10 transfusions to non refractory patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Diphosphate↗

Single-donor platelet concentrates produced along with packed red blood cells with the Haemonetics MCS 3p: preliminary results.

There has been an increasing interest in recent years over the qualitative superiority of single-donor platelets in the management of hemato-oncologic patients. The reasonable desire of both patients and physicians to limit the risks of transfusion along with the need for limiting the costs involved in this kind of therapy have led to application of multicomponent donations both in terms of double platelet concentrates and double products such as red blood cells (RBC) and platelets from the same donor. Single donor platelets and RBC have been collected in a semi-automated mode and only the very recent introduction of the Haemonetics MCS 3p with its SDP/RBC protocol provides a totally closed-system automated protocol for this combined collection. Twenty procedures have been carried out so far at our unit. In a mean of 87 minutes (6-7 passes), a mean of 3.1 x 10(11) platelets were collected along with approximately 220 mL of packed RBC. The leukocyte contamination of the platelet product was in the range of 0.4-1.1 x 10(7) (99% lymphocytes), and the quality of platelets was very satisfactory as measured by the hypotonic shock response, aggregation induced by ADP, collagen and ristocetin, morphology score, and membrane glycoproteins modifications. Equally satisfactory was the quality of the RBC concentrate, suspended in 80 mL of SAG-M, with a total hemoglobin (Hb) content approaching 55 g as compared to the normal Hb content of a standard RBC concentrate that is approximately 62 g.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Increased intestinal sugar permeability after challenge in children with cow's milk allergy or intolerance.

The diagnosis of cow's milk allergy or intolerance (CMAI) is based on clinical improvement on exclusion diet and relapse after challenge with milk. The aim of this work was to investigate the value of the cellobiose/mannitol (C/M) sugar permeability test, performed before and after cow's milk challenge, as a tool for the diagnosis of CMAI. Thirty-two patients underwent milk challenge at a median age of 13 months (range 3-84 months). A dual sugar (C/M) permeability test with an iso-osmolar solution was performed before and 24 h after challenge. Of the 10 patients who developed symptoms after challenge, nine showed increased postchallenge C/M ratio, whereas such an increase was observed in only one of the 22 nonrelapsed subjects. The postchallenge C/M ratio increase in relapsed subjects is to be attributed to both higher cellobiose and lower mannitol urinary excretion. These results suggest the use of the sugar permeability test, in addition to clinical observation, as an aid in the evaluation of provocation tests in infants with suspected CMAI.

Animals↗

Excel: a new cell separator in its very first clinical application.

BACKGROUND: The evolution of technology has been one of the most interesting features that has accompanied thrombocytapheresis throughout the years. In this presentation we report on the preliminary results obtained with Excel, a third-generation cell separator that is presently in its early experimental phase. MATERIAL AND METHODS: So far only 15 thrombocytapheresis procedures, 2 of which of the single-needle type, were carried out on 15 healthy donors processing 4 liters of blood (2.8 liters in single needle). RESULTS AND CONCLUSIONS: The results were satisfactory since the average platelet yield was 4.7 x 10(11). The leukocyte contamination was 0.8 x 10(6) and the RBC contamination 0.4 x 10(7). The platelet efficiency per minute was 6.5 x 10(9), and the run time average 72 min. As to the quality of the product the very first results of platelet aggregation, relative to pre-apheresis, were 78% in response to ADP 6 microM; 106 and 102% in response to collagen 4.5 micrograms/ml and ristocetin 1.5 mg/ml, respectively. Essentially no platelet aggregates were found in the platelet products (Wu-Hoak ratio: 0.91).

Adult↗

Donors thrombocytapheresis with last generation cell separators.

An exciting, fast moving and promising field remains the use of plasma-free synthetic medium for platelet storage (10, 11), that along with the potential for getting more plasma for therapeutic needs, might also improve the quality of stored platelets. Addition of acetate to solution, may be the way to obtain these results. An astonishing fact is that citrate remains the only anticoagulant for platelet collection, and remains as well the only real cause of donor discomfort during thrombocytapheresis.

Blood Donors↗

Plasma exchange: the cost/benefit ratio and the critical revision of indications.

The number of conditions that can benefit from Plasma-Exchange (PE) continues to grow. We have recently added to the list the Cyclosporin-A induced hypertrygliceridemia and myoglobinuric acute renal insufficiency. Such as any therapeutic measure for PE, four evolutive phases can be recognized: the discovery and research, the confirmation of indications, the routine applications and the decline, when new more powerful tools are offered by culture or technology. We have participated in the first three phases during the last 20 years. Not necessarily all experiences were favourable. Nonetheless, we feel that, for the time being, a hemapheresis unit is an absolute necessity for a medium - sized hospital even if only therapeutic procedures are carried out. The phase four, decline of interest and applications, cannot be foreseen. Finally the ability of PE to shorten substantially the length of hospital stays along with the ease with which procedure can be performed on ambulatory patients, substantiate a favourable cost/benefit ratio for this therapeutic modality.

Humans↗

The organization of the autotransfusion-perioperative blood salvage at San Martino Hospital.

Autologous transfusion is playing an important role in modern transfusion medicine. At San Martino hospital we use a combination of manual and mechanical techniques in order to improve autotransfusion procedures, control the hypertransfusion and avoid waste. Our autotransfusion program has determined a 55% reduction in the red cell concentrates used (from 42,000 in 1985 down to 19,400 in 1992). Proper training, cultural improvements and new applications on autotransfusion procedures will permit a better use of blood with less transfusion related complications, until a suitable substitute for blood will be available.

Blood Loss, Surgical↗

Single-needle thrombo-cytapheresis with the Fresenius AS 104.

BACKGROUND: The Fresenius AS 104 cell separator has recently met some popularity in European apheresis units for the quality of the platelets obtained with the totally automated double-needle procedure. MATERIALS AND METHODS: Taking advantage of the machine's flexibility we have developed a new automated procedure for single-needle thrombocytapheresis (SNP). So far 61 SNP were carried out. From donors having a platelet precount of 2.74 x 10(5) an average of 3.8 x 10(11) cells were collected by processing 2.5 liters of blood in a run time of 83 min. RESULTS AND CONCLUSIONS: The leukocyte and erythrocyte contaminations were 2.7 x 10(7) and 3.5 x 10(7), respectively. Only 2 products did contain less than 3.5 x 10(11) platelets, and 7 procedures were complicated by minor signs of hypocalcemia. With minor modifications this SNP is presently offered on a routine basis to our platelet donors.

Adult↗

Plateletpheresis with the new Fresenius AS 104 blood cell separator.

Among the many blood cell separators introduced into the international market in these last few years, the Fresenius AS 104 represents an advanced and safe thrombocytapheresis machine whose development took advantage of extensive worldwide experience with blood cell separation. Nonetheless the AS 104 has generated most interest in West Germany and most, if not all, the studies published on its platelet collection efficiency have been carried out in that country. It is normally reported that from 2.7 to 3.5 x 10(11) platelets can be collected in approximately 80 minutes. Since these results could not be duplicated routinely in our hemapheresis unit, we set up a study by modifying the standard procedure. It was possible to reduce the procedure time and to collect platelet concentrates containing more than 4 x 10(11) cells on a routine basis by using the following procedure: ACD-A/blood ratio 1:10; Interface position 6:2; blood flow rate always exceeding 65 mL/min; rpm 1750; cell collection from 4 to 7 mL/min; volume of blood processed 3.6 L followed by the rinsing of the system with 200 ml of saline; extraction of the content of the secondary separation chamber by the action of the plasma pump working at 20 mL/min for 2 min. With this procedure the platelet yield in 34 collections exceeded 3.1 x 10(11) and averaged 4.06 x 10(11). The procedure time was reduced to 56.5 minutes with a mean blood flow rate of 62.3 mL/min. The leukocyte and erythrocyte contamination of the products were in the range of 1 x 10(7) and 1 x 10(8) respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Evaluation Studies as Topic↗

[Report on surgical strategy in reoperation of esophageal achalasia].

Surgical therapy for achalasia of the esophagus gives good results in only 80-90% of cases. Several reasons could be responsible for this 10-20% failure; the most frequent causes are inadequate cardiomyotomy and reflux esophagitis. We report our experience and our procedure in the management of recurrent achalasia. The most important controversies are also discussed.

Esophageal Achalasia↗

Biochemical and clinical evaluation of a new cellulose diacetate secondary filter for cascade filtration.

We have performed 24 cascade filtration treatments in 8 patients with hyperviscosity syndrome (2 cases), essential mixed cryoglobulinemia, post-hepatitic cryoglobulinemia, Sjogrens disease, rheumatoid vasculitis, Miller-Fisher syndrome and chronic dysimmune polyneuropathy. New cellulose diacetate filters were employed, giving a satisfactory performance. At 1.5 L plasma treatment, the rejection rate for macromolecular plasma components was close to 90%, whereas albumin recovery was close to 70%. Treatments were clinically effective, confirming that cascade filtration is an alternative to conventional plasma exchange in patients with IgM or immune complex mediated diseases.

Blood Viscosity↗

Efficacy of discontinuous flow centrifugation compared with cascade filtration in Waldenstrom's macroglobulinemia: a pilot study.

In the treatment of Waldenstrom's macroglobulinemia (WM) and lipoprotein or immune complex mediated diseases, centrifugal and membrane plasma separation systems have been successfully employed over the past years. More recently, semiselective double filtration systems have been used in isolated cases. While it is hoped that cascade filtration (CF) will soon become a routine technique, a note of caution came from some investigators because of the lack of any evidence that CF does really deplete patients' plasma of known pathogenic macromolecules. The aim of this study was to test the efficacy of CF in the removal of IgM paraproteins in comparison with discontinuous flow centrifugation (DFC). Eight patients were treated by DFC and seven by CF; there were no significant differences between the two groups in terms of sex, age, clinical severity and IgM plasma concentration. After DFC or CF sessions, IgM concentration diminished by 50% and plasma viscosity by 60%, producing a comparable mean reduction in patients' clinical severity. Our in vivo results thus preliminarily answer the question whether CF is capable of removing known pathogenic macromolecules from patients' plasma, and the technique appears to warrant further investigations.

Centrifugation↗

A critical approach to therapeutic apheresis in the management of inflammatory dysimmune polyneuropathies.

Data concerning 37 patients with inflammatory dysimmune polyneuropathy treated by discontinuous flow centrifugation, membrane plasma separation and cascade filtration are presented. Plasmapheresis was combined with immunosuppressants in patients with chronic or relapsing neuropathy (8 patients), cryoglobulinemic (6 patients) and paraneoplastic disease (2 patients), whereas 21 patients with acute Guillain-Barré syndrome (GBS) underwent exclusively plasmapheresis. Most patients were treated during the onset or progression of their disease and excellent or satisfactory clinical results were obtained in 18 patients with GBS, 6 with cryoglobulinemia, 2 with paraneoplastic disease and 4 with chronic relapsing polyneuropathy. Prior to therapy, 34 patients had high levels of immune complexes (CIC); this level was clearly reduced by plasmapheresis and clinical results correlated well with this removal. 3 patients with chronic dysimmune polyneuropathy, without any evidence of CIC, were completely unaffected by treatment. The possible role of CIC in demyelinating polyneuropathies is discussed on the basis of information given by cascade filtration treatment of 7 patients.

Chronic Disease↗

Plasmapheresis combined with lymphocytapheresis and cytotoxic drugs as a therapeutic modality in neuroimmunological diseases.

Rebound after plasmapheresis is thought to be due to enhanced antibody and/or immune complex production. To prevent rebound a combination of steroids and immunosuppressive drugs has been used: lymphocytapheresis was employed in most patients, for not more than 10 sessions. 50 patients with myasthenia gravis, inflammatory myopathy, chronic dysimmune polyneuropathy and immune complex polyneuropathy have been treated and long-lasting benefits obtained in 35 patients. Rebound effects were observed only when cytotoxic drugs were not given or discontinued too soon. 8 patients who had been treated by plasmapheresis combined with steroids alone, after some recurrences of their disease, were switched to cytotoxic drugs, steroids and lymphocytapheresis combined with plasma exchange: in this group 7 patients eventually gained long lasting remissions. Our clinical experience strongly supports the hypothesis of a synergy between plasmapheresis and immuno-suppressive measures.

Autoimmune Diseases↗