The effect of Nitromint sublingual tablet and Nitromint aerosol (EGIS) has been studied in ambulance practice. Both drug forms relieved or controlled the complaints and symptoms, and proved to be effective in a great number of cases. Due to it's easier storage and easier applicability the aerosol is more advantageous than the sublingual tablet. Occasionally the simultaneous use of the two products is also beneficial. Supposedly the indication field of nitroglycerin will be extended in the near future and Nitromint preparations will be used in oxyology also for controlling other clinical conditions in which smooth muscle spasm has a major role.

Administration, Sublingual

A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, and temperature, right atrial pressure, right ventricular pressure, and dP/dt.

A new multisensor pacing device using respiratory rate (RR), stroke volume (SV), oxygen saturation (SO2), temperature (T), right atrial pressure (RAP), right ventricular pressure (RVP) and right ventricular dP/dt, has been developed. It consists of a 7F multisensor catheter and an external pacing unit. It allows simultaneous recording of the input signals and the corresponding data can be compared among the different parameters under identical conditions. Furthermore, several parameters can be combined in such a way as to form a new combination better suitable for rate responsive pacing. The response of each parameter to exercise was studied in 12 healthy volunteers (mean age: 28 years). Exercise testing was carried out using a bicycle ergometer, with workloads up to 200 W. The dynamic characteristics, response and sensitivity to changes of workloads of each parameter were analyzed and compared to one another. SO2 proved to be a quick responding parameter (less than 10 sec) with higher sensitivity in the low exercise range (less than 75 W), T, on the other hand, responded slowly (greater than 30 sec) to exercise changes and had the highest sensitivity in the exercise range beyond 75 W. RR displayed a slow response (greater than 30 sec) and an adequate sensitivity was only found in the upper exercise range (greater than 100 W). SV reacted rapidly to workload changes (less than 10 sec) but showed poor sensitivity at all exercise levels. RAP, RVP and dP/dt displayed quick responses and constantly good sensitivity throughout the workload range. Furthermore, respiratory rate was easily derived from the RAP curve. Special algorithms were developed for each parameter so that pacing rate would reproduce sinus rate behavior. We found that SO2 and all pressure parameter imitated sinus rate response quite well. When using parameter combinations, SO2 and T proved to be superior. Five patients (mean age 68 years) with third degree AV-block were stimulated temporarily using this system. Compared to fixed rate stimulation (VVI 70), exercise performance improved, using SO2 as the input parameter for rate response, by 25% to 50%.

Adult

[Stroke volume, central venous oxygen saturation and blood temperature as control parameters of frequency-adapted pacemaker stimulation].

In order to compare various physiological parameters under identical conditions and to evaluate the "optimal" combination of parameters for triggering a pacing system, a multisensor-catheter of 7 F size was developed. By this catheter placed in the right ventricular cavity, sinus rate (SR), mixed venous oxygen saturation (SO2), temperature (T) and stroke volume (SV) were continuously recorded in 7 volunteers. SR, T, SO2 and SV were analysed for their steady state relationships to workload (P) and for their dynamic characteristics during standardized exercise tests. During exercise the delay times of SR, SO2 and SV were less than 10 sec., whereas that of T was markedly longer ranging from 70 sec. at low exercise levels to 30 sec. at high levels (200 Watts). During recovery delay times of SR, SO2 and SV ranged from 5 to 10 sec., that of T ranged from 20 to 30 sec. The relationship of SR to the workload (0-200 W) performed was linear (r = 0.98), that of T was linear above 50 Watts (r = 0.92), that of SO2 followed an exponential function (r = 0.89). Initial changes of SV were independent (r = 0.02) of the extent of workload. The sensitivity (S = dV/dP) was calculated from the relationship of the parameters (V) measured to the level of exercise performed. SO2 was highly sensitive at the lower range of exercise (less than 75 W), T became constantly sensitive above 50 W, below 50 W the sensitivity of T was continuously decreasing. SR was constantly sensitive over the whole range of exercise (0-200 W), the initial change of SV was not sensitive to the extent of workload.

Adult

Rate control with an external SO2 closed loop system.

In 20 volunteers (mean age 35.5 y) and 12 pacemaker patients (mean age 68.7 y), central venous oxygen saturation (SO2) was monitored continuously by means of an optical sensor integrated in an external transvenous pacing lead placed in the right ventricular cavity. From the SO2 signal recorded at rest and during various modalities of exercise, an algorithm for controlling pacing rate of an external pacing system was developed. An open loop system was used in the volunteers, allowing the comparison of the computed pacing rate with the individual intrinsic heart rate. There was an excellent correlation between the two frequencies as far as the dynamic characteristics and the steady state relationship were concerned. In five pacemaker patients who were stimulated via the external lead, a closed loop control of pacing rate was used. In one patient with a DDD pacemaker implanted for third degree AV-block, the rate response of the SO2 driven pacemaker was well in accordance with the rate attained with the implanted atrial triggered system. With both pacing modes, exercise capacity as determined on a symptom limited treadmill test was identical. In four patients (3 AV block III, 1 bradyarrhythmia) an improvement in exercise tolerance up to 65 percent could be demonstrated with the rate responsive pacing mode. In all patients, it could be shown that an autoregulating pacemaker system with SO2 is an open possibility.

Adult