PubMed Health⌕ Search

Biomedical subjects

G Gennaro

Publications and source records attributed to G Gennaro.

12 recordsLinked to original sources

ESR response to gamma-rays of alanine pellets containing B(OH)3 or Gd2O3.

ESR response to gamma-irradiation (1-50 Gy) of blends containing alanine and either B(OH)(3) or Gd(2)O(3) is reported. The sensitivity of the alanine--B(OH)(3) blend is comparable to the sensitivity of pure alanine, although its lowest detectable dose, LDD, is smaller ( approximately 1.3 Gy) than that of pure alanine ( approximately 2.9 Gy). Alanine with Gd(2)O(3) is about two times more sensitive than pure alanine, and its LDD is 0.8 Gy. The better sensitivity and LDD are probably due to the high atomic number (Z=64) of gadolinium, which enhances the interaction probability with photons and, consequently, the radical yield. This study suggests that other high-Z atoms may be useful for increasing the sensitivity of the response of alanine to gamma-radiation.

Alanine↗

Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography.

Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml(-1) and 1.34 mg ml(-1) for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml(-1) and 1.31 mg ml(-1). With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml(-1) (8 mm diameter) and 5.75 mg ml(-1) (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml(-1) (8 mm diameter) and 1.57 mg ml(-1) (5 mm diameter).

Algorithms↗

Dual-energy imaging in full-field digital mammography: a phantom study.

A dual-energy technique which employs the basis decomposition method is being investigated for application to digital mammography. A three-component phantom, made up of plexiglas, polyethylene, and water, was doubly exposed with the full-field digital mammography system manufactured by General Electric. The 'low' and 'high' energy images were recorded with a Mo/Mo anode-filter combination and a Rh/Rh combination, respectively. The total dose was kept within the acceptable levels of conventional mammography. The first hybrid images obtained with the dual-energy algorithm are presented in comparison with a conventional radiograph of the phantom. Image-quality characteristics at contrast cancellation angles between plexiglas and water are discussed. Preliminary results show that a combination of a standard Mo-anode 28 kV radiograph with a Rh-anode 49 kV radiograph provides the best compromise between image-quality and dose in the hybrid image.

Algorithms↗

Stopped-flow kinetic studies of low potential electron carriers of the photosynthetic bacterium, Rhodobacter capsulatus: ferredoxin I and NifF.

The kinetics of electron-transfer reactions involving nif-specific proteins from Rhodobacter capsulatus; ferredoxin I, NifF, Fe-protein of nitrogenase and dithionite were studied using stopped-flow spectrophotometry. Kinetic evidence was obtained for the formation of a tight (0.44 microM) complex between NifF and Fe-protein. Under the same conditions, FdI interacted only weakly (Kd > 325 microM) with Fe-protein. There was no evidence for complex formation between NifF and FdI since the reaction NifFSQ + FdIred had a bimolecular rate constant of 12.5 +/- 1.2 x 10(3) M-1 s-1. These results suggest that NifF, which is present in only small quantities in the cell, can make a significant contribution to the overall rate of nitrogen fixation due its high reactivity with Fe-protein. Moreover, the apparent lack of specific interaction between NifF and FdI suggest that they act in vivo in parallel to reduce Fe-protein and not in series.

Dithionite↗

Cloning, characterization, and regulation of nifF from Rhodobacter capsulatus.

The Rhodobacter capsulatus nifF gene and upstream sequence were cloned by using a probe based on the N-terminal sequence of NifF. nifF was found to not be contained in the previously described nif regions I, II, and III. Comparison of the deduced amino acid sequence showed that it is highly similar to NifF from Azotobacter vinelandii and NifF from Klebsiella pneumoniae. Analysis of translational fusions demonstrated that the regulation of transcription was the same as previously reported at the protein level. Insertional mutagen esis showed that NifF contributes significantly to nitrogenase activity under normal nitrogen-fixing conditions and that it is absolutely required for nitrogen fixation under iron limitation.

Amino Acid Sequence↗

[Quality control of mammography: potential use of a new device for testing the image quality and the dose].

The authors tested a new equipment containing a phantom to check quality mammographic image and an electronic instrument to measure incident radiation (Phan-EX). The phantom contains objects which have similar characteristics to the details of diagnostic interest and allows an easy and accurate estimation of image quality on the basis of the number of objects detected. The radiation detector, consisting of a solid state photodiode, provides an integer proportional to the input exposure. The results obtained highlighted a good reproducibility of instrument output and a good relationship between these values and the exposure ones obtained with a much more expensive ionization chamber. The device response was linear in varying both the anodic exposure (mAs) and the x-ray tube voltage (varying the energy, the calibration factor varied only by a small percent). The authors conclude that the Phan-EX may be useful for quality assurance of the mammographic unit. Furthermore, they suggest some of its practical applications: daily tests of qualitative of the mammographic unit and the treatment system performance, control of the automatic exposure probe, choice and optimization of exposure and treatment of the film parameters, the determination of the output of the x-ray tube, the evaluation of the sensitivity of different screen/film systems.

Equipment Design↗

Purification and properties of a nif-specific flavodoxin from the photosynthetic bacterium Rhodobacter capsulatus.

A flavodoxin was isolated from iron-sufficient, nitrogen-limited cultures of the photosynthetic bacterium Rhodobacter capsulatus. Its molecular properties, molecular weight, UV-visible absorption spectrum, and amino acid composition suggest that it is similar to the nif-specific flavodoxin, NifF, of Klebsiella pneumoniae. The results of immunoblotting showed that R. capsulatus flavodoxin is nif specific, since it is absent from ammonia-replete cultures and is not synthesized by the mutant strain J61, which lacks a nif-specific regulator (NifR1). Growth of cultures under iron-deficient conditions causes a small amount of flavodoxin to be synthesized under ammonia-replete conditions and increases its synthesis under N2-fixing conditions, suggesting that its synthesis is under a dual system of control with respect to iron and fixed nitrogen availability. Here we show that flavodoxin, when supplemented with catalytic amounts of methyl viologen, is capable of efficiently reducing nitrogenase in an illuminated chloroplast system. Thus, this nif-specific flavodoxin is a potential in vivo electron carrier to nitrogenase; however, its role in the nitrogen fixation process remains to be established.

Amino Acids↗

Changes of lipocalin type prostaglandin D-synthase in the seminal plasma of subfertile man.

It was proposed that lipocalin type prostaglandin D synthase (L-PGD-S), a bifunctional protein both synthesizing PGD2 and transporting retinoids and other lipophilic ligands, could be involved in the development and the maturation of sperm. In the present study, the seminal plasma (SP) of 59 adult males was analyzed by standard WHO methods and immunoblotting, using a monospecific polyclonal antibody directed against L-PGD-S. Briefly, aliquots of SP (2.5 microl), were fractionated by polyacrylamide electrophoresis in the presence of sodium dodecyl sulfate, the blots were stained and densitometrically analyzed. To obtain quantitative data, the aliquot of SP was selected within the linear part of the dose/band intensity curve and a proper quality control was analyzed in all blots to normalize the intensity of the bands of different experiments. A significant reduction (p<0.05) of the L-PGD-S levels was observed in severe oligozoospermic patients compared to normozoospermic subjects and a significant correlation between L-PGD-S levels and sperm concentration was found, as reported by other authors. Further studies are warranted to evaluate the possible diagnostic and pharmacological applications of these observations.

Electrophoresis, Polyacrylamide Gel↗