PubMed Health⌕ Search

Biomedical subjects

G Giaveri

Publications and source records attributed to G Giaveri.

4 recordsLinked to original sources

Determination of baseline element composition of lichens using samples from high elevations.

The results of a survey aimed at providing baseline element composition of lichens from unpolluted or very low polluted areas are reported. Lichen samples collected at high elevation areas in Himalayas (Nepal), Mt. Kenya (Kenya) and the Alps (Italy) were analyzed for their trace element content, mostly by INAA, allowing for a multi-element analysis. The elemental composition of lichen samples was essentially influenced by natural occurrence, mainly airborne soil dust. However, also anthropogenic input determined by long-distance atmospheric transport of pollutants was involved for some highly volatile elements such as Br, Cd and Sb. To avoid the influence of soil contamination and air pollution, and obtain baseline concentrations to be used as reference (the "natural" elemental composition of lichens), the average of the lowest concentrations is suggested.

Air Pollutants↗

Preconcentration and preseparation procedure for platinum determination at trace levels by neutron activation analysis.

A procedure that simultaneously allows both preconcentration and preseparation of platinum for its determination by neutron activation analysis at trace levels (<0.1 microg x g(-1)) in environmental related matrixes is developed. The method is mainly based on a two-step chemical procedure: (i) a preirradiation concentration/separation based on a column chromatography separation where the platinum is previously retained and subsequently separated from Au, Ca, Na, Br, and P; (ii) a postirradiation separation/purification of the 199Au at 158.4 keV used for the platinum determination via [198Pt (n,gamma)-->199Pt (beta-)-->199Au]. The method eliminates the following radionuclides with the gamma lines in the region of 158 keV: 47Sc (daughter of Ca) at 159.3 keV; 199Au (produced by double neutron capture onto the natural 197Au) at 158.4 keV; 123m Te at 158.8 keV. In addition, the background activity deriving from 24Na, 32p, and 82Br is drastically reduced. The method was tested by the analysis of certified rock material and then applied for platinum determination in airborne particulate matter.

Journal Article↗

Some analytical problems encountered for trace elements determination in the airborne particulate matter of urban and rural areas.

The determination of trace elements (TE) in airborne particulate matter collected onto filters requires an accurate evaluation of the entire analytical procedure. Since many elements have to be determined at a few milligrams of air dust at nanogram levels, possible sources of error can arise from uncontrolled parameters such as blank of the filters, sample homogeneity, pre-analytical treatment, primary and comparator standards. These potential critical points are presented here and discussed on the basis of the experience developed in our laboratory in previous studies where several TE monitoring campaigns have been performed for air particulate matter collected in urban as well as in rural residential areas of north Italy. Instrumental neutron activation analysis (INAA) and electrothermal atomic absorption spectroscopy (ET-AAS) have been used for the investigation of more than 30 trace elements.

Air Pollution↗

Trace elements total content and particle sizes distribution in the air particulate matter of a rural-residential area in north Italy investigated by instrumental neutron activation analysis.

The concentrations (ng/m3) of more than 30 trace elements have been determined in the total air particulate of a rural-residential area in north Italy. By collecting the aerosols with multistage impactors the distribution of the trace elements in the different size-fractionated particles has been also investigated. The fine 'inhalable' fraction with particles of less than 10 microns in equivalent aerodynamic diameter (PM10) as well as the subsequent finest 'respirable' fractions with particles of 0-1.1 microns (alveolar), 1.1-4.6 microns (bronchial) and 4.6-9 microns (tracheo-pharynx) have been analyzed and evaluated. Apart from Pb, Cd and, in some cases, Ni and Cu which have been determined by ETAAS (electrothermal atomic absorption spectroscopy), all measurements have been carried out by instrumental neutron activation analysis (INAA).

Air Pollutants↗