Magnetization transfer time-of-flight magnetic resonance angiography.

Time-of-flight (TOF) angiography based on inflow enhancement is limited by the steady-state signal differences between blood and the surrounding stationary tissues. We present a new TOF sequence in which magnetization transfer contrast is used to supplement wash-in effects. Angiograms demonstrating the superior performance of this technique are presented.

Blood Vessels

Projection reconstruction techniques for reduction of motion effects in MRI.

Projection reconstruction (PR) techniques are shown to have intrinsic advantages over spin-warp (2DFT) methods with respect to diminished artifacts from respiratory motion. The benefits result from (1) portrayal of artifacts as radial streaks, with the amplitude smallest near the moving elements; (2) streak deployment perpendicular to the direction of motion of moving elements and often residing outside the anatomic boundaries of the subject; (3) inherent signal averaging of low spatial frequencies from oversampling of central k-space data. In addition, respiratory-ordered view angle (ROVA) acquisition is found to diminish residual streaking significantly by reducing interview inconsistencies. Comparisons of 2DFT and PR acquisitions are made with and without ROVA. Reconstructions from magnitude-only projections are found to have increased streaks from motion-induced phase shifts.

Abdomen

MR imaging of lung parenchyma: a solution to susceptibility.

The authors have developed a pulse sequence for imaging lung parenchyma with projection reconstruction magnetic resonance (MR) imaging that reduces the effects of motion and susceptibility. In this study, the projection reconstruction technique was further modified by optimizing MR signal frequencies for reconstructing the images. This was done by means of one of two methods. With the first method, a susceptibility map was derived from the raw image data and this map was used to indicate the optimal frequencies for reconstructing the images. The second method of susceptibility correction was a postprocessing technique in which the optimal reconstruction frequencies were selected with use of specific focusing criteria to generate the least blurred image. The effect of using susceptibility map correction on a phantom was demonstrated, and both of these methods were used to improve the visibility of pulmonary structures on images of subjects with normal and abnormal lungs.

Humans

The pelvis: T2-weighted fast spin-echo MR imaging.

Fast spin-echo (SE) T2-weighted magnetic resonance (MR) imaging provides images with highly T2-weighted contrast in substantially reduced imaging times. In a prospective evaluation, fast SE T2-weighted imaging of the pelvis was compared with conventional SE T2-weighted imaging in 30 consecutive patients in whom pelvic pathologic conditions were suspected. Three reviewers independently analyzed the images for (a) overall image quality, (b) pelvic organ definition, (c) conspicuity of pelvic fluid, and (d) conspicuity of pelvic pathologic conditions. Fast SE images were rated superior to conventional SE T2-weighted images in 60% (54 of 90) of the case reviews for overall image quality, in 69% (62 of 90) for pelvic organ definition, in 63% (57 of 90) for conspicuity of pelvic fluid, and in 68% (43 of 63) for conspicuity of pelvic pathologic conditions. The fast SE examinations were typically three to four times faster than conventional SE T2-weighted examinations. No pathologic findings seen on conventional SE T2-weighted images were undetected on fast SE images. Fast SE images may replace conventional SE T2-weighted images in MR imaging of the pelvis.

Abdomen

Intracerebral lesion contrast with spin-echo and fast spin-echo pulse sequences.

Fast spin-echo (FSE) magnetic resonance (MR) imaging was compared with conventional, peripherally gated T2-weighted spin-echo (SE) imaging in the detection of high- and low-signal-intensity lesions in the central nervous system. Lesion detectability was determined with percentage of contrast measurements and contrast-to-noise ratios with two different measurements for noise. All three measures of lesion detectability were similar. FSE and SE sequences were quantitatively equivalent in the detection of high-signal-intensity lesions. The SE sequence, however, was superior to the FSE sequence in the detection of small, low-signal-intensity lesions in the central nervous system caused by magnetic susceptibility effects.

Adolescent

Arterial and venous blood flow: noninvasive quantitation with MR imaging.

Quantitative measurements of arterial and venous blood flow were obtained with phase-contrast cine magnetic resonance (MR) imaging and compared with such measurements obtained by means of implanted ultrasound (US) blood flow probes in anesthetized dogs. The US flowmeter was enabled during a portion of each MR imaging sequence to allow virtually simultaneous data acquisition with the two techniques. MR imaging data were gated by means of electrocardiography and divided into 16 phases per cardiac cycle. The rates of portal venous blood flow measured with MR imaging and averaged across the cardiac cycle (710 mL/min +/- 230 [standard deviation]) correlated well with those measured with the flowmeter and averaged in like fashion (751 mL/min +/- 238) (r = .995, slope = 1.053). The correspondence in arterial blood flow was almost as good. No statistically significant difference existed between the paired measurements of blood flow obtained with MR imaging and the implanted probe. It is concluded that, as a noninvasive means of accurate quantification of blood flow, phase-contrast MR imaging may be especially useful in deep blood vessels in humans.

Animals

Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction.

An enhancement to Dixon's technique is described which can provide error-free decomposition of water and fat proton images even in the presence of off-resonance conditions which result from susceptibility differences, demagnetization, or shim errors. The method uses three measurements with phase shifts of 0, pi, and -pi between the fat and water resonances. The additional information provided by the third measurement is used to calculate an image of the field inhomogeneity in addition to true water and fat images. The signal-to-noise ratio (SNR) in the decomposed images is equivalent to that of a 2.7 NEX acquisition (instead of 3 NEX), yielding an SNR imaging efficiency of 95%. In addition, the B0 image which is provided may have diagnostic value in its own right. Examples of head and body scans often portray surprisingly large B0 shifts near interfaces between air or bone and soft tissue.

Algorithms

Prostatic MR imaging performed with the three-point Dixon technique. Work in progress.

The three-point Dixon technique is an enhancement of the original Dixon method for the creation of water- and fat-proton magnetic resonance (MR) images. With the three-point Dixon technique, three measurements of phase shift at 0, pi, and -pi between the fat and water resonances are employed. Compensation for B0 inhomogeneity leads to an error-free decomposition into water- and fat-proton images; an accurate B0 map is also created. The lack of chemical shift artifact in the water- and fat-selective MR images permits the application of narrow receive bandwidth for the creation of T2-weighted images with a high signal-to-noise ratio. The technique was applied in vivo with four healthy subjects, seven patients with prostatic carcinoma, and one patient with benign prostatic hypertrophy and compared with conventional T2-weighted imaging. The three-point technique yielded images with improved definition of normal intraprostatic structures and zonal anatomy and, in some cases of prostatic carcinoma, provided better visualization of extraprostatic spread of tumor.

Adult

Lung parenchyma: magnetic susceptibility in MR imaging.

Magnetic susceptibility effects in magnetic resonance (MR) imaging of normal lung parenchyma occur because of magnetic-field inhomogeneities induced by the microscopic heterogeneity of the lung. The effects on MR imaging of the lung are loss of signal from intravoxel phase dispersion (measured with T2') and a shift in the macroscopic resonant frequency from that of water toward that of air (delta v). These effects of MR imaging at 1.5 T were quantitated by measuring T2' decay and delta v at different locations in the lungs of two adult volunteers and one excised inflated human lung. The average T2' was 7 msec in the excised inflated specimen and 6.3 msec in normal in vivo lungs. There was a gravitational increase in T2' from nondependent to dependent lung. T2' increased to 35 msec in atelectatic lung tissue and to more than 140 msec in tumor. The macroscopic resonant lung frequency increased to 3.6 ppm more than that of mediastinal muscle. These values are important for developing MR pulse sequences appropriate for imaging lung parenchyma.

Humans

Rapid calculation of T1 using variable flip angle gradient refocused imaging.

We present a method for rapid measurement of T1 relaxation times using gradient refocused images at limited flip angles and short repetition times. This "variable nutation" techniques was investigated using a T1 phantom. There was a high correlation between measurements obtained with the variable nutation and partial saturation techniques. The ability of this method to create calculated T1 images is also demonstrated. We conclude that the variable nutation method may allow measurement of T1 relaxation times with a significant reduction in acquisition time compared to partial saturation techniques.

Humans

The intrinsic signal-to-noise ratio in NMR imaging.

The fundamental limit for NMR imaging is set by an intrinsic signal-to-noise ratio (SNR) for a particular combination of rf antenna and imaging subjects. The intrinsic SNR is the signal from a small volume of material in the sample competing with electrical noise from thermally generated, random noise currents in the sample. The intrinsic SNR has been measured for a number of antenna-body section combinations at several different values of the static magnetic field and is proportional to B0. We have applied the intrinsic and system SNR to predict image SNR and have found satisfactory agreement with measurements on images. The relationship between SNR and pixel size is quite different in NMR than it is with imaging modalities using ionizing radiation, and indicates that the initial choice of pixel size is crucial in NMR. The analog of "contrast-detail-dose" plots for ionizing radiation imaging modalities is the "contrast-detail-time" plot in NMR, which should prove useful in choosing a suitable pixel array to visualize a particular anatomical detail for a given NMR receiving antenna.

Abdomen

Methodology of in vivo human sodium MR imaging at 1.5 T.

The methodology of sodium-23 (Na-23) imaging is reported in relationship to the physiological factors that determine the chemical environment of the Na-23 nucleus. Contrast resolution is given as a function of imaging time and spatial resolution. Data showing the optimal relaxation time for sodium imaging are given, and the linear quantitative relationship between sodium concentration and voxel intensity for our imaging system is confirmed. The major problem facing in vivo sodium imaging is the ability to differentiate intracellular sodium from extracellular sodium. The sodium in blood serum (extracellular) and packed red blood cells (intracellular) both exhibit biexponential T2 decay. These results indicate that T2 measurements alone will be insufficient for discriminating extracellular from intracellular sodium. Instead, other methods based on the underlying physiological properties of in vivo sodium imaging, such as the diffusion coefficient, will be necessary to truly separate extracellular from intracellular sodium.

Brain Neoplasms

Theoretical resolution of computed tomography systems.

A simple analytic model is presented which is used to calculate the impulse response of a computed tomography system for parametric variations of the geometry. The model is useful for fan beam as well as parallel beam geometries. Results show that wide-aperture detector systems have intrinsic resolution limitations that are not mitigated by oversampling. Furthermore, the optimum focal spot size of the X-ray source is found to be dependent on the detector geometry.

Mathematics

Encoding strategies for three-direction phase-contrast MR imaging of flow.

Three encoding strategies for the measurement of flow velocities in arbitrary directions with phase-contrast magnetic resonance imaging are presented; their noise and dynamic range performance are compared by means of theoretical analysis and computer simulation. A six-point measurement strategy is shown to be quite inefficient in terms of velocity variance per unit time. A simple four-point method exhibits equal dynamic range; its noise depends on flow direction but on average is equal to that of the six-point method. An alternate, balanced four-point method has noise that is direction independent and has, depending on implementation, possibly lower noise levels. Either four-point method is more efficient and is preferred over the six-point approach.

Blood Flow Velocity

Phase-offset multiplanar (POMP) volume imaging: a new technique.

Phase-offset multiplanar (POMP) imaging is a technique that excites several sections simultaneously for improved imaging efficiency. The centers of the reconstructed images from each of the POMP sections are offset from each other in the phase-encoding direction by means of view-dependent phase modulation of the radio-frequency (RF) excitation pulses and are placed adjacent to each other in the reconstruction. With a suitable reconstruction matrix size, the images can be made nonoverlapping and stored separately. At constant imaging time, signal-to-noise ratio (S/N), and resolution, POMP imaging produces a factor NP more sections than a conventional sequence but with a reduced field of view. Alternatively, imaging time may be increased by the factor NP to retain the same field of view but with the expected S/N advantage. The average RF power deposited by the 90 degrees composite RF pulse is greater by the factor Np, but the power for the 180 degrees pulse is unchanged. The POMP method is discussed and compared with three-dimensional and Hadamard techniques.

Humans