PubMed Health⌕ Search

Biomedical subjects

G H Thorpe

Publications and source records attributed to G H Thorpe.

At least 19 recordsLinked to original sources

The impact of therapeutic doses of paracetamol on serum total antioxidant capacity.

INTRODUCTION: A link between regular paracetamol intake and asthma in adults has recently been postulated. Detoxification of paracetamol may deplete stores of glutathione, which is one of the major antioxidants present in the lung. A reduced source of glutathione in the lung may lead to increased oxidative damage to the epithelium and hence increased frequency and severity of asthma attacks in susceptible individuals. AIM OF STUDY: This study aimed to determine whether regular intake of maximum therapeutic doses of paracetamol reduced serum antioxidant capacity in healthy volunteers. METHODS: Fifteen young healthy volunteers (nine men, six women, mean age 21.3 years, range 19-32) took maximum therapeutic doses of paracetamol (1 g four times a day) for 14 days. On days 0 and 14 blood samples were taken at baseline and hourly for a period of 4 h following ingestion of 1 g paracetamol. Single venous blood samples were collected 1 h after ingestion of 1 g paracetamol on days 4, 7 and 10. Blood samples were analysed for serum paracetamol concentration and total antioxidant capacity. RESULTS: Mean total antioxidant capacity was significantly reduced over the 3-h post-dosing on both days 0 and 14 (P < 0.01). The results from days 4, 7 and 10 showed a trend towards reduced antioxidant activity over time. On day 14 values were consistently lower compared with the corresponding times on day 0 (P < 0.01 at 0, 1, 3 and 4 h, P < 0.05 at 2 h). CONCLUSIONS: Chronic ingestion of maximum therapeutic doses of paracetamol depletes serum antioxidant capacity in healthy volunteers in as few as 14 days, possibly by a reduction in glutathione. This may have implications for analgesic use in asthmatic individuals. Further studies are now required to assess the impact of paracetamol on antioxidant defences in the lung.

Acetaminophen↗

Systematic review of near patient test evaluations in primary care.

OBJECTIVE: To identify and qualitatively synthesise the findings from all studies that have examined the performance and effect of near patient tests in the primary care setting. DESIGN: Systematic review of published and unpublished research 1986-99. MAIN OUTCOME MEASURES: Test performance characteristics, measures of effect on clinical practice or patient outcome. RESULTS: 101 relevant publications were identified. The general quality of these papers was low, and consequently only 32 papers were assessed in detail. Although these papers gave some indication of the value of near patient testing in areas such as anticoagulation monitoring and group A beta haemolytic streptococcus testing, the research raised many more questions than it answered. Almost no reports were found of unbiased assessment of the effect of near patient tests in primary care on patient outcomes, organisational outcomes, or cost. CONCLUSIONS: Available research provides little evidence to guide the expansion of use of near patient testing in primary care. Further research is needed in areas of clinical practice where near patient tests might be most beneficial.

Humans↗

Blood lancing systems for skin puncture.

Blood tests increasingly require only a few microlitres of blood. Lancing systems used for the collection of blood have the potential to transmit infection if used improperly. These systems vary in the amount of blood and pain produced.

Blood Specimen Collection↗

Selecting blood glucose monitoring systems.

A wide range of blood glucose monitoring systems is available for use in different applications. The systems have varying characteristics which should be taken into consideration during selection. Operator technique can influence the quality of the results.

Bias↗

Blood glucose measuring systems.

Glucose monitoring and lancing systems have proved useful in a range of patient testing applications in hospitals, general practice and for use by patients at home. Products are becoming easier to use and less technique dependent. It is important to be aware of their specific characteristics and to adhere to manufacturers' and local hospital laboratory guidelines.

Blood Glucose Self-Monitoring↗

Antioxidant status in patients with uncomplicated insulin-dependent and non-insulin-dependent diabetes mellitus.

Oxidative damage by free radicals has been implicated in the pathogenesis of vascular disease in diabetes. We compared the radical-scavenging antioxidant activity of serum from 28 patients with insulin-dependent diabetes mellitus and 24 patients with non-insulin-dependent diabetes mellitus uncomplicated by vascular disease with age-matched non-diabetic control subjects. Patients with insulin-dependent diabetes had significantly reduced total antioxidant activity (320.2 +/- 11.3 vs. 427.5 +/- 19.2 mumol L-1; P < 0.001). This was attributable to lower urate (209.4 +/- 10.4 vs. 297.1 +/- 16.7 mumol L-1; P < 0.001) and vitamin C levels (63.6 +/- 6.0 vs. 87.5 +/- 4.9 mumol L-1; P < 0.01). Patients with non-insulin-dependent diabetes had lower total antioxidant activity than age-matched control subjects (433.8 +/- 25.4 vs. 473.9 +/- 30.2 mumol L-1; NS), reflecting lower urate (299.5 +/- 19.4 vs. 324.8 +/- 21.4 mumol L-1; NS) and vitamin C levels (38.6 +/- 5.7 vs. 58.5 +/- 5.3 mumol L-1; P < 0.05). Multiple regression analysis showed that urate, vitamin C and vitamin E were the major contributors to serum total antioxidant activity. These results show that diabetic patients have significant defects of antioxidant protection, which may increase vulnerability to oxidative damage and the development of diabetic complications.

Adult↗

Enhanced chemiluminescent assay for measuring the total antioxidant capacity of serum, saliva and crevicular fluid.

This paper reports the development of an enhanced chemiluminescent (ECL) assay for measuring the total antioxidant (AO) capacity of serum, saliva and a fluid collectable from the gum margin called gingival crevicular fluid (GCF). The theory behind the assay is explained, and the optimum conditions for the assay, and for storage of reagents and clinical samples is described. Calibration lines were linear (R > or = 0.99; P < 0.0001) and the within batch coefficient of variations for a water soluble vitamin E analogue (Trolox), serum and saliva samples were < 5%. In saliva and GCF, a characteristic AO response not seen in serum of the same patients, was identified. Total peripheral (serum) and local (saliva) AO capacities (mumol/L Trolox) were investigated in patients with (n = 18) and without (n = 16) adult periodontitis. Serum AO status did not differ between groups. Salivary total AO concentrations were lower in the peridontitis (P) group [175 (53) mumol/L] than in the non-periodontitis (NP) group [254 (110) mumol/L1: P < 0.01], as were saliva:serum AO ratio's [0.37 (0.11) versus 0.5 (0.18): P < 0.01]. Periodontitis patients may have a reduced salivary AO concentration, which could result from, or predispose to, the damaging effects of reactive oxygen species (ROS). The potential for ROS production in the oral and periodontal environment may explain the presence of a specific antioxidant in oral fluids that is not detectable in serum. The ECL assay described provides a rapid, simple and reproducible method of measuring total antioxidant defence in small volumes of biological fluids.

Adult↗

Poor glycaemic control is associated with reduced serum free radical scavenging (antioxidant) activity in non-insulin-dependent diabetes mellitus.

The diabetic patient is at significantly increased risk of developing vascular disease. Its aetiology may involve oxidative damage by free radicals and protection against such damage can be offered by radical-scavenging antioxidants. We investigated whether there was a relationship between glycaemic control as assessed by measurement of glycated haemoglobin (HbA1c) and serum antioxidant status in a population of 118 diabetic outpatients with either insulin-dependent or non-insulin-dependent diabetes. Amongst patients with non-insulin-dependent diabetes mellitus there was a significant inverse correlation between levels of glycated haemoglobin and total free radical scavenging activity (r = -0.456, P < 0.0001). This association resulted primarily because of a similar correlation with uric acid (r = -0.421, P = 0.0003). There was also a weak inverse correlation with vitamin A but no significant association with vitamin C or vitamin E levels. There were no significant associations found amongst the patients with insulin-dependent diabetes. These results indicate that poor diabetic control is associated with reduced serum free radical scavenging (antioxidant) activity in non-insulin-dependent diabetes mellitus. By implication improved glycaemic control may preserve serum antioxidant status in diabetes.

Adult↗

An investigation of the antioxidant activity of black tea using enhanced chemiluminescence.

Antioxidants are important species which possess the ability to protect the body from damage caused by free radical-induced oxidative stress. A variety of free radical-scavenging antioxidants exist within the body many of which are derived from dietary sources. There is currently much interest in the antioxidant role of flavonoids and other polyphenols found in tea, wine, fruit and vegetables. Enhanced chemiluminescence is a simple technique which can be used as a rapid and sensitive assay for measuring the antioxidant activity of beverages such as green and black tea. This article examines the impact of water temperature, stewing time, leaf concentration and the addition of milk upon the antioxidant activity of black tea solutions. The antioxidant activity of a range of commercially available black and green teas has also been measured.

Animals↗

A review of near patient testing in primary care.

AIMS AND OBJECTIVES: The aim was to identify publications relating to near patient testing (NPT), the use of alternative delivery systems between laboratory and general practice, including electronic data interchange (EDI), and computerised diagnostic decision support (CDDS), in the primary care setting to answer the following questions. What is the availability of NPT for primary care? What evidence is available to support the clinical effectiveness of NPT? What evidence is available on the accuracy and reliability of NPT within primary care? What evidence is available on the cost-effectiveness of different NPTs? How may CDDS improve the effectiveness of NPT? What evidence is available that compares NPT and existing laboratory services? What evidence is available on the cost-effectiveness of EDI or alternative delivery systems? HOW THE RESEARCH WAS CONDUCTED: Eight databases were searched, and the bibliographies from relevant publications checked for completeness. Unpublished work and publications not included in the databases were obtained by personal contact with collaborators, and from a postal survey sent to heads of academic departments of general practice and clinical chemistry and to researchers active or interested in the field worldwide. Questionnaires were also sent to 150 commercial organisations. Publications that met agreed definitions and reported original data were included in the systematic review. Of the 1057 publications identified, 102 (92 related to NPT, eight to CDDS, and two to EDI) were passed to the reviewers for appraisal of validity. The limited amount of published research relating to any particular NPT prohibited meta-analysis. Scoring systems to assess the validity of evaluations were also difficult to apply. RESEARCH FINDINGS: A wide variety of NPT systems have been developed. In general, the quality of the methods reported in the literature was poor. The issue of patient convenience and acceptability has not been adequately addressed. No evaluations of alternative delivery systems met the review criteria. No studies have evaluated the telephone or fax machine as a means of reporting results. For EDI, the majority of papers were descriptive. EDI and alternative delivery systems are not a replacement for NPT when the provision of an immediate result might have an impact on the quality of care. EDI may have clinical and cost advantages over traditional means of communication, but this has not been evaluated. The advisory role of the laboratory can be supported by CDDS. The use of CDDS and NPT has not, however, been fully evaluated. Few economic analyses have been conducted, and most were simple cost analyses. There are insufficient data for conclusions to be drawn on the cost-effectiveness of NPT in primary care. RECOMMENDATIONS: FURTHER SYSTEMATIC REVIEWS: Subject-specific systematic reviews are required that include laboratory and secondary care studies, and consider the potential for altering current management and patient acceptability. Priority topics include: biochemistry profiles on desktop analysers; cholesterol testing; urinalysis for the diagnosis of urinary tract infection; anticoagulation control; NPTs for the identification of acute infection. (ABSTRACT TRUNCATED)

Cost-Benefit Analysis↗

Antioxidant depletion during aortic aneurysm repair.

Ischaemia-reperfusion injury generates oxygen-derived free radicals leading to local and distant damage. A simple method of following oxidative activity is to measure the consumption of endogenous scavenging antioxidants; an enhanced chemiluminescent assay was used to study this phenomenon in 21 patients undergoing surgery for abdominal aortic aneurysm (AAA). Samples of peripheral venous blood were taken before induction of anaesthesia and then from a central venous line and the inferior mesenteric vein before, during, and after clamping of the aorta. Further specimens were taken from the central line at 2, 6 and 24 h after operation. Antioxidant concentration in the peripheral, central and inferior mesenteric blood were similar, indicating that anaesthesia and surgical dissection had no effect. Levels decreased significantly in central and inferior mesenteric blood during and after clamping, but returned to normal by 24 h. These results confirm ischaemia-reperfusion phenomena in AAA repair.

Aged↗

Comparison of 5-hydroxy-2, 3-dihydrophthalazine-1, 4-dione and luminol as co-substrates for detection of horseradish peroxidase in enhanced chemiluminescent reactions.

The utility of 5-hydroxy-2, 3-dihydrophthalazine-1, 4-dione (HDP) as a co-substrate for the chemiluminescent detection of horseradish peroxidase was assessed. Several substituted aryl boronic acid derivatives (4-phenyl, 4-iodo) acted as potent enhancers of the peroxidase catalyzed reaction. Addition of chelating agents (EDTA) and surfactants (Tween-20 and [poly (vinylbenzyl)tributylphosphonium chloride-poly (vinylbenzyl) trioctylphosphonium chloride copolymer]) modulated background light emission and the intensity and duration of the signal from both HDP and luminol. However, HDP was found to be inferior to luminol in the peroxidase assay. Comparative studies revealed that at 500 amol of peroxidase the S/B was ten-fold higher using a commercial luminol-based signal reagent as compared with an HDP-EDTA-Tween-20 reagent (S/B t = 0 min 21.8 vs 1.7, S/B t = 10 min 17.8 vs 2.0).

Boronic Acids↗

Reliability and feasibility of a near patient test for C-reactive protein in primary care.

BACKGROUND: The applications of new diagnostic technologies such as near patient tests are relevant to the further development and potential of primary care. Through their use, doctors in the community may increase the accuracy of their diagnoses and improve their ability to monitor disease. A reliable indicator of disease activity in various clinical conditions is C-reactive protein (CRP) and a near patient test for this is now available, although there is little information on its use outside hospitals. AIM: A study was set up to evaluate the feasibility of using a novel near patient test for CRP in primary care to validate the results against the laboratory "gold standard' for CRP (Beckman Array) and to compare results with the usual inflammation test used in general practice. METHOD: Prospective recording of CRP as a near patient test on an "intention to investigate' basis, with validation of results against the Beckman Array system for CRP and hospital laboratory erythrocyte sedimentation rate results, in six general medical practices in Birmingham. Main outcome measures were change in local laboratory usage, characteristics of patients chosen for testing, use of quality control, and comparison of readings with results from the same sample sent to an independent laboratory. RESULTS: Tests of CRP levels were rarely requested before the study was undertaken. During the 3-month study period, 181 near patient tests were carried out, 146 (81%) to establish a diagnosis and the remainder for disease monitoring. Out of the tests, 67% were performed by general practitioners, mostly during the consultation itself. Using a cut-off level of 10 mg I-1, the near patient test and the Beckman Array gave results which agreed in 84% of cases. The sensitivity and specificity of the near patient test results were 97 and 79%, respectively. The predictive value of a positive result was 59% and that of a negative result was 99%. Cohen's Kappa was 62% and the overall mean bias for results in the range of the test was 6.11 mg I-1 (SE = 3.07 mg I-1). Each test took 6 min on average to perform, including all preparations, blood letting, performing the test and averaging the time for quality control estimations. The cost per test averaged pounds 1.72, rising to pounds 4.17 including labour, capital costs, quality controls and consumables (general practitioner performing the assay at average frequency found in this study). CONCLUSIONS: Measurement of CRP is rarely used in primary care and awareness of its value could be raised. This near patient test proved feasible for use by general practitioners and practice nurses. Its reliability compared with a laboratory result was satisfactory overall, and excellent with adequate operator technique.

Biomarkers↗

Site-specific alkaline phosphatase levels in gingival crevicular fluid in health and gingivitis: cross-sectional studies.

Using a recently developed chemiluminescent assay enabling alkaline phosphatase (ALP) quantification in nanolitre volumes of gingival crevicular fluid (GCF), we have investigated GCF ALP levels in health and in the presence of gingivitis. In gingival health, there was a site-specific pattern of ALP concentration with higher enzyme concentrations around the upper and lower anterior teeth. Furthermore, clinically normal sites that had been subjected to different levels of plaque control produced significantly different ALP levels, (p < 0.03). This indicates that biochemical components of GCF may be used to measure subclinical inflammatory status. The ratio of GCF to serum ALP varied from 6:1 to 11:1, suggesting that a major source of the enzyme is through local production. The main cross-sectional study of 30 patients with gingivitis (276 sites) demonstrated that total GCF ALP levels, collected over a 30-s sampling time were higher for a gingival index of 1 than of 0 (p < 0.014). There was no significant relationship between total GCF ALP and plaque levels of the enzyme, and analysis of plaque within the study group demonstrated very low levels of ALP, indicating that the enzyme is likely to be largely derived from the periodontal tissues. The ratio of GCF ALP levels to those of saliva within individuals was 530:1, thereby eliminating saliva contamination as a risk, when total GCF ALP is being measured.

Adult↗

Antioxidant status in controlled and uncontrolled hypertension and its relationship to endothelial damage.

Hypertension is associated with an increased risk of atherosclerosis. Free radical oxidative damage has been implicated in the atherogenic process. We measured levels of the antioxidants uric acid, thiols, vitamins C, A and E as well as the total antioxidant capacity in 21 normotensive controls, 22 patients whose hypertension was controlled on drugs and 30 patients with uncontrolled hypertension. Mean BPs in the groups were 125/76, 132/80 and 181/98 mmHg, respectively. When compared with controls, both hypertensive groups had significantly lower serum ascorbic acid (54 +/- 5 vs. 37 +/- 6 vs. 38 +/- 5 mumol/l, P < 0.05) and albumin-corrected thiol levels (9.91 +/- 0.18 vs. 8.69 +/- 0.20 vs. 8.92 +/- 0.19 mumol/g, P < 0.05). The levels of the other antioxidants did not differ significantly between the groups. Levels of von Willebrand factor, a marker of endothelial damage, were correlated with SBP but not with antioxidant status. We conclude that hypertensive subjects have lower levels of the antioxidants vitamin C and thiols and this may reflect greater oxidative consumption. The implications for atherogenesis and endothelial function and integrity in hypertension are discussed.

Adult↗