PubMed Health⌕ Search

Biomedical subjects

G I Bain

Publications and source records attributed to G I Bain.

At least 19 recordsLinked to original sources

Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. Surgical technique.

BACKGROUND: Radial head fractures often occur in association with other elbow fractures and soft-tissue injuries. Radial head replacement is indicated for irreparable radial head fractures associated with elbow instability. The purpose of this study was to analyze the results after treatment of such injuries with a titanium radial head prosthesis, repair of torn collateral ligaments, and early mobilization of the elbow. MATERIALS: Sixteen patients with sixteen Mason type-III radial head fractures and collateral ligament injury were treated with use of a titanium radial head prosthesis over a five-year period at the Royal Adelaide Hospital and Modbury Public Hospital in South Australia. The surgery was performed acutely in ten patients and was delayed an average of thirty-seven days (range, fifteen to seventy-nine days) in six. All patients were followed clinically and radiographically for a mean of 2.8 years (range, 1.2 to 4.3 years). RESULTS: Eight patients had an excellent result; five, a good result; and three, a fair result, according to the Mayo Elbow Performance Score. The three fair results occurred in patients with delayed surgery. The mean flexion contracture was 15 degrees (range, 0 degrees to 42 degrees ), with an average loss of 10 degrees (range, 0 degrees to 25 degrees ) of full flexion compared with that of the contralateral elbow. Both pronation and supination decreased an average of 12 degrees (range, 0 degrees to 45 degrees ) compared with that of the contralateral forearm. CONCLUSIONS: The results of treatment of Mason type-III radial head fractures with a monoblock titanium radial head prosthesis and soft-tissue reconstruction are satisfactory. Early mobilization of the elbow is important for the restoration of elbow range of motion and function.

Algorithms↗

Digitally assisted acromioplasty: the effect of interscalene block on this new surgical technique.

PURPOSE: Interscalene brachial plexus (ISBP) block has been shown to be safe and effective for shoulder surgery with significant benefits. The purpose of this study was to introduce the technique of digitally assisted acromioplasty and assess the effect of ISBP on rehabilitation. TYPE OF STUDY: Randomized controlled prospective trial. METHODS: In a randomized prospective trial of 40 patients undergoing acromioplasty under general anesthesia, 20 patients received an ISBP block (group 1) and 20 had no block (group 2). A digitally assisted acromioplasty was performed using a burr introduced via a posterior portal. The undersurface of the acromion was debrided, directing the burr with the surgeon's index finger introduced via a small lateral incision. Independent review was at day 1, day 2, week 1, week 6, and 1 year. RESULTS: Group 1 had significantly greater shoulder motion and shoulder score, and less pain and analgesic requirements on the first day. These differences did not persist. Both groups had improved pain and function over time compared with preoperative scores. CONCLUSIONS: ISBP provides superior initial results but does not offer any significant persistent functional or rehabilitative advantage in the medium to long term. Digitally assisted acromioplasty is simple to perform and does not violate the deltoid insertion.

Acromioclavicular Joint↗

Sigmoid notch osteoplasty for chronic volar instability of the distal radioulnar joint: a case report.

Chronic recurrent volar dislocation of the distal radioulnar joint is a rare condition for which many operative procedures have been described. We describe a case of painful dislocation on supination. Investigation of the distal radioulnar joint revealed the absence of degenerative arthritis and a flat sigmoid notch that permitted dislocation. The case was successfully treated by osteoplasty of the volar lip of the sigmoid notch to create a buttress that prevented volar dislocation.

Adult↗

Osteoprotegerin and receptor activator of nuclear factor kappaB ligand (RANKL) regulate osteoclast formation by cells in the human rheumatoid arthritic joint.

OBJECTIVE: This study investigated the involvement of the recently identified regulators of osteoclast formation RANKL [receptor activator of nuclear factor kappaB (RANK) ligand, osteoclast differentiation factor, TRANCE, osteoprotegerin ligand] and its natural inhibitor, osteoprotegerin (OPG), in the bone erosion of rheumatoid arthritis (RA). METHODS: mRNA was extracted from cells isolated from the pannus and synovial membrane regions of joints of 11 RA patients. Semiquantitative reverse transcription-polymerase chain reaction was carried out, and the isolated cells were also cultured to determine their ability to form osteoclasts. RESULTS: mRNAs encoding RANKL, RANK, OPG and macrophage-colony stimulating factor were expressed by cells isolated from RA joints. In addition, mRNA encoding for tumour necrosis factor apoptosis-inducing ligand and the osteoclast markers tartrate-resistant acid phosphatase and calcitonin receptor were also often expressed. Osteoclasts capable of forming resorption lacunae were generated from cells in the RA joints. At 50 ng/ml, recombinant OPG completely inhibited the resorptive activity of these cells. There was a significant correlation between the ratio of RANKL mRNA to OPG mRNA and the number of resorption pits produced (P = 0.028). CONCLUSION: These data suggest that RANKL is an essential factor for osteoclast formation by cells in the rheumatic joint and that OPG may prevent the bone erosion seen in RA joints.

Adult↗

Synthetic bone graft substitutes.

Replacement of extensive local bone loss is a significant clinical challenge. There are a variety of techniques available to the surgeon to manage this problem, each with their own advantages and disadvantages. It is well known that there is morbidity associated with harvesting of autogenous bone graft and limitations in the quantity of bone available. Alternatively allografts have been reported to have a significant incidence of postoperative infection and fracture as well as the potential risk of disease transmission. During the past 30 years a variety of synthetic bone graft substitutes has been developed with the aim to minimize these complications. The benefits of synthetic grafts include availability, sterility and reduced morbidity. The present article examines the relevance of synthetic bone graft substitutes, their mechanical properties and clinical application.

Aluminum Oxide↗

A systematic review of the content and quality of wrist outcome instruments.

OBJECTIVE: To assess the content and quality of published wrist outcome instruments using standardized criteria. DESIGN: An analytical study that examined 32 wrist outcome instruments sourced from textbooks, Medline (1951 to present) and Current Contents. MAIN MEASURES: The content of each instrument was classified into four categories: traditional measures (such as range of movement and strength), measures of the ability to perform daily activities, compensatory mechanisms used, and 'other'. Analysis included the frequency of assessment per category and the method of assessment. In addition, each instrument was graded using 13 quality criteria. Three criteria (scientific justification of the content and scoring system used, demographic utility) were considered to be essential. RESULTS: Eighty-two per cent of instruments reviewed for this paper contained traditional measures, of which most were assessed objectively. The ability to perform specific daily activities was assessed in 31% of the instruments whereas compensatory mechanisms were evaluated in only one instrument. These variables were not assessed in a consistent manner. Using the quality scoring system derived for this study, the quality of the instruments was generally poor. Only one instrument fulfilled all of the essential criteria. Only four instruments completely satisfied more than 50% of the criteria. CONCLUSIONS: Most wrist outcome instruments neglected to assess the impact of the disorder on the individual. Outcome was generally not expressed in functional terms or in terms that were relevant to each individual. The majority of the reviewed articles had poor quality. Thus use of these instruments may preclude sensitive evaluation of the efficacy of any intervention.

Activities of Daily Living↗

Surgical approaches to the elbow.

The recent explosion of interest in the elbow and the need for better surgical approaches, has produced numerous new approaches and the modification of other approaches, the result of which is a much shorter but more useful list of surgical approaches. Surgeons who perform a large number of elbow procedures have found that these approaches permit them to perform the majority of elbow procedures with only one skin incision, usually a straight posterior midline incision. Knowledge of the deep intermuscular and internervous intervals allows the surgeon to expose the elbow circumferentially through one skin incision. This approach has been associated with fewer wound complications and has allowed immediate active motion of the elbow.

Elbow↗

Anatomical reduction of intra-articular fractures of the distal radius. An arthroscopically-assisted approach.

We treated 31 intra-articular fractures of the distal radius by arthroscopically-assisted reduction and percutaneous fixation with Kirschner (K-) wires. Tears of the triangular fibrocartilage (58 %), scapholunate (85 %) and lunotriquetral (61%) instability and osteochondral lesions (19%) were also treated. A total of 26 patients was independently reviewed at an average of 19 months. The mean pain score was 1.3/10, the range of movement 79% and the grip strength 90% of the contralateral wrist. Using the New York Orthopaedic Hospital score, 88% were graded excellent to good. On follow-up radiographs, 65% had no step and 31% had a step of < or =1 mm. Pain was significantly related to the size of the step. There was a significant difference in the incidence of persistent scapholunate diastasis and the Leibovic and Geissler grade (p < 0.01): I (0%), II (0%), III (42%) and IV (100%). We recommend anatomical reduction and acceptance of a step of <1 mm since the size of the step is related to the incidence of pain.

Adult↗

An overview of distal radial fractures.

Fractures of the distal radius include a wide spectrum of fracture patterns. As well as involving the distal radius, these injuries can involve the wrist, the distal radio-ulnar joint and the distal ulna. The management of these injuries is consequently diverse, ranging from a plaster cast to advanced surgery. The principles of treatment are to reduce and maintain the reduction by restoring the radial height, volar tilt and intra-articular step. The acceptable reduction is to have radial height to within 2 mm of the ulnar, volar tilt greater than 0 degree and intra-articular step less than 1 mm. The present paper reviews the current concepts in the diagnosis, management and complications of distal radial fractures.

Emergency Medical Services↗

A review of complex trauma to the elbow.

This paper presents a review of common complex elbow traumatic disorders. It presents an algorithm to aid in the management of these cases and discusses indications for radial head replacement and dynamic external fixateurs.

Fractures, Bone↗

Internal suture for mallet finger fracture.

An internal suture technique has been used for mallet finger fractures involving at least 30% of the articular surface. It provides fixation without a button or transfixion of the fragment. An independent retrospective review was conducted of ten patients at a mean follow-up of 17 months. Mean visual analogue score (0 to 10) for pain was 2.4 and satisfaction 7.9. Mean active range of motion was 13 to 49 degrees, passive motion was 2 to 56 degrees, pinch strength of effected finger to thumb was 3.8 kgf (81% of the opposite finger), grip strength 37.9 kgf (95% of the opposite hand). All fractures united and there were no neuromas. Complications included two nail deformities, a superficial infection and a pin track infection. One patient with a crush injury continued to have pain despite an arthrodesis.

Adolescent↗

Measurement of the scaphoid humpback deformity using longitudinal computed tomography: intra- and interobserver variability using various measurement techniques.

The intra- and interobserver variability of 3 techniques for measuring the humpback deformity of 37 scaphoids using longitudinal computed tomography was assessed. The 3 measuring techniques were the lateral intrascaphoid angle, the dorsal cortical angle, and the height-to-length ratio. The intraobserver reliability of the intrascaphoid angle was poor; the dorsal cortical angle was moderate to excellent, and the height-to-length ratio was excellent. The interobserver reliability of the intrascaphoid angle was poor to moderate, the dorsal cortical angle was moderate to excellent, and the height-to-length ratio was moderate to excellent. For all 3 observers, the intra- and interobserver reliability was the best for the height-to-length ratio and worst for the intrascaphoid angle. The height-to-length ratio is the most reproducible method of assessing the humpback deformity. Clinical correlation is required to establish whether the height-to-length ratio will be of value in predicting the outcome of fractures of the scaphoid.

Carpal Bones↗

Dynamic external fixation for injuries of the proximal interphalangeal joint.

Pain, stiffness, instability and degenerative arthritis are common sequelae of complex fracture-dislocations of the proximal interphalangeal (PIP) joint. Operations were carried out to obtain stability, followed by application of a dynamic external fixator in 20 patients with a mean age of 29 years. This provided stability and distraction, and allowed controlled passive movement. Most (70%) of the patients had a chronic lesion and the mean time from injury to surgery was 215 days (3 to 1953). The final mean range of movement was 12 to 86 degrees. Complications included redislocation and septic arthritis, which affected the outcome. Four pin-track infections and two breakages of the hinge did not influence the result. The PIP Compass hinge is a useful adjunct to surgical reconstruction of the injured PIP joint.

Adolescent↗

Operative fluoroscopy in hand and upper limb surgery. One hundred cases.

We reviewed the use of a low radiation portable fluoroscopy unit in 100 patients. The most common indication was closed reduction of distal radial fractures. Fracture and joint stability were assessed on the real-time monitor and stored on videotape. Static images were stored on thermographic paper. Fluoroscopically guided joint injections and localization of implants, foreign bodies and bone tumours were performed. Fluoroscopy is a useful adjunct to arthroscopic assisted fracture reduction and other arthroscopic procedures such as distal ulnar resection. These new generation units produce superior resolution images, are easy to manoeuvre and do not require a radiographer.

Bone Neoplasms↗

Treatment of humeral shaft fractures with the Seidel intramedullary nail.

BACKGROUND: The use of intremedullary nails for the management of humeral shaft fractures has been controversial. Recently, the Seidel nail has become available. The purpose of this study was to review our initial experience with the Seidel nail. METHODS: A retrospective clinical and radiographic review of 25 consecutive patients treated with Seidel intramedullary humeral nail was performed. The nail was used for non-union in 10 patients, delayed union in four, acute fracture in eight and pathological fracture in three. Eighteen of the 19 survivors were clinically reviewed at an average of 15 months (range 8-15). Pain, function, satisfaction, shoulder power, range of motion and clinical outcome were graded using the UCLA shoulder score. RESULTS: Pain was present at the shoulder in four patients and at the fracture site in nine. Average shoulder abduction was 99 degrees and nine patients could not abduct the shoulder past 90 degrees. Sixty-six percent of patients reviewed were graded as only fair or poor using the UCLA shoulder score. In three patients rotational control was not achieved with the distal locking device at the time of surgery. Complications included non-union in 10 patients and three intra-operative fractures. CONCLUSIONS: Non-union was more likely to occur if rotational control was not obtained, or if the patient had the nail inserted for a previous non-union. Use of the Seidel nail frequently leads to shoulder pain and dysfunction. The distal locking device is unreliable and predisposes to non-union. We do not recommend the continued use of the Seidel nail.

Adolescent↗

Longitudinal computed tomography of the scaphoid: a new technique.

Computed tomography is increasingly utilized for the evaluation of scaphoid fracture, nonunion, and deformity. We have developed a new technique of positioning patients while performing longitudinal computed tomography of the scaphoid. With the wrist positioned in radial deviation and neutral flexion, greater patient comfort is provided and immobilization of the wrist is not required. A reproducible image can be obtained with attention to the alignment of the scanning plane to the longitudinal axis of the scaphoid on the scout image, and verified with the "target sign". High resolution images, which clearly demonstrate the abnormalities of the scaphoid, can be produced even if the patient has a cast on the wrist or if there is hardware in situ.

Carpal Bones↗

Matched hemiresection interposition arthroplasty of the distal radioulnar joint.

Since 1986 the senior author has performed a matched hemiresection with retinacular/capsular interposition for patients with painful disorders of the distal radioulnar joint. A retrospective review of 55 wrists was performed by an independent hand surgeon and hand therapist. Forty-nine of 54 wrists in the surviving patients were clinically and radiographically reviewed with an average follow-up interval of 36 months. Subjective assessment included a visual analog rating of pain improvement and satisfaction with treatment. Objective assessment included examination of range of motion, strength, stability, and standardized functional testing with the Jebsen and Minnesota Rate of Manipulation tests. Thirty-five patients reported pain improvement and 41 patients were satisfied. The range of supination and pronation increased from 54 degrees and 67 degrees, respectively, to 72 degrees and 72 degrees. Functional ability as measured by the Jebsen test was similar to the contralateral wrist. Patients had most difficulty turning large objects. The clinical, objective, functional, and x-ray films results correlated poorly with pain improvement and patient satisfaction. Complications included one infection, one reflex sympathetic dystrophy, one neuroma of the dorsal sensory branch of the ulnar nerve, and four cases of ulnar-carpal impaction. Pain relief was the primary determinant of patient satisfaction and should be considered the indication for surgery.

Adolescent↗

Percutaneous A1 pulley release: a cadaveric study.

Percutaneous A1 pulley release was performed on 17 fresh-frozen cadaveric hands with a 14-gauge angiocath needle. Each hand was then explored to assess the adequacy of release and the degree of injury to adjacent structures. Complete release of the A1 pulley was obtained in 45 of the 66 fingers and in 10 of the 17 thumbs. Significant injury to the flexor tendons was observed in two digits. All tendon injuries occurred along the line of the fibers. There were no digital nerve injuries. The release was within 2 mm of a thumb digital nerve in seven hands and the little finger ulnar digital nerve in two. In the thumb, the close proximity of the digital nerves makes percutaneous trigger digit release potentially hazardous. With the little finger held in abduction the risk of digital nerve injury or inadequate release is reduced. Percutaneous trigger finger release can be safely performed in the index, long, and ring fingers.

Cadaver↗