Publications and source records attributed to G Iberer.

5 recordsLinked to original sources

Detection of aggregate formation during production of human immunoglobulin G by means of light scattering.

In human immunoglobulin preparations with a concentration of 50 mg/ml aggregate formation below 0.3% is difficult to quantify. Such small traces may later be responsible for reduced stability and therefore this generation during the process must be prevented. The influence of process conditions on the conformational changes and subsequent aggregation of immunoglobulins were assessed by size-exclusion chromatography (SEC), UV and static light scattering (LS) detection. This work focused on pH-adjustment experiments since several pH adjustments are required during the production of intravenous immunoglobulin G. Experiments in a labscale were made varying process conditions in a narrow range. It was possible to detect differences concerning the formation of aggregates dependent on these small variations of process conditions.

Humans↗

Analysis of aggregates of human immunoglobulin G using size-exclusion chromatography, static and dynamic light scattering.

Large aggregates (Mr: 10(6)-10(7) g/mol) of human immunoglobulins are present in extremely small concentrations in IgG preparations (<0.1%). Traces of large protein aggregates cannot be determined by conventional size-exclusion chromatography (SEC) using UV detection due to limitations in sensitivity. The conventional analysis of IgG by SEC is limited to dimers and oligomers. Using light scattering it is possible to determine significant differences concerning the aggregate composition and the extent of protein aggregation in samples of different process steps. Two different pilot preparations were analyzed by SEC with UV and static light scattering detection and compared to dynamic light scattering in the batch mode. The change of large aggregates could be monitored and data were corroborated by dynamic light scattering.

Chromatography, Gel↗

Improved performance of protein separation by continuous annular chromatography in the size-exclusion mode.

In size-exclusion chromatography (SEC), proteins and peptides are separated according to their molecular size in solution. SEC is especially useful as an effective fractionation step to separate a vast amount of impurities from the components of interest and/or as final step for the separation of purified proteins from their aggregates, in a so-called polishing step. However, the throughput in SEC is low compared to other chromatographic processes as good resolution can be achieved only with a limited feed volume (i.e., maximal approximately 5% of the column volume can be loaded). This limitation opposed widespread application of conventional SEC in industry despite its excellent separation potential. Therefore a continuous separation process (namely preparative continuous annular chromatography) was developed and compared to a conventional SEC system both using Superdex 200 prep grade as sorbent. An immunoglobulin G sample with a high content of aggregates was chosen as a model protein solution. The influence of the feed flow-rate, eluent flow-rate and rotation rate on the separation efficiency was investigated. The height equivalent to a theoretical plate was lower for preparative continuous annular chromatography which could be explained by reduced extra column band broadening. The packing quality was proved to be identical for both systems. The productivity of conventional batch SEC was lower compared to continuous SEC, consequently buffer consumption was higher in batch mode.

Chromatography, Gel↗

Vitronectin in clotting factor IX concentrates.

Highly purified, plasma-derived factor IX (FIX) concentrates are produced in large part by a combination of anion exchange and heparin affinity chromatography. However, the concentrates still contain some accompanying proteins. The main impurity has turned out to be the adhesive glycoprotein, vitronectin. It occurs in concentrates exclusively in its multimeric form, in contrast to the situation in plasma. The multimeric vitronectin can be removed either by nanofiltration with a crossflow system or by size-exclusion chromatography. When these FIX concentrates are used as therapeutic agents, the fact has to be taken into account that considerable amounts of multimeric vitronectin are given to the patient. The physiological consequences of the dosage of this protein have not yet been investigated. Although no thrombogenicity has been reported in connection with the above-mentioned FIX concentrates, we recommend that the impurity should be removed from the preparation with the methods described here.

Blood Coagulation Factors↗

Continuous removal of protein aggregates by annular chromatography.

The removal of polymeric proteins from their monomers is a frequently encountered separation task, especially in the polishing step of therapeutic proteins. Continuous separation of protein polymers from monomers by annular chromatography using size exclusion chromatography has been studied regarding the resolution, recovery, fouling, and productivity and has been compared to conventional chromatography. An IgG preparation rich in aggregates was used as a model protein mixture. Under conditions that maximized the throughput, the polymers could be separated from the monomers, but baseline separation could not be achieved. Baseline separation was also not possible in batch mode using equivalent conditions, which was also confirmed by computer simulation. For separation of the aggregates from the product the entire available separation space (360 degrees ) was indispensable. Therefore only cyclic, discontinuous regeneration could be carried out. Loading was identified as a critical step, since the concentrated protein solution evaded into the headspace instead of migrating into the gel where viscous fingering often occurs in conventional chromatography. The productivity of annular chromatography was two times higher than that of the conventional batch chromatography, and the buffer consumption was reduced to half the conventional value. These two benefits are especially important for protein separation processes that suffer from low loadability, such as size exclusion chromatography. We have demonstrated that size exclusion can be performed on an industrial scale when it is run continuously with the aid of a pressurized annular chromatograph.

Chromatography, Gel↗