PubMed Health⌕ Search

Biomedical subjects

G J Diebold

Publications and source records attributed to G J Diebold.

6 recordsLinked to original sources

Photoacoustic point source.

We investigate the photoacoustic effect generated by heat deposition at a point in space in an inviscid fluid. Delta-function and long Gaussian optical pulses are used as sources in the wave equation for the displacement potential to determine the fluid motion. The linear sound-generation mechanism gives bipolar photoacoustic waves, whereas the nonlinear mechanism produces asymmetric tripolar waves. The salient features of the photoacoustic point source are that rapid heat deposition and nonlinear thermal expansion dominate the production of ultrasound.

Journal Article↗

Laser fluorometric determination of aflatoxin B1 in corn.

A 2-step chromatographic separation, using both thin layer chromatography (TLC) and high pressure liquid chromatography (HPLC), in conjunction with the high sensitivity of laser fluorometry permits extension of the detection limits of aflatoxin contamination in corn to 0.1 ppb (microgram/kg) with a 26% root mean square variation. Aflatoxin B1 is extracted from corn with water-methanol and cleaned up by TLC. The recovery of aflatoxin from the TLC plates was linear from 10 to 1000 pg. Aflatoxin B1 is converted to the more highly fluorescent B2A derivative by treatment with 1N HCl. Experiments with aflatoxin B1 standard establish a constant conversion to B2A over approximately 3 orders of magnitude in B1 concentration. An extract of the B2A aflatoxin derivative is injected onto a reverse phase HPLC column. A flowing droplet of eluant is irradiated by an amplitude-modulated 325 nm He-Cd ion laser beam, and fluorescence from the droplet is detected by a lock-in amplifier in phase with the laser modulation. Several chromatograms are presented that demonstrate the capability of this procedure for removing interfering components in the corn extract.

Aflatoxins↗

Laser fluorimetry: subpicogram detection of aflatoxins using high-pressure liquid chromatography.

The use of high-pressure liquid chromatographic separation in conjunction with laser-induced fluorescence detection permits the analysis of trace fluorescent species at new limits of sensitivity. This technique was applied to the carcinogens aflatoxins B1, B2, G1, and G2, which were linearly quantitated to 7.5 x 10(-13) gram. The procedure consists of forming more fluorescent aflatoxin derivatives, eluting the aflatoxins from a reverse-phase column, focusing the 325-nanometer output of a helium-cadmium ion laser into a suspended droplet of the eluent, and measuring the resulting fluorescence using phase-sensitive detection.

Aflatoxins↗