The effects of out-of-plane rotations on two dimensional portal image registration in conformal radiotherapy of the prostate.

PURPOSE: Rotations of the patient out of the image plane can significantly degrade the accuracy of two-dimensional (2D) image registration. This study determines the magnitude of the geometric errors introduced by 2D image registration as a result of out-of-plane rotations, and analyzes the dosimetric effects of these errors. METHODS AND MATERIALS: The magnitude of the errors introduced by 2D registration were determined by comparing orthogonal view portal images of a rotated phantom to simulator reference images of the same phantom without rotation. Dosimetric effects were calculated for three-dimensional (3D) conformal prostate treatments by applying the registration errors to patient treatment plans. The calculations were performed using a modified version of the dose calculation software used in our Cancer Center for 3D treatment planning based on computed tomography (CT). A method to detect out-of-plane rotations, specific to pelvic treatments, is introduced that uses the relative displacement of the centers of gravity of the acetabula in lateral images. RESULTS: The inherent uncertainty in the registration algorithm was 0.6 +/- 0.5 mm in translation and 0.7 +/- 0.8 degree in rotation within the image plane. For a 2 degrees out-of-plane rotation, the errors increase to 2.3 +/- 1.0 mm and 1.2 +/- 1.1 degrees. In some clinically realizable treatment scenarios it was observed that the errors introduced by the registration procedure could result in an overdosing of the rectal wall. The method to detect out-of-plane rotations was found to have an accuracy of better than 1 degree for rotations of less than 10 degrees. CONCLUSIONS: The errors introduced to the patient position by 2D image registration have dosimetrically significant consequences for out-of-plane rotations of 2 degrees or more. However, when used in conjunction with the method to detect out-of-plane rotations, 2D registration software was found to cause insignificant dose errors and, thus, become a more reliable and accurate clinical tool.

Humans↗

Effect of ocular implants of different materials on the dosimetry of external beam radiation therapy.

PURPOSE: To study the attenuation and scattering effects of ocular implants, made from different materials, on the dose distributions of a 6 MV photon beam, and 6, 9, and 12 MeV electron beams used in orbital radiotherapy. METHODS AND MATERIALS: Central axis depth-dose measurements were performed in a polystyrene phantom with embedded spherical ocular implants using film dosimetry of a 6 MV photon beam and electron beams of 6, 9, and 12 MeV energy. The isodose distributions were also calculated by a computerized treatment planning system using computerized tomography (CT) scans of a polystyrene phantom that had silicone, acrylic, and hydroxyapatite ocular implants placed into it. RESULTS: Electron beam dose distributions display distortions both on the measured and calculated data. This effect is most accentuated for the hydroxyapatite implants, for which the transmissions through ocular implants are on the order of 93% for the 6 MV photon beam, and range from 60% for 6 MeV electrons to 90% for 12 MeV electrons. CONCLUSION: We studied the effect of ocular implants of various materials, embedded in a polystyrene phantom, on the dose distributions of a 6 MV photon beam, and 6, 9, and 12 MeV electron beams. Our investigations show that while 6 MV photons experience only a few percent attenuation, lower energy electron beam with 60% transmission is not a suitable choice of treating tumors behind the ocular implants.

Colloids↗

Multileaf collimation versus alloy blocks: analysis of geometric accuracy.

PURPOSE: To compare the misalignment error due to the fabrication of custom lead alloy blocks with the displacement error introduced by the finite resolution of a multileaf collimator relative to the prescribed smooth apertures. METHODS AND MATERIALS: Treatment field apertures for randomly selected patients for four clinical sites were obtained at various stages of the block fabrication process. These apertures and the corresponding multileaf collimator (MLC) apertures for each field were superimposed with the smooth apertures prescribed by physicians. The deviations from the prescribed apertures were measured at 10 degrees intervals. Comparisons of the magnitude and frequency of errors from block fabrication with those from the geometric displacements introduced by the finite leaf width of the multileaf collimator were made. RESULTS: The degree of conformity of the multileaf collimator is treatment-site dependent as, in general, are the shapes of fields. For three of the four sites examined, the multileaf collimator apertures track the prescribed apertures at least as accurately as custom blocking when the block design, construction, mounting, and alignment on the treatment machine are considered. CONCLUSIONS: The geometric conformality of multileaf collimation is comparable to, and in some cases superior to, that of custom blocks.

Alloys↗

Analysis of clinical complication data for radiation hepatitis using a parallel architecture model.

PURPOSE: The detailed knowledge of dose volume distributions available from the three-dimensional (3D) conformal radiation treatment of tumors in the liver (reported elsewhere) offers new opportunities to quantify the effect of volume on the probability of producing radiation hepatitis. We aim to test a new parallel architecture model of normal tissue complication probability (NTCP) with these data. METHODS AND MATERIALS: Complication data and dose volume histograms from a total of 93 patients with normal liver function, treated on a prospective protocol with 3D conformal radiation therapy and intraarterial hepatic fluorodeoxyuridine, were analyzed with a new parallel architecture model. Patient treatment fell into six categories differing in doses delivered and volumes irradiated. By modeling the radiosensitivity of liver subunits, we are able to use dose volume histograms to calculate the fraction of the liver damaged in each patient. A complication results if this fraction exceeds the patient's functional reserve. To determine the patient distribution of functional reserves and the subunit radiosensitivity, the maximum likelihood method was used to fit the observed complication data. RESULTS: The parallel model fit the complication data well, although uncertainties on the functional reserve distribution and subunit radiosensitivity are highly correlated. CONCLUSION: The observed radiation hepatitis complications show a threshold effect that can be described well with a parallel architecture model. However, additional independent studies are required to better determine the parameters defining the functional reserve distribution and subunit radiosensitivity.

Hepatitis↗

Strategy for dose escalation using 3-dimensional conformal radiation therapy for lung cancer.

PURPOSE: Local failure is a major obstacle to the cure of locally advanced non-small-cell lung cancer. 3-Dimensional conformal radiation therapy (3-DCRT) selects optimal treatment parameters to increase dose to tumor and reduce normal tissue dose, potentially permitting dose escalation. There are several ongoing trials of dose escalation using 3-Dimensional conformal radiation therapy for non-small-cell lung cancer. We performed this analysis to determine if data derived from dose volume histograms could be used as the basis for designing the method of dose escalation in these trials. METHODS AND MATERIALS: Between 1990 and 1993, 31 patients were treated with 3-DCRT and had complete normal tissue dose volume histograms created as part of the planning process. The stage distribution was stage I/II 13%, stage IIIa in 45%, and stage IIIb in 42%. The median radiation dose to gross disease was 70.2 Gy (52.2-72 Gy). Elective mediastinal irradiation (50.4 Gy) was administered to 52% (16/31) of patients. RESULTS: The major toxicity encountered in this experience was pulmonary. Dose-volume-histogram data were used to analyze the predictors of toxicity and showed a correlation between risk of pulmonary toxicity and indices of dose to lung parenchyma. Grade 3 or higher pulmonary toxicity occurred in 38% (3/8) of pts with >30%of lung volume receiving > or =25 Gy, versus 4% (1/23) of pts. with < or = 30% lung receiving > or = 25 Gy (p=0.04). Grade 3 or higher pulmonary toxicity occurred in 29% (4/14) of patients with a predicted pulmonary normal tissue complication probability of 12% or higher versus 0% (0/17) in patients with a predicted probability of less than 12% (p=0.03). The single fatality occurred in a patient with a calculated pneumonitis probability of 85% and a high percent (49%) lung volume receiving >= 25 GY. CONCLUSION: This preliminary experience demonstrates a correlation between lung dose-volume-histogram data and the risk of severe pulmonary toxicity. This provides an opportunity to modify the method of radiation dose escalation. Dose-volume-histogram data can allow escalation according to the risk to the lung parenchyma (which is the major organ of concern) rather than escalation according to tumor dose levels. Because of teh major inter-patient variability of intrathoracic tumor bulk and anatomic distribution, this strategy is intuitively appropriate. This approach may facilitate completion of dose escalation studies and identification of maximum tolerable pulmonary dose levels.

Adult↗

Beam characteristics of a new generation 50 MeV racetrack microtron.

The first of a new generation of microtron accelerators has been installed and tested. It is currently in use for multisegment conformal radiotherapy at our institution. The unit produces x rays and electrons from 10 to 50 MeV in 5 MeV increments. It incorporates a 64 leaf, doubly focused multileaf collimator (MLC), which can be used to shape x-ray and electron beams. Both x-ray and electron beams are produced by magnetically scanning the electron beams from the accelerator. The new generation unit incorporates a purging magnet to sweep away any primary or secondary electrons that pass through the target(s). In this paper, the beam characteristics of the accelerator that were studied during acceptance testing are described. Representative examples of depth doses, beam profiles, output factors, and elementary beam distributions are presented and discussed, in comparison with the earlier generation of microtron accelerators and with other radiotherapy machines.

Humans↗

Effects of beam modifiers and immobilization devices on the dose in the build-up region.

PURPOSE: To analyze the effect that immobilization devices used in conjunction with beam modifiers may have on the dose to the skin and build-up region. METHODS AND MATERIALS: Central axis depth dose measurements were made in a polystyrene phantom in the build-up regions using the 6 and 15 MV photon beams, at two different source-to-phantom distances, and various field sizes. The effects of acrylic blocking trays, lead wedges, and cerrobend blocks were assessed in conjunction with the enhancement of dose in the build-up region due to immobilizing devices using plaster and thermoplastic casting materials of different thicknesses. RESULTS: For the 6 MV photons, solid (3 mm) thermoplastic casting material was found to have the greatest effect on surface dose: for a 12 x 12 cm field we measured 79% of maximum dose when treating through the material versus 22% of maximum dose when no beam modifiers or immobilization devices are used. Measurements were also made to evaluate the effect of the immobilization of patients receiving three-dimensional conformal treatments using a 15 MV photon beam. CONCLUSIONS: The relevance of these results to treatments in the pelvis, breast, and head and neck regions is discussed. For 6 MV beams, special consideration should be given if the need arises to treat through the immobilization device, as unacceptable skin reactions may result.

Dose-Response Relationship, Radiation↗

Neoadjuvant hormonal therapy improves the therapeutic ratio in patients with bulky prostatic cancer treated with three-dimensional conformal radiation therapy.

PURPOSE: To determine the extent of reduction of volume of normal tissue structures exposed to high doses of radiation therapy (RT) after administration of neoadjuvant hormonal therapy (NHT) in patients with bulky, geometrically unfavorable prostatic cancers. METHODS AND MATERIALS: Twenty-two patients with bulky prostatic cancers were treated with a 3 month course of neoadjuvant leuprolide acetate and eulexin prior to three-dimensional (3-D) conformal radiotherapy. Patients were included if 3-D treatment planning revealed that either > 30% of the rectal wall would receive 95% of the prescription dose (D95) (n = 13); > or = 50% of the bladder wall would receive D95 (n = 10); or that any volume of small bowel would receive > or = 65% of the prescription dose (n = 16). All patients underwent simulation and conformal treatment planning before and after NHT. Pre and posthormone cumulative dose volume histogram (DVH) calculations for all normal tissue structures were analyzed and compared for each patient. RESULTS: The median percentage of target volume reduction after NHT was 25% (range: 3-52%). Ten of 13 patients (78%) whose prehormone rectal DVH demonstrated > 30% of the rectal wall receiving D95 responded to NHT with a median 25% (range: 16-48%) reduction of rectal volume receiving the D95. A median reduction of 50% (range: 6-64%) of the bladder volume receiving D95 was observed in nine of ten patients (90%), while 13 of 16 (81%) showed a reduction of small bowel volume to a median percentage of 88% (range: 67-100%) of the prehormonal values. CONCLUSION: Neoadjuvant hormonal therapy is an effective method for decreasing the size of bulky prostatic tumors as well as for optimizing the geometry of the target volume in relation to the adjacent normal tissue structures prior to radiation therapy. Such an approach allows for reduction of the volume of normal tissues exposed to high doses in the majority of treated patients. Currently, studies are underway to determine whether NHT will lead to a decreased likelihood of long-term complications associated with radiotherapy of bulky, geometrically unfavorable prostatic tumors, and permit the safe delivery of escalated dose levels using conformal treatment techniques.

Aged↗

Three-dimensional conformal radiation therapy in locally advanced carcinoma of the prostate: preliminary results of a phase I dose-escalation study.

PURPOSE: The acute morbidity of doses of 64.8-75.6 Gy and preliminary observations of late complications and tumor response using 3-dimensional conformal radiation therapy in carcinoma of the prostate are assessed. METHODS AND MATERIALS: 123 patients (Stage A2-12, B1-17, B2-43, C-51) were irradiated to the prostate and seminal vesicles using a 3-dimensional conformal radiation therapy technique. The median follow-up time was 15.2 months. The minimum tumor dose was 64.8-66.6 Gy in 49 patients, 70.2 Gy in 46, and 75.6 Gy in 28. Toxicity was scored according to the Radiation Therapy Oncology Group morbidity grading system. RESULTS: This technique of 3-dimensional conformal radiation therapy was well-tolerated with minimal acute morbidity. Only 32% of patients had grade 2 or 3 acute morbidity requiring short-term medication for relief of urinary symptoms or diarrhea. Only one patient (0.8%) has so far developed a severe (grade 4) late complication. Serum prostate specific antigen concentrations normalized in 67% of patients (64/96) within 1-14 months (median 4.5 months) after treatment and were progressively decreasing at last measurement in an additional 22% (21/96). Abnormal rising prostate specific antigen levels were observed in 15 patients, 11 of whom have already developed other evidence of relapsing disease. CONCLUSION: Acute toxicity for the doses tested with this 3-dimensional conformal radiation therapy technique is reduced compared to traditional treatment techniques, and the initial tumor response as assessed by prostate specific antigen measurement is highly encouraging with prostate specific antigen levels returning to normal in the majority of patients. Based on these results, a further increase of the dose to 81 Gy has been implemented in accordance with the schema of an ongoing Phase I dose-escalation study.

Adenocarcinoma↗

The potential and limitations of the inverse radiotherapy technique.

The objective of the work presented in this paper is to explore the scope of the applicability of the inverse radiotherapy technique for designing optimized intensity distributions to achieve a desired dose distribution. A specified desired uniform dose to the target volume is inverted, subject to constraints on the surrounding normal tissue dose, to produce optimum intensity distributions in a set of beams arranged around the target volume. We employed the inverse technique and software developed by Bortfeld and evaluated results both qualitatively and quantitatively using dose distribution displays, dose-volume histograms and biological indices including tumor control probability and normal tissue complication probabilities. So far we have applied this methodology to prostate and lung treatment plans. For prostate the inverse technique produces satisfactory approximations of the desired dose distributions. However, for lung its performance is considerably inferior. Our investigations point to a number of factors for this difference, the primary ones being differences in the tolerance doses of neighboring normal tissues, magnitudes of volume effect, tissue architectures, and the achievability of the specified desired dose distributions. We conclude that, for certain clinical situations, it is not sufficient to specify the objectives of optimization purely in terms of the desired pattern of the dose. The objectives must also include dose-volume effects and biological indices. Furthermore, the mathematics of optimization must be able to incorporate these factors into the process. We find that the inverse technique is not suitable for situations where dose-volume considerations and biological indices are important and that other methods of optimization of intensity distributions should be explored.

Adenocarcinoma↗

Three-dimensional conformal radiation therapy in localized carcinoma of the prostate: interim report of a phase 1 dose-escalation study.

Acute morbidity, late complications and tumor response were evaluated in 324 prostate cancer patients treated with 3-dimensional conformal radiation therapy in a phase I dose-escalation study. This radiotherapy technique targeted the prostate and seminal vesicles but effectively excluded the surrounding normal tissues. The minimum tumor dose was 64.8 to 66.6 Gy. in 87 patients, 70.2 Gy. in 138, 75.6 Gy. in 69 and 81.0 Gy. in 30. The treatment was well tolerated with minimal acute morbidity, observed in 15% of the patients who required medication for relief of rectal symptoms and in 34% for urinary symptoms. Two patients (0.6%) to date have had grades 3 and 4 late complications (Radiation Therapy Oncology Group morbidity grading system). The 3-year actuarial probability of survival with a normal serum prostate specific antigen level was 97% for patients with stages T1c and T2a, 86% with stage T2b, 60% with stage T2c and 43% with stage T3 disease. A multivariate analysis demonstrated that initial prostate specific antigen (20 ng./ml. or less versus more than 20 ng./ml.), stage (T2c or less versus T3) and Gleason score (6 or less versus 7 or more) were each significant independent variables that affected subsequent chemical relapse. The acute and long-term toxicities have been less compared with traditional treatment techniques. After the maximal tolerable dose with 3-dimensional conformal radiotherapy is established, future studies will test whether high dose conformal therapy has the potential to improve local tumor control and survival of patients with localized prostatic carcinoma.

Adenocarcinoma↗

Analysis of the photon beam treatment planning data for a scanning beam machine.

The characteristics of photon beams from the Scanditronix MM50 radiation therapy machine that are necessary for treatment planning are described. The MM50 uses a scanning beam instead of a conventional flattening filter to achieve flat dose distributions. At each beam energy, a scan pattern is chosen, depending on the field size; the small scan pattern (S) is used for field sizes up to 10 x 10 cm, the medium scan pattern (M) is used for field sizes up to 20 x 20 cm, and the large scan pattern (L) is used for the larger field sizes. The dose distributions of the beams associated with the 10 MV S, M, and L scan patterns, the 25 MV S, M, and L patterns, and the 50 MV S and M patterns are described. The data reported includes central axis data, beam profiles, and output factors. In addition to the measured data, our dose calculation model requires a pencil beam kernel for each beam. The kernel is constructed using the average photon energy spectrum, which is generated using a Monte Carlo simulation of the MM50. The simulation, based on EGS4, is also used to generate the radial variation of fluence and energy fluence, which is required by a new dose calculation model that does not require the measurement of beam profiles. The Monte Carlo generated data; the photon energy spectrum, the fluence, and the energy fluence are presented.

Biophysical Phenomena↗