Mean deviation fluctuation in eyes with stable Humphrey 24-2 visual fields.

AIM: To describe the expected fluctuation in the mean deviation (MD) scores on a large, long-term series of stable visual field reports for particular grades of defect in order to give clinicians an aid to the correct diagnosis of glaucomatous progression. METHOD: Visual field reports of subjects with five reliable consecutive Humphrey 24-2 visual fields, recorded over a period of at least 3 years, were scored using the Advanced Glaucoma Intervention Study (AGIS) system. The AGIS scores of the first and last visual fields were required to be identical. RESULTS: A total of 202 eyes from 202 patients were used in the study, with a total of 1010 visual fields being used in the analysis. Visual fields with no defect (AGIS score 0) had a 99% confidence interval (CI) of 0.3 dB, mild defects 0.4 dB, moderate defects 0.8 dB, severe 1 dB, and 1.3 dB for end-stage defects when considering variation of MD scores. Using a one-way ANOVA incorporating all stages showed very little fluctuation throughout the series (P=0.96). The correlation between the CI and grade of field defect showed a good positive correlation (r=0.7, P=0.0003) indicating an increase in CI as field defects worsen. CONCLUSION: When considering a series of reliable visual fields in a stable eye, one should expect only very little fluctuation in the MD, indicating that an increase in the MD beyond that of the 99% CI described may suggest progression. The reliability indices of the visual field test should be regarded as a primary consideration when assessing visual fields.

Age Factors↗

Tear film lipid layer thickness and ocular comfort after meibomian therapy via latent heat with a novel device in normal subjects.

AIM: This study measures changes in tear film lipid layer thickness (LLT) and ocular comfort in normal subjects after 10 min use of a novel device, which delivers meibomian therapy with latent heat. The device is designed to promote the release of meibomian sebum into the tear film by delivering latent heat to the eyelids, thus thickening the lipid layer. Normal lid movements are maintained, facilitating resurfacing of the tear film. METHOD: A prospective, controlled, observer masked, single intervention trial in which 24 normal subjects were randomised into three groups. Group I underwent 10 min treatment with the activated device, Group II used the inactivated device for the same duration of time, and Group III had no intervention. The LLT of each subject was measured with a Keeler Tearscope prior and subsequent to the 10-min period. Subjective alteration in ocular comfort was also assessed. RESULTS: Seven of eight subjects (87.5%) in Group I exhibited an increase in LLT. The mean LLT in this group showed a statistically significant increase (left eyes 1.0 levels, P<0.001, right eyes 0.9 levels, P<0.003) compared to Groups II and III. Six of eight subjects (75%) using the activated device experienced subjective improvement in ocular comfort. CONCLUSION: Meibomian therapy with this device increases LLT in normal individuals. This implies a more stable tear film, reflected in subjective improvement in ocular comfort.

Adult↗