Publications and source records attributed to G J Suh.

2 recordsLinked to original sources

Applications of the pulsatile flow versatile ECLS: in vivo studies.

INTRODUCTION: T-PLS (Twin-Pulse Life Support) is the first commercial pulsatile ECLS (Extra Corporeal Life Support) device (1). The dual sac structure of T-PLS can effectively reduce high membrane oxygenator inlet pressure and hemolysis. To verify both the use of T-PLS for ECLS and the advantages of T-PLS, we tested various models. METHOD AND RESULTS: In the partial CPB (cardio pulmonary bypass) model (swine), T-PLS (N = 6), and Biopump (N = 2), a single pulsatile pump (N = 2), were compared. In the case of single pulsatile flow, during pump systole, pressure increased to 700 - 800 mmHg at the inlet port of the membrane oxygenator. fHb, a hemolysis measurement value, was about 80 mg/dL at 3 hours. On the contrary, because of T-PLS's dual sac system, the pressure of T-PLS had a maximum value of about 250 mmHg and fHb was similar to that of the commercial centrifugal pumps. In the total CPB model (bovine, N = 6), the heart was stopped via cardioplegia (Kcl). T-PLS flow was maintained at 3.0-4.5 L/min. T-PLS functioned like a natural heart, having a pulse pressure of 26-43 mmHg and a pulse rate of 40-60 bpm (beats per minute). In the emergency case model (canine, N = 6), T-PLS was started 10 minutes after cardiac arrest from electronic shock. In spite of cardiac arrest for a period of 40 minutes, the heart was recovered after defibrillation. In the ARDS (Acute Respiratory Distress Syndrome) model (canine, N = 6), minimal ventilator parameters were set: tidal volume 130 ml, respiration rate = bpm, FiO2 = 10%. Three hours after starting T-PLS, PO2 of the carotid artery blood (after 2 hours: 195 +/- 89.4; after 3 hours: 258 +/- 99.3 mmHg) was above half the value of the femoral artery but was within normal range. CONCLUSION: It is suggested that a portable pulsatile ECLS like T-PLS may be used as a CPB device and as an alternative CPR (cardiopulmonary resuscitation) device in the case of cardiac arrest. Due to the pulsatile flow, oxygenated blood is delivered to the patient without overloading the ARDS patients heart.

Animals↗

Recombinant human growth hormone decreases lung and liver tissue lipid peroxidation and increases antioxidant activity after thermal injury in rats.

The combination of increased oxidant with decreased endogenous polypeptide and protein antioxidant activity corresponds to a decrease in cellular energetics and cell membrane lipid peroxidation. Providing large doses of growth hormone has been shown to preserve cell mass and organ function after burn injury. The role of growth hormone in oxidant injury has not been defined. We determined whether growth hormone altered the degree of lung and liver lipid peroxidation and the activity of glutathione and catalase in lung and liver tissue after burn injury. Four groups of 40 rats each were studied for 48 hours, with 1 group receiving a 20% full-thickness burn, 1 group treated with growth hormone after 20% full-thickness burn injury, a control group, and a growth hormone alone-treated group. We found increased lipid peroxidation, measured as malondialdehyde, in lung and liver tissue, and a decrease in glutathione and catalase activities during the 48-hour post-burn period. The addition of growth hormone prevented the lipid peroxidation and significantly increased tissue glutathione and catalase activities with respect to control values. Growth hormone alone also increased endogenous antioxidant levels. We conclude that growth hormone given after burn injury decreases oxidant stress by producing a significant increase in the endogenous antioxidants glutathione and catalase.

Analysis of Variance↗