PubMed Health⌕ Search

Biomedical subjects

G J Van Berkel

Publications and source records attributed to G J Van Berkel.

12 recordsLinked to original sources

Electrospray tandem mass spectrometric study of ferrocene carbamate ester derivatives of saturated primary, secondary and tertiary alcohols.

The fragmentation pathways and mechanisms for 27 ferrocene carbamate esters of saturated alkyl primary, secondary and tertiary alcohols were investigated using energy-resolved electrospray tandem mass spectrometry (ES-MS/MS). The mechanisms that control the formation and abundance of the three product ions common to all the derivatives, which appear at m/z 201, 227 and 245, were elucidated. Plotting the relative abundances of the three product ions versus a range of center-of-mass collision energies provided a graphical representation of the behavior of the fragmentation process that was directly comparable from compound to compound. As a result, it was possible to compare product ion spectra of the different derivatives to distinguish among different alcohol structural types. Straight-chain primary alcohols were easily distinguished from tertiary alcohols. Both of these structural types, including positional isomers, produced product ion spectra that were distinct from those of beta-branched primary alcohols, or acyclic secondary alcohols or cyclic secondary alcohols. The latter three alcohol types display similar product ion spectra and therefore cannot be distinguished from one another on the basis of these spectra alone.

Alcohols↗

Minimizing analyte electrolysis in an electrospray emitter.

The electrospray (ES) ion source is a controlled-current electrolytic flow cell. Electrolytic reactions in the ES emitter capillary are continually ongoing to sustain the production of charged droplets and ultimately gas-phase ions from this device. Under certain circumstances, the analytes under study may be directly involved in these electrolytic processes. It is demonstrated that a simple means to minimize analyte electrolysis is to exchange the normal metal emitter capillary of commercial ES sources with one made of fused silica. This change is shown to provide an ES mass spectrometric system of similar performance in terms of gas-phase ion signal generated for non-electroactive analytes and also assures minimal oxidation of electroactive analytes even at low (2.0 microl x min(-1)) solution flow-rates and high (millimolar) solution electrolyte concentrations.

Electrolysis↗

Redox buffering in an electrospray ion source using a copper capillary emitter.

An electrospray ion source used in electrospray mass spectrometry is a two-electrode, controlled-current electrochemical flow cell. Electrochemical reactions at the emitter electrode (oxidation and reduction in positive and negative ion modes respectively) provide the excess charge necessary for the quasi-continuous production of charged droplets and ultimately gas-phase ions with this device. We demonstrate here that a copper capillary emitter, in place of the more commonly used stainless-steel capillary emitter, can be utilized as a redox buffer in positive ion mode. Anodic corrosion of the copper capillary during normal operation liberates copper ions to solution and in so doing maintains the interfacial potential at this electrode near the equilibrium potential for the copper corrosion process [E degrees = 0.34 V versus standard hydrogen electrode (SHE)]. Fixing the interfacial potential at the emitter electrode provides control over the electrochemical reactions that take place at this electrode. It is shown that the oxidation of N-phenyl-1,4-phenylenediamine to N-phenyl-1,4-phenylenediimine (E(p/2) = 0.48 V versus SHE) can be completely avoided using the copper emitter, whereas this analyte is completely oxidized with a stainless-steel capillary emitter under the same conditions. Moreover, using N-phenyl-1,4-phenylenediimine, we demonstrate that reduction reactions can occur at the copper emitter electrode in positive ion mode. Emitter corrosion, in addition to redox buffering, provides a convenient means to introduce metal ions into solution for analytical use in electrospray mass spectrometry.

Journal Article↗

Electrospray tandem mass spectrometric study of alkyl 1-methylpyridinium ether derivatives of alcohols.

The fragmentation of 15 alkyl 1-methylpyridinium ether derivatives (D+) of primary and secondary alcohols, benzylic alcohols and phenyl-substituted alcohols was investigated using energy-resolved tandem mass spectrometry. Fragmentation pathways and mechanisms, including the influence of substituents, on the formation of the major product ions, which appear at m/z 110, [D - 109]+ and [D - 111]+, were postulated. Comparison of the abundances of these ions in the product ion spectra of isomeric alcohol derivatives, obtained at the same center-of-mass collision energy (2.0 eV), was found to provide the ability to differentiate among some isomers.

Journal Article↗

Electrochemical processes in a wire-in-a-capillary bulk-loaded, nano-electrospray emitter.

Experiments are described that illustrate solvent oxidation, emitter electrode corrosion, and analyte oxidation in positive ion mode nano-electrospray mass spectrometry using a wire-in-a-capillary, bulk-loaded nano-electrospray emitter geometry. Time-lapsed color photography of pH and metal specific indicator solutions within operating nano-electrospray emitters, as well as temporal changes in the ions observed in the nano-electrospray mass spectra, are used to probe these reactions, judge their magnitude, and study the time dependent changes in solution composition and gas-phase ion signal brought about as a result of these electrochemical reactions. The significance of these observations for analytical applications of nano-electrospray mass spectrometry are discussed.

Journal Article↗

Electrochemically modulated liquid chromatography coupled on-line with electrospray mass spectrometry.

Electrochemically modulated liquid chromatography (EMLC) has been coupled to an electrospray mass spectrometer. This combination takes advantage of the ability of EMLC to manipulate retention and enhance separation efficiency solely through changes in the potential applied to a conductive stationary phase, thereby minimizing complications because of possible changes in analyte ionization efficiencies when gradient elution techniques are used. Three examples are presented that demonstrate the attributes of this EMLC/electrospray mass spectrometry (ES-MS) coupling. The first two examples involve the separation of mixtures of corticosteroids or of benzodiazepines, showing the general utility of the union for eluent identification and low-level detection. The ability to identify products from on-column redox transformations is also demonstrated using the benzodiazepine mixture. The third example investigates the electrooxidation of aniline by utilizing an EMLC column as an on-line electrochemical reactor and product separator and ES-MS for detection and product identification.

Adrenal Cortex Hormones↗

Electrochemically modulated preconcentration and matrix elimination for organic analytes coupled on-line with electrospray mass spectrometry.

Demonstrated for the first time is the use of electrochemically modulated preconcentration and sample matrix elimination combined on-line with electrospray mass spectrometry (EMPM/ES-MS) for the enhanced analysis of organics by ES-MS. EMPM is similar to adsorptive stripping analysis. Accumulation of the targeted analytes at the working electrode of an on-line electrochemical flow cell is accomplished via a nonelectrolytic adsorption process that is controlled through the proper combination of the solvent system, the working electrode material, and applied potential. Once on the electrode, the analyte may be washed free of sample matrix components detrimental to mass spectrometric detection. The potential applied to the electrode during the detection step is chosen to release or strip the analytes unaltered back into the solvent stream for mass spectrometric detection rather than to oxidize or reduce them as would be the case for electrochemical detection. Thus, retention and elution of a target analyte with EMPM are controlled by switching the working electrode potential, rather than via a switch in mobile-phase composition, as is done in more traditional preconcentration and cleanup schemes used on-line with ES-MS. The proof-of-principle studies described here use the breast cancer drug tamoxifen and a metabolite, 4-hydroxytamoxifen, as the target analytes. A thin-layer, flow-by electrode cell with a glassy carbon working electrode is used as the preconcentration device. The nature of the working electrode, the solvent systems, and the electrode potentials necessary to accumulate and strip tamoxifen and 4-hydroxytamoxifen are discussed. Calibration curves were fitted using the Langmuir isotherm. Detection limits (DLs) using a 5.0 min preconcentration period with selected reaction monitoring for tamoxifen (m/z 372 --> 72) were bracketed as 0.010 nM < DL < 0.025 nM. The ability to simultaneously detect low nanomolar levels of both tamoxifen and 4-hydroxytamoxifen in pristine solution and 1/10 diluted urine is also demonstrated.

Electrochemistry↗

Electrolytic deposition of metals on to the high-voltage contact in an electrospray emitter: implications for gas-phase ion formation.

The electrospray ion source is an electrolytic flow cell. Electrolytic reactions in the electrospray emitter maintain the production of charged droplets by this ion source that contain an excess of ions of one polarity. These redox reactions necessarily change the composition of the solution that initially enters the emitter. As a result, the ions ultimately observed in the gas phase by electrospray mass spectrometry (ESMS) may be substantially influenced by both the nature and extent of these electrochemical reactions. It is demonstrated in this paper that Ag(+), Cu(2+) and Hg(2+) ions in solution can be electrolytically reduced and deposited as the respective metals on to the surface of the high-voltage contact in the electrospray emitter in negative ion mode electrospray. The deposited metals are shown to be liberated from the surface by switching the electrospray high-voltage polarity to operate in the positive ion mode. The deposited metals are oxidized in positive ion mode, releasing the metal ions back into solution where they are detected in the electrospray mass spectrum. In a semi-quantitative analysis, it was found that up to 50% of the Ag(+) in a 2.5 microM solution was deposited on the high-voltage contact of the emitter as the solution flowed through the emitter. Deposition of Cu(2+) and Hg(2+) was less efficient. These data illustrate that in the analysis of metals by ESMS, one must be aware that both the concentration and form of the metals may be altered by electrochemical processes in the emitter. Hence reduction or oxidation of metals in the electrospray emitter, which may remove ions from solution, or change metal valence, would be expected to impact both quantitative metal determinations and metal speciation attempts using ESMS.

Cations, Divalent↗

Ferrocene-based electroactive derivatizing reagents for the rapid selective screening of alcohols and phenols in natural product mixtures using electrospray-tandem mass spectrometry.

The alcohols and phenols of oil of cloves, lemon oil, rose absolut, and oil of peppermint were derivatized with ferroceneoyl azide to generate their ferroceneoyl carbamates. These derivatives are selectively detected at the attomole level, in nanomolar concentrations by electrospray-tandem mass spectrometry (ES-MS/MS) without the need for sample cleanup. The ES-MS/MS analyses of the four essential oils revealed all the expected alcohols, and, in the case of lemon oil, it detected alpha-terpineol as a trace component that was not readily observed by GC-MS. The ES-MS/MS analyses complements the more conventional GC-MS analysis. The ES-MS method has the advantage of speed, selectivity, and sensitivity over GC-MS for detection of a targeted alcohol of a specific mass or structural type. The ES-MS method does not require a chromatographic separation of the components to accomplish its task. In contrast, GC-MS remains the preferred method for the determination of the total constituents of an oil. The ES-MS method may produce artifact ions, especially if the sample is wet and an excess of the ferroceneoyl azide is used; however, the artifacts did not interfere with the analyses.

Alcohols↗

Derivatization for electrospray ionization mass spectrometry. 3. Electrochemically ionizable derivatives.

In this paper, the use of ferrocene-based "electrochemically ionizable" derivatives to enhance ES-MS analysis of simple alcohols, sterols, and phenols is discussed. These derivatives are designed to take advantage of the electrolysis process inherent to operation of the ES ion source for selective ionization. Derivatization procedures, electrochemical character of the derivatives, and the ES-MS operational parameters necessary to maximize electrochemical ionization and to enhance gas-phase detection are presented with reference to ferrocenecarbamate ester derivatives of a variety of alcohol standards, as well as the ferroceneboronate derivative of the diol, pinacol. Tandem mass spectrometric analysis of the derivatives (precursor and product ion spectra) is shown to provide derivative confirmation, enhanced detection, and additional analyte structure information. The utility of this derivatization approach for the selective detection of alcohols in complicated mixtures is demonstrated using a saw palmetto (Serenoa repens) fruit extract known to contain a variety of alcohols at low levels.

Alcohols↗

Ion trap mass spectrometry. Using high-pressure ionization.

The quadrupole ion trap, operated with a relatively high-pressure bath gas, occupies a unique place among mass analyzers. As an ion storage device, it shares many characteristics with the ICR instrument, but the use of a light bath gas and mass-selective instability for mass analysis contrasts with normal ICR operation. The bath gas facilitates the capture of ions injected into the oscillating quadrupole field and cools the ions to the center of the ion trap before mass-selective ejection. The bath gas also provides a conduit for heating ions. Mild collisional activation conditions can dissociate clusters, such as solvated analyte ions, formed by ES. Dissociation of covalently bound ions can be used to obtain structural information as part of a tandem MS experiment or to destroy polyatomic species in elemental analyses. The moderate background pressure requirements of the ion trap using mass-selective instability make it a natural mass analyzer to be coupled with high-pressure ionization methods. The ion trap can provide a significant advantage in efficiency over beam-type mass spectrometers, which translates into lower detection limits. Lower detection limits can be realized from superior duty cycle and MS/MS efficiency, although transmission for single-stage MS is comparable. The greatest advantage in efficiency can be obtained with weak ion beams that require long ion accumulation times and therefore high duty cycles. This, in part, makes the ion trap particularly attractive for ES. Bright ion sources can provide similar advantages if major ion beam components can be ejected during ion accumulation to minimize the deleterious effects caused by ion-ion interactions.(ABSTRACT TRUNCATED AT 250 WORDS)

Mass Spectrometry↗

Charge determination of product ions formed from collision-induced dissociation of multiply protonated molecules via ion/molecule reactions.

The use of ion/molecule reactions involving multiply protonated ions derived from electrospray for the determination of the charges of product ions formed from collision-induced dissociation is described. The experiments are carried out with a quadrupole ion trap capable of multiple stages of mass spectrometry. The approach is illustrated with proton transfer from a product ion from quadruply protonated melittin, and from a product ion from the (M + 20H)20+ ion from horse myoglobin, to 1,6-diaminohexane. The major product ion from quadruply protonated bovine insulin is used to illustrate the use of a clustering reaction with 1,6-diaminohexane. The ion trap is shown to be a particularly useful tool for employing both collisional activation and low-energy ion/molecule reactions in the same experiment to determine product ion charge.

Animals↗