PubMed Health⌕ Search

Biomedical subjects

G Jeronimidis

Publications and source records attributed to G Jeronimidis.

7 recordsLinked to original sources

The effects of mass loading the ossicles with a floating mass transducer on middle ear transfer function.

HYPOTHESIS: The aim of this study was to measure the mass loading effect of an active middle-ear implant (the Vibrant Soundbridge) in cadaver temporal bones. BACKGROUND: Implantable middle ear hearing devices such as Vibrant Soundbridge have been used as an alternative to conventional hearing aids for the rehabilitation of sensorineural hearing loss. Other than the obvious disadvantage of requiring implantation middle ear surgery, it also applies a direct weight on the ossicular chain which, in turn, may have an impact on residual hearing. Previous studies have shown that applying a mass directly on the ossicular chain has a damping effect on its response to sound. However, little has been done to investigate the magnitude and the frequency characteristics of the mass loading effect in devices such as the Vibrant Soundbridge. METHODS: Five fresh cadaver temporal bones were used. The stapes displacement was measured using laser Doppler vibrometry before and after the placement of a Vibrant Soundbridge floating mass transducer. The effects of mass and attachment site were compared with the unloaded response. Measurements were obtained at frequencies between 0.1 and 10 kHz and at acoustic input levels of 100 dB sound pressure level. Each temporal bone acted as its own control. RESULTS: Placement of the floating mass transducer caused a reduction of the stapes displacement. There were variations between the bones. The change of the stapes displacement varied from 0 dB to 28 dB. The effect was more prominent at frequencies above 1,000 Hz. Placing the floating mass transducer close to the incudostapedial joint reduced the mass loading effect. CONCLUSION: The floating mass transducer produces a measurable reduction of the stapes displacement in the temporal bone model. The effect is more prominent at high frequencies.

Acoustic Stimulation↗

Variations in the morphology of wood structure can explain why hardwood species of similar density have very different resistances to impact and compressive loading.

A clear relationship has been established between the impact resistance and density of softwoods. However, there are hardwood species that have the same density but very different impact resistance. Softwoods are largely composed of tracheid cells (30-50 microm across); hardwoods have smaller fibre cells and also contain vessels (50-500 microm across). We examined white oak, beech, hickory and spruce. Compressive deformation was identified as the main mechanism for energy absorption in the type of impact test used. The disparate size of different wood cells in the hardwoods results in heterogeneous compressive deformation. During compression, large vessels cause smaller surrounding cells to be deformed more than in regions without vessels, increasing the energy absorbed. However, vessels that are too close together initiate kink banding at low loads and less energy is absorbed. The different morphologies of hardwoods are probably responsible for the variation in impact resistance between species of similar density. Drilling small holes along the grain of spruce, which naturally lacks vessels, mimicked the effect of vessels and did not reduce the energy-absorbing capabilities of the wood, despite the density being reduced. These findings could be used to increase the energy-absorbing capacity of synthetic foam materials.

Absorption↗

A novel strain sensor based on the campaniform sensillum of insects.

The functional design of the campaniform sensillum was modelled as a hole in a plate using two- and three-dimensional finite-element modelling. Different shapes of opening in a fibrous composite plate amplify differently the global strains imposed on the plate, and different configurations of reinforcement also have an effect. In this paper, the main objective is to study the strain and displacement fields associated with circular or elliptical openings in laminated plates in order to investigate their potential for integrated strain sensors. Since we are therefore primarily interested with the detection of displacement, the detailed stress concentration levels associated with these openings are not of primary concern. However, strain energy density levels associated with different hole and fibre configurations have been used to assess the relative likely strength reduction effect of the openings. To compare the relative strain amplification effect of drilled and formed holes of the same size in loaded plates, we have used the relative change in length of diameters (circular) or semi-axes (elliptical) in directions parallel and normal to the load. Various techniques which could sense this deformation were investigated, in particular, the coupling mechanism of a campaniform sensillum of Calliphora vicina. This mechanism was resolved into discrete components: a cap surrounded by a collar, a joint membrane and an annulus-shaped socket septum with a spongy compliant zone. The coupling mechanism is a mechanical linkage which transforms the stimulus into two deformations in different directions: monoaxial transverse compression of the dendritic tip and vertical displacement of the cap. The mechanism is insensitive to change of the material properties of the socket septum, the cuticular cap and the spongy cuticle. The joint membrane may serve as a gap filler. The material properties of the collar have a substantial influence on the coupling mechanism's output. A 30% change of stiffness of the collar causes 45% change in the output of the coupling mechanism. The collar may be able to tune the sensitivity of the sensillum by changing its elastic properties.

Animals↗

Heat transfer through penguin feathers

Morphological measurements of penguin feathers are used to construct a thermal model of heat transfer through the coat. Assuming uniform distribution of the feathers and their associated afterfeathers, it is possible to model heat transfer through the coat of the penguin using standard theory. It is shown that convection does not occur in the coat of the penguin and that radiative heat loss is minimized. The theory predicts a thermal conductivity of 2.38 W m(-2)K(-1)which compares well with an empirically measured value of 1.93 W m(-2)K(-1). Copyright 1999 Academic Press.

Journal Article↗

Preliminary investigation of a novel controlled stiffness proximal femoral prosthesis.

Previous studies have suggested that a controlled stiffness prosthesis is required to address the conflicting requirements of minimizing stress shielding and micromotion. The design for a controlled stiffness prosthesis is proposed and a preliminary analytical investigation performed to assess its predicted performance before fabrication of a prototype component. The novel prosthesis consisted of a cobalt-chrome core and a flexible composite outer layer. Varying the composite layer thickness allowed the prosthesis stiffness to be controlled. Three variants of the controlled stiffness prosthesis were critically assessed using the finite element method and their predicted performance compared with those of conventional prosthesis designs. The potential for stress shielding was assessed by examining the periosteal strain energy and the potential for migration assessed by examining the endosteal minimum principal cancellous bone stresses. Both the conventional and controlled stiffness implants performed poorly as press-fit prostheses. All the press-fit prostheses generated high cancellous bone stresses, suggesting that excessive migration of these implants would be likely. The controlled stiffness implants performed better than the conventional implants when bonded to the surrounding bone. Although the controlled stiffness implants did not eliminate stress shielding of the calcar, they produced higher strain energies than the conventional designs. The findings of this study are that osseointegrated controlled stiffness implants may perform better than current osseointegrated cementless prostheses and therefore it is worth while progressing to the next stage, of prototyping an implant.

Biocompatible Materials↗