An electromyographic study of whether the digastric muscles are controlled by jaw-closing proprioceptors in man.

Whether in the oral system the digastric muscles (which lack muscle spindles) are under the control of proprioceptive information from the masseter muscles (which contain muscle spindles) was investigated by analysing whether and how the masseters and digastrics showed coordinated behaviour during a static, forceful bite. Subjects were asked to maintain a 100-N force for 15 s with and without visual guidance; bite force exerted, and masseter and digastric electromyograms (EMGs) were recorded. Under visual guidance all subjects co-contracted their digastric muscles during the isometric bite. They held the force for a short time, followed by periods with fluctuations (peak-to-peak force amplitude about 15-20 N). Fluctuations in bite force correlated with the masseter EMGs, the maximum in the correlogram occurring at about -50 ms with the force lagging the masseter. In 75% of the subjects a significant periodic component in the masseter and in the force spectra was found at about 4 Hz. This was also seen in the amplitude spectra of the forces, which showed in 80% of the subjects a significant elevation between 7-10 Hz as well. No correlation between the digastric EMGs and the bite forces, and between the EMGs of masseter and digastric could be detected. Spectra of digastric EMGs showed no prominent maxima. When subjects were deprived of visual feedback, maxima at -50 ms in the cross-correlation functions of the masseters and the forces were reduced considerably; periodicities of +/- 250 ms disappeared.(ABSTRACT TRUNCATED AT 250 WORDS)

Bite Force↗

Minimum procedures for visual electrodiagnostic testing.

A set of procedures for the electroretinogram, electrooculogram, and pattern and luminance visual evoked cortical potentials was defined by representatives from all Dutch University Eye Clinics in order to promote standardization of procedures for routine diagnostic testing. The procedures have been selected to obtain an answer to most electrodiagnostic questions of frequent occurrence with a minimum of equipment and examination time. An individual examiner may add other procedures to the proposed program to extend and diagnostic possibilities.

Electrodiagnosis↗

Neural conduction time and steady-state evoked potentials.

Signal processing in neural networks will inevitably include delays due to the finite conduction velocity of the neurones and their interconnections. Diamond proposed a method for finding these delays in the case of (visual) steady-state responses. Alignment of response features, when represented in a time domain plot, would, allegedly, yield the delay. We show that filter action, by introducing frequency-dependent phase shifts, is bound to distort the time domain plot considerably, thereby aligning the response features in such a way that a wrong value for the delay is found. This makes that analysis method of doubtful significance.

Evoked Potentials, Visual↗

The visual electrically evoked potential (VEEP): steady-state responses.

The steady-state response of the visual system may provide us with complementary information about the system, when compared with transient EPs (Regan 1977). With our setup we could record such steady-state responses to electrical stimulation of the visual system for frequencies higher than about 20 Hz. We found comparatively little decline in amplitude with increasing frequency. We conclude that not much filtering is done by the system under study. The absence of pseudoflash related potentials substantiates this conclusion. Therefore it is likely that there is a constant latency for the frequencies under consideration. We also found that after some 10 cycles of the stimulating alternating current the steady-state seemed to be established. This indicates that by introducing silent periods after a limited number of stimulus cycles, recording during these periods and applying the analysis method of Diamond, the latency of the visual electrically evoked steady-state response can be determined.

Electroencephalography↗

Recording the visual electrically evoked potential (VEEP).

A system for recording cortical responses to electrical stimulation of the visual system (electrical phosphene) is described. The system included a rotatable electrode pair for stimulation, with which artifacts caused by the relatively large stimulating currents could be reduced to suitable levels. Optical isolation on both the stimulating and recording sides of the equipment provided safety for the subject and made precise application of the stimulating current possible.