PubMed Health⌕ Search

Biomedical subjects

G K Bonn

Publications and source records attributed to G K Bonn.

29 records · Page 2Linked to original sources

Capillary zone electrophoresis and micellar electrokinetic chromatography of 4-aminobenzonitrile carbohydrate derivatives.

Aldoses, ketoses and uronic acids were derivatized successfully within 15 min at a temperature of 90 degrees C by reductive amination with 4-aminobenzonitrile. Subsequently, the derivatives were separated as their borate complexes by capillary zone electrophoresis, using 175 mM borate buffer, pH 10.5, as carrier. The electrophoretic mobilities were determined by the complex stability, which was found to depend on the number of hydroxyl groups on any given carbohydrate derivative, the presence of substituents, and most strongly on the configuration of the vicinal hydroxyl groups at C-3 and C-4 in aldoses and uronic acids, and with regard to ketoses on those at C-4 and C-5. Time of analysis could be reduced considerably by the use of micellar electrokinetic chromatography, which separated 4-aminobenzonitrile sugar derivatives on the basis of their differential partitioning into an electroendosmotically driven aqueous phase and into sodium dodecyl sulfate micelles. Optimum resolution was achieved with a Tris-phosphate buffer, pH 7.5, containing 100 mM of sodium dodecyl sulfate. The method made it possible to resolve several carbohydrates which had not been resolved successfully by means of capillary zone electrophoresis, such as glucose and fructose. Moreover, separation selectivity could be adjusted by varying the capillary temperature. Finally, on-column UV monitoring at 285 nm allowed the detection of glucose with a lower mass detection limit of 1 fmol and a concentration sensitivity of 0.3 microM.

Borates↗

High-performance liquid chromatography for routine analysis of hepatitis C virus cDNA/PCR products.

Ion-pair reversed-phase high-performance liquid chromatography on alkylated nonporous polystyrene-divinylbenzene particles with a mean diameter of 2.1 microns was used to analyze PCR products according to their chain length within a few minutes. The simple and reliable procedure allows the simultaneous separation and isolation of DNA fragments differing in chain length by 1%-5% up to a size of 500 base pairs with recovery rates exceeding 97%. A greater than 70-fold increase in sensitivity could be achieved through the use of a fluorescein-labeled primer, which allowed the determination of a 127-bp hepatitis C virus cDNA/PCR product with a lower mass detection limit of 2 fmol. Calibration curves showed excellent linearity over a range of at least 4 magnitudes. Finally, the stationary phase allowed the routine analysis of hundreds of PCR products with high reproducibility of both retention times and peak areas.

Base Sequence↗

High-resolution liquid chromatography of oligonucleotides on nonporous alkylated styrene-divinylbenzene copolymers.

Phosphodiester-oligonucleotides were separated by ion-pair reversed-phase HPLC on nonporous polystyrene-based particles having a diameter of 2.1 +/- 0.12 microns. With unmodified poly(styrene-divinylbenzene) beads it was not possible to resolve oligonucleotides efficiently. However, upon addition of polyvinyl alcohol during polymerization baseline resolution of phosphorylated oligodeoxyadenylic acids with a chain length of up to 30 bases was obtained, with triethylammonium acetate serving as ion-pairing reagent. An even higher separation efficiency was achieved by Friedel-Crafts alkylation of poly(styrene-divinylbenzene) particles. At a column temperature of 50 degrees C, the number of theoretical plates exceeded 6 x 10(5) per meter. The maximum loading capacity for a 50 x 4.6-mm i.d. column still resulting in the highest resolution was 0.1 microgram. Calibration curves showed excellent linearity over a range of at least 4 magnitudes, with a lower mass detection limit of 0.16 ng. Recoveries ranged from 96.7 to 100.8%. The same stationary phase also allowed the separation of phosphorylated from dephosphorylated oligonucleotides, the former ones being eluted earlier.

Alkylation↗

High-resolution liquid chromatography of DNA fragments on non-porous poly(styrene-divinylbenzene) particles.

DNA restriction fragments and PCR products were separated by means of ion-pair reversed-phase high-performance liquid chromatography on alkylated non-porous poly(styrene-divinylbenzene) particles with a mean diameter of 2.1 microns. Optimum resolution was obtained by using an acetonitrile gradient in 100 mM of triethylammonium acetate and a column temperature of 50 degrees C. This allowed the separation of DNA fragments differing in chain length by 1-5% up to a size of 500 base pairs. PCR products could be analyzed directly in less than two minutes with a concentration sensitivity of at least 300 ng/ml. Compared with anion-exchange chromatography or gel electrophoresis no desaltation of the purified DNA molecules is required because the volatile buffer system can be readily evaporated. Subsequently, the method was used for the semiquantitative evaluation of the expression of multidrug resistance genes in mononuclear white blood cells.

Base Sequence↗

Comparative study of capillary zone electrophoresis and high-performance liquid chromatography in the analysis of oligonucleotides and DNA.

Capillary zone electrophoresis and high-performance liquid chromatography were compared with regard to the separation of oligonucleotides and double-stranded DNA. Both anion-exchange and reversed-phase high-performance liquid chromatography on non-porous particles are considered to be superior to capillary electrophoresis in terms of speed and selectivity in the analysis of oligonucleotides up to 30 bases in length. Moreover, reversed-phase chromatography allows the simultaneous purification of detritylated oligonucleotides with recoveries > 90%. Compared with anion-exchange chromatography, there is no need for a subsequent desaltation step because the volatile buffer system can be readily evaporated. With regard to dsDNA, however, the resolving power of capillary electrophoresis cannot be matched by anion-exchange chromatography at present. Moreover, the combined use of hydroxyethylcellulose and ethidium bromide not only yielded a separation efficiency equal to that achieved by means of gel-filled capillaries but also avoids some of their limitations such as the destruction of the gel matrix at high current densities and the bias involved in electrokinetic injection.

Base Sequence↗

High-performance liquid chromatographic separation of detritylated oligonucleotides on highly cross-linked poly-(styrene-divinylbenzene) particles.

Detritylated oligonucleotides were separated by reversed-phase high-performance liquid chromatography on highly cross-linked polystyrene-based particles having a mean particle diameter of 2.3 microns. The addition of poly(vinyl alcohol) during polymerization, which resulted in the presence of hydroxyl groups on the surface of the poly(styrene-divinylbenzene) beads, was necessary to obtain baseline resolution of phosphorylated oligodeoxyadenylic acids with a chain length of up to 30 bases. The impact of temperature was investigated and optimum resolution was achieved at 40 degrees C. At pH 7.0, the retention times of oligonucleotides were found to depend on the ratio of bases and to increase in the order of C less than G less than A less than T. Under the same conditions, it was possible to separate phosphorylated from dephosphorylated oligonucleotides, the former being eluted earlier. Recoveries ranged from 92 to 100%.

Base Sequence↗

Thin-layer electrophoresis of hydroxyethyl starches on a modified silica gel support.

The recent developed thin-layer electrophoresis on modified silanized silica gel was applied to the separation of hydroxyethyl starches (HES) and glycogen and of HES with different degrees of substitution. This method permits a rapid qualitative and semi-quantitative determination of HES in animal tissues such as liver, lung, heart and kidney after their disintegration with alkali and precipitation with ethanol.

Animals↗

[Analysis of polycyclic aromatic hydrocarbons in lipid-containing biological matrices--study of contamination of breast milk by benzo(a)pyrene along transit routes through Tyrol].

41 samples of human milk from the region of Tyrol were investigated with regard to benzo(a)pyrene content. A complicated analytical preparatory method had to be worked out. The percentage recovery of benzo(a)pyrene was 85-90. Analysis was carried out by means of capillary gas chromatography and flame ionization detection or mass spectrometry. The limit of benzo(a)pyrene detection is 0.1-1 microgram/kg (single ion monitoring). None of the investigated samples of milk showed the presence of benzo(a)pyrene.

Air Pollutants↗

High-resolution capillary electrophoretic analysis of DNA in free solution.

Capillary electrophoretic separations of double-stranded DNA fragments in the size range of 20-2200 base pairs were achieved in less than 20 min with the use of a Tris-borate buffer containing hydroxyethylcellulose. Analyses were carried out in both uncoated and phenylmethyl-coated capillaries of fused silica with internal diameters of 50 and 100 microns, respectively, and an effective column length of 50 cm. The addition of ethidium bromide resulted in an improved resolution of double-stranded DNA fragments, thereby permitting even the separation of fragments differing only 1-2 base pairs in length. Moreover, resolution was found to be linearly proportional to the size of the cation used to adjust ionic strength Cs+ greater than RB+ greater than K+ greater than Na+ greater than Li+. However, the analysis times also increased with increasing cation size due to a decrease in electroosmotic flow. Elution order was verified by spiking restriction digests with slab gel electrophoretically purified components. Subsequently, the described system was applied to the detection and quantitation of an mRNA transcript of the androgen receptor, which had been amplified by polymerase chain reaction and purified by size-exclusion chromatography to avoid peak broadening due to conductivity differences between sample and running buffer. Since the actual amount of DNA introduced into the capillary cannot be defined, molar ratio-peak area ratios of the polymerase chain reaction product to various restriction fragments of known concentration were used to determine the amount of amplified DNA. The coefficient of variation was as small as 3.4% and the results were in good agreement with a spectrophotometric assay.

Base Sequence↗

Capillary electrophoretic analysis of flavonoids.

Combining the effects of electrophoresis and electroendosmosis, flavonoids were separated in less than ten minutes in a fused silica capillary tube with a borate buffer adjusted to pH 10. An increase in the concentration of borate from 0.1 to 0.2 M resulted in longer migration times due to a decrease in electroosmotic flow, but also in improved selectivity and higher resolution of flavonoids. The calibration curve of rutin showed a detection limit of 0.02 mg/mL and linearity over its pharmaceutical concentration range. Using an internal standard of known concentration, the content of rutin in a methanolic extract of Sambuci flos could be determined with a coefficient of variation as small as 3.8% by the molar ratio-peak area ratio method.

Boric Acids↗

Evaluation of detection methods for the reversed-phase HPLC determination of 3',4',5'-trimethoxyflavone in different phytopharmaceutical products and in human serum.

Quantitative determination of the major compound, 3',4',5'-trimethoxyflavone (1), in plant extracts, in tablets of Flos and of Radix Primulae veris and in human serum has been accomplished using reversed-phase HPLC with UV, fluorescence and mass spectrometric (MS) detection. Compared to UV detection, fluorescence detection showed greater selectivity, was 10-fold more sensitive and allowed the determination of 1 in human serum after sample pre-treatment by solid-phase extraction. MS detection of 1 using electrospray ionisation (ESI) interface could be improved by substituting trifluoroacetic acid with the more polar and less conductive additive acetic acid, giving rise to a 230-fold improvement in analyte detectability at the cost of an increase of only 45% in the peak width of the eluting peak at its half height. Further optimisation of the acetic acid concentration showed the highest signal intensity at 1.25% for HPLC-atmospheric pressure chemical ionisation (APCI)-MS and at 0.75% for HPLC-ESI-MS. The optimised MS method proved to be extremely selective, 50 times more sensitive than UV detection and 5 times more sensitive than fluorescence detection. Furthermore, fragment-ion spectra produced by collision induced dissociation-MS have been used as "fingerprints" for identifying compounds in the highly complex mixtures examine.

Chromatography, High Pressure Liquid↗