PubMed Health⌕ Search

Biomedical subjects

G K Lang

Publications and source records attributed to G K Lang.

At least 19 recordsLinked to original sources

[Comparison of Preferential Hyperacuity Perimeter (PHP) test and Amsler grid test in the diagnosis of different stages of age-related macular degeneration].

BACKGROUND: Age-related macular degeneration (ARMD) is the leading cause of blindness in people over 65 years of age. A rapid loss of vision occurs especially in cases with choroidal neovascularisation. Early detection of ARMD and timely treatment are mandatory. We have prospectively studied the results of two diagnostic self tests for the early detection of metamorphopsia and scotoma, the PHP test and the Amsler grid test, in different stages of ARMD. PATIENTS AND METHODS: Patients with ARMD and best corrected visual acuity of 6/30 or better (Snellen charts) were examined with a standardised protocol, including supervised Amsler grid examination and PHP, a new device for metamorphopsia or scotoma measurement, based on the hyperacuity phenomenon in the central 14 degrees of the visual field. The stages of ARMD were independently graded in a masked fashion by stereoscopic ophthalmoscopy, stereoscopic fundus colour photographs, fluorescein angiography, and OCT. The patients were subdivided into 3 non-neovascular groups [early, late (RPE atrophy > 175 microm) and geographic atrophy], a neovascular group (classic and occult CNV) and an age-matched control group (healthy volunteers). RESULTS: 140 patients, with ages ranging from 50 to 90 years (median 68 years), were included in the study. Best corrected visual acuity ranged from 6/30 to 6/6 with a median of 6/12. 95 patients were diagnosed as non-neovascular ARMD. Thirty eyes had early ARMD (9 were tested positive by the PHP test and 9 by the Amsler grid test), and 50 late ARMD (positive: PHP test 23, Amsler grid test 26). The group with geographic atrophy consisted of 15 eyes (positive: PHP test 13, Amsler grid test 10). Forty-five patients presented with neovascular ARMD (positive: PHP test 38, Amsler grid test 36), 34 volunteers served as control group (positive: PHP test 1, Amsler grid test 5). CONCLUSIONS: The PHP and Amsler grid tests revealed comparable results detecting metamorphopsia and scotoma in early ARMD (30 vs. 30 %) and late ARMD (46 vs. 52 %). However, the PHP test more often revealed disease-related functional changes in the groups of geographic atrophy (87 vs. 67 %) and neovascular ARMD (84 vs. 80 %). This implies that the PHP and Amsler grid self tests are useful tools for detection of ARMD and that the PHP test has a greater sensitivity in the groups of geographic atrophy and neovascular AMD.

Aged↗

[Retinal angiomatous proliferation in age-related macular degeneration].

BACKGROUND: Angiomatous proliferation in ARMD originates from the retina and extends into the subretinal space. Retinal angiomatous proliferation (RAP) is diagnosed with angiography. This study investigates the characteristics of RAP in optical coherence tomography (OCT) and correlates them with clinical and fluorescein angiographic findings. METHODS: 327 consecutive patients with age-related macular degeneration (ARMD) were retrospectively examined using a standardised protocol. The protocol included best corrected visual acuity (BCVA), binocular ophthalmoscopy, fundus photography, fluorescein angiography (FAG) and OCT. The OCT and angiographic findings were graded in 3 RAP stages. RESULTS: 32 of 327 (9.79 %) patients (45 eyes) had RAP. The age ranged from 56 to 90 years (median: 79 years). 9 eyes presented RAP stage I, 23 stage II and 13 stage III. BCVA ranged from 0.01 to 0.7 (median: 0.2). OCT foveal minimum was 136 to 722 microns (median: 327). 33 (73 %) eyes showed a detachment of retinal pigment epithelium (RPE). Macular oedema was found in 43 (96 %) eyes. Cystoid macular oedema was seen in 36 (80 %) eyes. In stage II, 22 eyes (96 %) showed an RPE detachment, in stage III 11 eyes (85 %). 11 (85 %) eyes in stage III showed retinal-choroidal anastomosis. CONCLUSIONS: RAP was found in 9.79 % of the patients with ARMD. The OCT is helpful in detection of RPE detachment, macular oedema and cystoid changes in RAP. RAP and retinal-choroidal anastomosis should be identified because of the possibly poor prognosis.

Aged↗

[Corneal wound healing after experimental penetrating keratoplasty after excimer laser trephination in free form].

BACKGROUND: The postoperative clinical course after penetrating keratoplasty and trephination in free form using a guided excimer laser beam has been published before. Here the findings of light-microscopy comparing corneal wound healing after experimental penetrating keratoplasty after laser trephination and after conventional mechanical trephination are presented. MATERIALS AND METHODS: Homologous penetrating keratoplasty was performed on 12 NZW rabbits (6 animals with mechanical trephination, 6 animals with excimer laser trephination). The cutting edges achieved by both trephination techniques were examined by light microscopy in the remaining donor rings. During the postoperative follow-up animals were sacrificed at 3 and 6 weeks and at 3 months. Corneal specimens were retrieved and corneal healing processes were evaluated by light microscopy. RESULTS: The cutting edges of corneal excisions with the excimer laser demonstrated a high precision with only minimal collateral damage to adjacent tissue structures. At the different intervals both trephination groups demonstrated comparable stages of corneal wound healing regarding epithelial regeneration, stromal fibroblast migration with collagen synthesis and Descemet repair by endothelial synthesis of basement membrane. After 6 months corneal specimens of both groups demonstrated complete healing with nearly parallel orientation of newly synthesised collagen lamellae. Corneal thickness in the wound areas did not differ significantly from normal corneal tissue. CONCLUSIONS: Experimental follow-up studies to evaluate the feasibility of the developed technology of laser trephination in the living eye have shown no differences between conventional mechanical and excimer laser trephination with a guided beam. The present histology study also does not demonstrate any significant differences in corneal wound healing between the two trephination groups. Although excimer laser trephination along metal masks has now been established for several years, the here presented technique for trephination with individualised transplant geometries appears to be a valuable addition to the surgical repertoire in the presence of selected corneal pathologies.

Animals↗

[The different opacity patterns of Lisch corneal dystrophy].

BACKGROUND: Lisch corneal dystrophy is an epithelial corneal dystrophy where diffuse gray corneal opacifications are seen in direct illumination that appear in different patterns. Examination in retroillumination shows that these gray changes do consist of multiple densely crowded clear microcysts according to the opacity units. We wanted to investigate if one single case of Lisch corneal dystrophy can be differentiated easily from the other epithelial corneal dystrophies by exact analysis of the opacity units. PATIENTS AND METHODS: We examined three non-related patients with Lisch corneal dystrophy at the slit-lamp. The epithelial corneal opacities were documented photographically with direct slit-lamp illumination and retroillumination. RESULTS: All three patients showed the characteristic intraepithelial densely crowded clear microcysts in retroillumination. Diffuse gray radial opacities were noted in both corneas of a 15-year-old female patient. A club-shaped opacity was noted in one cornea of a 35-year-old female patient and a feathery gray opacity pattern was found in one cornea of a 49-year-old male patient. All three patients showed the characteristic densely crowded clear microcysts of Lisch corneal dystrophy in retroillumination. CONCLUSION: Taking the previous literature into account, five different opacity patterns can be summarised: radial, band, flame/feathery, whorled and club-shaped gray epithelial corneal opacities. A single case of Lisch corneal dystrophy can be differentiated from other epithelial corneal dystrophies by means of an exact analysis of the opacity pattern and units by slit-lamp examination.

Adolescent↗

[Refractive aspects of modern cataract surgery].

OBJECTIVE: Modern cataract surgery is a refractive procedure whereby one basically can achieve the targeted postoperative refraction. METHODS: To achieve this goal, according to the patient's wishes, biometry, mathematical calculation of IOL power and astigmatism management are important factors. On the other hand, multifarious developments in intraocular lens technology also contribute to this target. RESULTS: The individual choice of incision (on axis surgery: incision in the steeper meridian, length, shape and location concerning cornea or sclera) reduces the preoperatively existing astigmatism. Biometry with personalised data and formulas of the third generation are important factors to achieve the targeted refraction. In addition to this, the development of manifold lens designs in the last years to improve intraocular lens quality has enabled progress within various domains, for example, the use of optimised intraocular lenses to compensate corneal aberration, the implantation of toric lenses for corrections of higher pre-existing corneal astigmatism or the use of phacic intraocular lenses to correct higher ametropia. CONCLUSION: Patient satisfaction postoperatively depends on the precise refractive result as desired. With our current operative and technical possibilities we are able to achieve this with high probability and safety.

Astigmatism↗

[In-vitro comparison of morphology of current microkeratomes for LASIK].

BACKGROUND: We have performed an in-vitro examination of the morphology of flap thickness and stromal bed after LASIK in porcine eyes. MATERIALS AND METHODS: Freshly enucleated porcine eyes and synthetic eye models were used for cutting flaps with the microkeratomes Hansatome-Excellus (Bausch&Lomb), M2 single use (Moria), Amadeus (AMO), MK-2000 (Nidek) and Carriazo-Pendular (Schwind). The flap thickness of porcine eyes was determined using a non-contact, confocal optical distance measuring device (CHR 150N, Jurca), in the eye models a mechanical thickness measuring device (Käfler) was used. The morphology of the stromal bed was examined by photography, histology, scanning electron microscopy and confocal optical distance measurements. RESULTS: The optical/mechanical flap thickness measurements showed an average difference compared to the adjusted thickness of - 3/+ 90 microm (Hansatome-Excellus), + 7/+ 100 microm (M2 single use), - 35/+ 40 microm (Amadeus), - 4/+ 80 microm (MK-2000) and + 11/+ 0 microm (Carriazo-Pendular). Histology showed no mechanical damage and smooth, slightly undulating surfaces with all microkeratomes. In the scanning electron microscopic examination, the stromal surface was found to be homogeneous and smooth for all of the microkeratomes. Average roughness of the ablation surface was 0.27 microm (Hansatome-Excellus), 0.23 microm (M2 single use), 0.21 microm (Amadeus), 0.23 microm (MK-2000) and 0.29 microm (Carriazo-Pendular). CONCLUSION: The stromal bed showed in all cases only a slightly roughness, which seems to be acceptable for the clinical outcome. However, the more critical point is the large variations in flap thickness compared to the intended thickness.

Animals↗

[Does the orientation of the IOL in the eye play a role? Imaging quality of foldable intraocular lenses measured utilizing point spread function (PSF-measurement) and scanning electron microscopy cross-sectional images].

BACKGROUND: Foldable intraocular lenses (IOLs) are established in ophthalmic surgery and increasingly more complex geometries are available. This study investigates different designs of the optics of the IOL as well as the imaging quality of these optics utilizing electron microscopic photographs and mathematical approximations. METHOD: Included in this study were two different lens powers of common IOLs (+ 13 D and + 26 D). All studied IOLs were processed depending upon their water content: Aqueous IOLs with up to 25 % water content were fixed with 2.5 % glutaraldehyde in 0.1 M phosphate buffer (mPP), and then contrasted with 2 % OsO (4) and processed in an alcohol series of 30 - 100 % propanol. Subsequently, the IOLs were transferred into EPON (epoxy resin) and polymerization took place at 60 degrees C. After hardening, the samples were cut out with a leaves saw and divided into halves. Afterwards these were polished with glass and diamond knifes at the ultramicrotom (Ultracut, Rückert-Jung). After coal vaporization measurement took place in the scanning electron microscope (DSM 962, Zeiss). In the case of dry stored IOLs, the samples were sputtered with Au-Pd 20 nm and afterwards measurement was performed as described above. The measurement of the optical imaging quality was performed with correctly and inversely oriented IOLs according to the standard EN ISO 11979 -- 2 by means of a measuring system which works on the basis of the point spread function (PSF) and/or the modulation transfer function (MTF). From this the Strehl ratio was computed in each case. RESULTS: Utilizing a correlation of the electron microscopic investigation of the optics of different IOLs with their imaging quality (Strehl ratio), we were able to show that the optical design of the IOL has substantial influence on the imaging quality of an intraocular lens. In particular, with non-symmetrical designs of the optics (e. g., AR40 e; AMO) the orientation of an IOL in the eye is crucial; i. e., the Strehl ratio increased thereby from 0.68 to 0.87. CONCLUSIONS: The design of asymmetrical optics is crucial and much attention should be paid to the fact that the imaging quality can substantially be affected. A correct orientation of the lens within the eye is very important with these asymmetrical optics.

Algorithms↗

Elevated serum levels of N(epsilon)-carboxymethyl-lysine, an advanced glycation end product, are associated with proliferative diabetic retinopathy and macular oedema.

AIMS/HYPOTHESIS: Diabetic retinopathy is a frequent microvascular complication. In search of novel risk markers, we analysed the association between serum levels of the major advanced glycation end product N(epsilon)-carboxymethyl-lysine (CML) and prevalence of advanced stages of retinopathy in Type 2 diabetic patients without nephropathy. METHODS: We carried out a case-control study of Type 2 diabetic patients with and without advanced stages of diabetic retinopathy. Retinopathy and macular oedema were defined according to standard criteria. Serum levels of CML were estimated by means of a novel competition-based ELISA assay. RESULTS: Serum levels of CML were significantly different between age-matched controls (n=792; mean value +/- SD: 521+/-134 ng/ml), Type 2 diabetic patients without severe retinopathy (821+/-141 ng/ml; p<0.0001) and Type 2 diabetic patients with proliferative retinopathy (1182+/-346 ng/ml; p<0.0001). Levels of CML greater than 1000 ng/ml represented a 25-fold increase in risk of proliferative retinopathy. Receiver operating characteristics analysis revealed a CML threshold of 1087 ng/ml (100% sensitivity, 93% specificity) for clinically significant macular oedema. CONCLUSIONS/INTERPRETATION: High serum levels of CML were associated with advanced stages of retinopathy. Serum levels were shown to be a progressive risk marker, whereby a level of more than 1000 ng/ml induced a 25-fold increase in risk of proliferative retinopathy and clinically significant macular oedema. Our data suggest that serum levels of CML provide a novel risk marker for advanced stages of diabetic retinopathy in Type 2 diabetic patients.

Biomarkers↗

[Effect of growth factors on the differentiation of porcine lens epithelial cells].

BACKGROUND: Besides cell proliferation, transdifferentiation of lens epithelial cells (LECs) to myofibroblasts is one of the mechanisms of secondary cataract formation. This process is characterized by increased expression of alpha-smooth muscle actin (alpha-SMA). This study investigated the influence of bFGF, TGF-beta2, EGF and IGF-1 on the expression of alpha-SMA in porcine LECs. MATERIALS AND METHODS: Porcine LECs were cultured for 7 days in serum-free medium without or with 1 to 50 ng/ml bFGF, TGF-beta2, EGF or IGF-I. Alpha-SMA was detected immunocytochemically with a mouse monoclonal antibody, and the relative numbers of alpha-SMA-positive cells were calculated. Statistical analysis was performed using Student's unpaired t-test. RESULTS: The ratio of alpha-SMA-positive cells cultured for 7 days in serum-free medium was 36 +/- 11.9 % (mean +/- SD). BFGF significantly reduced this ratio in a dose-dependent manner to 11.2 +/- 7.3 % at a concentration of 50 ng/ml (p < 0.0001). EGF reduced the ratio significantly to 25.1 +/- 15.7 % (p = 0.05) when 50 ng/ml were applied. IGF-1 (10 ng/ml) reduced the relative numbers of transdifferentiated cells to 16.8 +/- 5.8 %, but the reduction was not statistically significant (p = 0.0787). TGF-beta2 (50 ng/ml) slightly increased the relative number of alpha-SMA-positive cells to 44.2 +/- 13.8 %. However, this increase was not significant (p = 0.1202) during a culture period of 7 days. CONCLUSIONS: BFGF and EGF significantly reduced the expression of alpha-SMA by LECs while TGF-beta and IGF-1 had no statistically significant effect. These results suggest that bFGF and EGF do not primarily induce secondary cataract formation by the mechanism of cell transdifferentiation.

Actins↗

[Spontaneous dislocation of intraocular lens with capsule as a late complication of cataract surgery in patients with pseudoexfoliation syndrome --five case reports].

PURPOSE: Pseudoexfoliation syndrome (PEX) is associated with zonular weakness and a higher frequency of intraoperative complications during cataract surgery, including rupture of the posterior lens capsule, zonular dialysis and a rise of intraocular pressure occurring postoperatively. Delayed dislocation of an IOL is a rarely reported phenomenon. PATIENTS: Within one year, late dislocation of the lens capsule with the in the bag fixated IOL was observed following cataract surgery in five patients (67, 74, 79, 90 and 92 years old) with pseudoexfoliation syndrome. RESULTS: All patients had an uneventful in the bag implantation of the IOL 6 (three patients), 3 and 11 years ago, respectively. Postoperatively occurring secondary cataract was treated by a YAG-capsulotomy in four cases. No patient had any other predisposing factors that would lead to zonular weakness besides the pseudoexfoliation syndrome. The dislocation of the IOL and capsule occurred spontaneously. In one patient with preexisting glaucoma, the dislocation was followed by an increase of intraocular pressure. All cases were successfully treated with IOL explantation, anterior vitrectomy and placement of an anterior chamber IOL. CONCLUSION: Patients with pseudoexfoliation syndrome undergoing cataract surgery may be at risk not only for intraoperative complications but also for delayed spontaneous dislocation of the IOL and capsule. This possible complication should be considered in surgical planning for patients with pseudoexfoliation syndrome. In these patients it may be better to implant the IOL in the ciliary sulcus.

Aged↗

[Cataract surgery with implantation of toric silicone lenses for severe astigmatism after keratoplasty].

BACKGROUND: The treatment of high astigmatism after keratoplasty is often not possible with glasses or refractive corneal surgery, particularly in patients with anisometropia and contact lens incompatibility. METHODS: In 3 patients with cataract and high astigmatism after penetrating keratoplasty, phacoemulsification was performed via a 4 mm sclerocorneal tunnel incision. A toric silicone lens with Z-haptic was implanted in the bag (Type MS 6116 TU, Dr. Schmidt). All patients had high anisometropia and contact lens incompatibility. The follow-up was ten weeks, uncorrected and corrected visual acuity, corneal and total astigmatism were evaluated. RESULTS: A 68-year-old female presented with corneal astigmatism of 10 dpt. Keratoplasty was performed two years earlier. After implantation of a toric lens (+ 22.5 + 11.0 dpt.) uncorrected visual acuity increased from 1/50 to 20/40, corrected visual acuity increased from 20/30 to 20/25. A 78-year-old male presented with irregular corneal astigmatism of 6.5 dpt. Keratoplasty was performed 25 years previously. Due to high myopia (corneal radii 5.3/5.9 mm), implantation of a toric lens (- 3.0 + 7.0 dpt.) in the bag was combined with implantation of a spheric lens (- 6.0 dpt., Type MS 614, Dr. Schmidt) in the sulcus. Uncorrected visual acuity increased from light perception to 1/20, corrected visual acuity increased to 1/10. An 84-year-old female presented with irregular corneal astigmatism of 8.6 dpt. Keratoplasty was performed two years earlier. After implantation of a toric lens (+ 16.0 + 11.0 dpt.) uncorrected visual acuity increased to 20/50, corrected visual acuity increased from 20/100 to 20/25. During the follow-up all implanted lenses were well-centered and no significant IOL rotation was observed. CONCLUSION: Implantation of foldable toric silicone lenses during cataract surgery may improve considerably the uncorrected visual acuity by reducing the total astigmatism in patients with high astigmatism after keratoplasty. Preoperatively, a reliable keratometry is important.

Aged↗

[Comparison of the optical coherence method (Zeiss IOL-Master) with two ultrasonographic biometric methods for the calculation of posterior chamber intraocular lenses after phacoemulsification as part of clinical routine].

BACKGROUND: The aim of this work was to investigate the accuracy of prediction of three different biometric methods for the calculation of posterior chamber intraocular lenses. METHODS: In 59 consecutive patients who underwent extracapsular cataract-extraction with posterior chamber intraocular lens implantation, we compared the refractive results at the first day (D1) and 6 weeks (W6) after surgery with the calculated refraction of three biometric methods: the Carl Zeiss "IOL-Master 99" (IOLM), the Biovision "Echograph Class 1 - Type B" (BIOV) and the Allergan Humphrey "Ultrasonic Biometer Mod. 820" (AHUB). For statistical calculation box-plots, the Wilcoxon signed-rank test and linear regression analysis were used. RESULTS: In all patients the mean of the postoperative refraction was - 0.07 D (SD: 1.41) at day 1 and 0.12 D (SD: 1.18) at week 6. Compared to the postoperative refraction at week 6, the calculated refractive values were higher in all three measuring devices: IOLM: + 0.28 D (SD: 0.67), BIOV: + 0.60 D (SD: 0.88), AHUB: + 0.26 D (SD: 0.92). There were no statistically significant differences between IOLM and BIOV, or respectively, AHUB and BIOV (p < 0.0001), but a significant difference was found between IOLM and AHUB, (p = 0.906). To adjust for systematic differences of the agreement, one can calculate the postoperative refraction at week 6 (REF6) from IOLM by using the linear regression formula: REF6 = 1.1 x IOLM + 0.3. CONCLUSION: A comparison between the three biometric methods and the refractive results at day 1 and week 6 after cataract surgery with implantation of a posterior chamber intraocular lens showed that the calculated mean values obtained from the three biometric methods are higher than the real postoperative refraction. Calculations using the Zeiss IOL-Master and the Allergan Humphrey Ultrasonic Biometer are closer to the patient's postoperative refraction than calculations using the Biovision Echograph.

Aged↗

Octreotide prevents growth factor-induced proliferation of bovine retinal endothelial cells under hypoxia.

Ocular diseases such as proliferative diabetic retinopathy are the major cause of blindness in industrialized countries. The main pathologic features of these diseases are hypoxia and overproduction of growth factors resulting in pathologic proliferation of endothelial cells and new vessel formation. Particularly, hypoxia and growth factors, such as VEGF, IGF-1, bFGF and TGF beta(2), show a complex interaction in the onset and progression of the diseases. Therefore, to date, most therapeutic strategies for proliferative retinopathies have targeted proliferation of endothelial cells evoked by growth factors. Recently, a synthetic analog of somatostatin, octreotide, has been shown to inhibit the proliferation of various cells in vitro, including endothelial cells. In this study, we have investigated the proliferative response of bovine retinal endothelial cells (BREC) to growth factors under hypoxic conditions and the modulation by octreotide. We found a dose-dependent increase of cell proliferation with VEGF, IGF-1 and bFGF, and inhibition of hypoxia-induced cell proliferation with TGF beta(2). Moreover, growth factor-induced, but not hypoxia-induced, cell proliferation was attenuated in the presence of octreotide. In contrast, TGF beta(2) abolished hypoxia-induced BREC proliferation. Similar to octreotide BIM23027, a somatastatin receptor subtype 2 (SSTR2) receptor agonist was able to attenuate the growth factor-induced proliferation of BREC expressing mRNA and protein for SSTR2. Therefore, we postulate that octreotide exerts its effects mainly through binding to the SSTR2. Taken together, our findings point to octreotide as a promising candidate for the treatment of eye disorders involving growth factor-dependent proliferation of endothelial cells.

Animals↗

Low content of the natural ocular anti-angiogenic agent pigment epithelium-derived factor (PEDF) in aqueous humor predicts progression of diabetic retinopathy.

AIMS/HYPOTHESIS: Retinopathy is the most common microvascular complication of diabetes. Our aim was to address the predictive value of pro-angiogenic and anti-angiogenic markers for progression of retinopathy. METHODS: Aqueous humor was collected at cataract surgery from 32 diabetic patients who had no or very mild retinopathy (ETDRS stage </=20) and 33 normoglycaemic control subjects. Content of pro-angiogenic vascular endothelial growth factor and angiogenic inhibitor pigment epithelium-derived factor were determined. ANGIOGENIC activity was quantified by measuring its effect on the migration of capillary endothelial cells. The predictive value of the initial level of these markers for progression of retinopathy was studied by following the probands for a maximum of 75 months. RESULTS: In the aqueous fluid content of vascular endothelial growth factor was increased in diabetic patients (mean values 492 versus 292 pg/ml; p=0.0052), and pigment epithelium-derived factor values were decreased (mean values 1740 versus 3680 ng/ml; p=0.0058) compared to control subjects. Of the diabetic patients ten progressed during follow-up (ETDRS stage >47B). This subgroup showed lower pigment epithelium-derived factor content when compared to non-progressors and control subjects. Migratory activity in samples of patients from the control group and in diabetic patients without progression was generally inhibitory due to pigment epithelium-derived factor. Inhibition was blocked by neutralizing antibodies to pigment epithelium-derived factor. In diabetic patients initial angiogenic activity was higher in those who later developed retinopathy (vs. controls p=0.00005; vs. no progressors p=0.0003). Both pigment epithelium-derived factor and migratory response predicted progression. CONCLUSION/INTERPRETATION: Pigment epithelium-derived factor is an important negative regulator of angiogenic activity of aqueous humor. Its content in the aqueous humor of diabetic patients strongly predicts who among them will develop progression of retinopathy.

Aged↗

Proliferative diabetic retinopathy is associated with a low level of the natural ocular anti-angiogenic agent pigment epithelium-derived factor (PEDF) in aqueous humor. a pilot study.

Retinopathy is the most common microvascular diabetes complication and represents a major threat to the eyesight. The aim of this study was to address the role of pro- and anti-angiogenic molecules in diabetic retinopathy in the aqueous humor of the eye. Aqueous humor was collected at cataract surgery from 19 diabetic patients and from 13 age- and sex-matched normoglycemic controls. Levels of pro-angiogenic vascular endothelial growth factor (VEGF) and angiogenic inhibitor pigment epithelium-derived factor (PEDF) were determined. Angiogenic activity of the aqueous humor was quantified by measuring its effect on the migration of capillary endothelial cells. In the aqueous fluid, VEGF levels were increased in diabetics (mean values: 501 vs. 367 pg/ml; p = 0.05), compared to controls. PEDF was found to be decreased in diabetics (mean values: 2080 vs. 5780 ng/ml; p = 0.04) compared to controls. In seven diabetic patients with proliferative retinopathy, the most profound finding was a significant decrease of the PEDF level (mean value: 237 ng/ml), whereas VEGF levels were comparable to diabetic patients without proliferation (mean value: 3153; p = 0.003). Angiogenic activity in samples of patients from the control group was generally inhibitory due to PEDF, and inhibition was blocked by neutralizing antibodies to PEDF. Likewise, in diabetics without proliferation, angiogenic activity was also blocked by antibodies to PEDF. We will demonstrate here that the level of the natural ocular anti-angiogenic agent PEDF is inversely associated with proliferative retinopathy. PEDF is an important negative regulator of angiogenic activity of aqueous humor. Our data may have implications for the development of novel regimens for diabetic retinopathy.

Aged↗

[Intracanalicular trabeculostomy with the Er:YAG laser].

PURPOSE: To develop a new ab externo technique for glaucoma trabecular surgery using the infrared Er:YAG laser radiation (2.9 micrometer) guided into Schlemm's canal by an optical fiber. MATERIAL AND METHODS: In order to create a drainage canal to the anterior chamber, a quartz fiber (core diameter: 100 micrometer) coupled to an Er:YAG laser was shielded by a metal canula (diameter: 280 micrometer) bent in conformance to the curvature of Schlemm's canal. A 45 degrees -mirror enabled the laser radiation to exit the canula perpendicular to the fiber axis. The complete surgery device was tested on agar medium and enucleated human eyes. RESULTS: Using the unshielded quartz fiber, eight pulses of 8 mJ (frequency: 7 Hz, pulse duration: 150 microseconds) were sufficient to perforate the trabecular meshwork of the human eye. Histology showed a rippled canal with 50 micrometer average diameter and a surrounding necrosis zone of 15-35 micrometer. The complete device could be easily inserted into Schlemm's canal similar to the classic trabeculostomy probe and a conical-shaped canal with a length of 2-3 mm could be created in agar medium within a few seconds. CONCLUSIONS: Initial experience in an experimental set-up show the ab externo creation of a draining canal between Schlemm's canal and the anterior chamber with only minimal irritation of the surrounding tissue. Further refinements of the laser parameters and the biomechanical set-up resulted in a new hand-held device with improved function. The Er:YAG laser intracanalicular trabeculostomy could become a new ab externo technique for minimal invasive therapy of open angle glaucoma.

Equipment Design↗

[Endophthalmitis following cataract surgery].

BACKGROUND: Infectious endophthalmitis is a serious complication following cataract surgery, since it often induces a substantial reduction of visual acuity. PATIENTS AND METHODS: We retrospectively evaluated the clinical data of 53 patients with endophthalmitis following cataract surgery who were treated at the department of ophthalmology of the University Hospital in Ulm between 1995 and May 2001. Of these patients, 50 had been referred. Clinical presentation, infecting organism, treatment and visual outcome were analysed with a followup ranging from 2 weeks up to 42 months (median: 6 months). RESULTS: In 52 patients endophthalmitis was preceeded by cataract extraction and IOL implantation, in one case by secondary IOL implantation. Confirmed microbiologic growth was demonstrated from intraocular specimens in 26 out of 41 operated eyes (63%), the most frequent causative organisms were coagulase-negative Staphylococci (50%). All isolated bacteria were sensitive to a combination of the antibiotics vancomycin and amikacin or vancomycin and ceftazidime. 13 patients were treated with intravenous antibiotic therapy alone. In 46% of patients, who were initially treated with intraocular antibiotic injections alone, required further therapeutic intervention for recurrent infection. Only 7.7% of the patients who initially underwent intraocular antibiotic injections combined with IOL removal or pars plana vitrectomy with or without IOL removal, required further surgical intervention. Initial visual acuity was hand movements (median) only but improved during follow-up to 0.2 (median). CONCLUSIONS: In this series all tested bacteria were susceptible to the combination of vancomycin with either amikacin or ceftazidime. Aggressive initial treatment including IOL removal may be associated with a lower frequency of recurrent disease.

Amikacin↗