PubMed HealthSearch

Biomedical subjects

G Knichwitz

Publications and source records attributed to G Knichwitz.

4 recordsLinked to original sources

Improved PCO2 measurement in six standard blood gas analysers using a phosphate-buffered solution for gastric tonometry.

The measurement of gastric intramucosal pH serves as a non-invasive technique for early detection of gastrointestinal ischaemia in critically ill patients. The method is based on the determination of the partial pressure of carbon dioxide in a 0.9% saline solution using a standard blood gas analyser. However, the use of standard blood gas analysers leads to an underestimation of carbon dioxide partial pressure in saline. Instrumental biases of six blood gas analysers were investigated using either a saline or a phosphate-buffered solution. Both test solutions were equilibrated with five defined carbon dioxide concentrations. Each blood gas analyser underestimated this defined partial pressure of carbon dioxide with a bias between -3.7% and -57.5% if saline was used. The phosphate-buffered solution considerably improved instrumental precision, resulting in biases between +2.7% and -17.6% Thus, a phosphate-buffered solution increases the accuracy of gastric intramucosal pH measurement.

Blood Gas Analysis

Cardiopulmonary effects of constant-flow ventilation in experimental myocardial ischaemia.

The cardiopulmonary effects of constant-flow ventilation were investigated in dogs with normal heart function (control-phase, n = 14) and after development of acute myocardial ischaemia (ischaemia phase, n = 14). Heated, humidified and oxygen-enriched air was continuously delivered with an inspiratory flow rate of 1.21.kg-1.min-1 via two catheters positioned within each mainstem bronchus. Continuous positive pressure ventilation with a positive end-expiratory pressure of 0.5 kPa (5 cmH2O) was used as a reference. During control, neither continuous positive pressure ventilation nor constant-flow ventilation showed impairment of cardiopulmonary performance. Oxygenation and CO2 removal were more efficiently achieved by continuous positive pressure ventilation (P less than or equal to 0.05). Acute myocardial ischaemia was induced by occlusion of the left anterior descending (LAD) coronary artery; measurements during the ischaemia phase were performed 60 min following LAD occlusion. Myocardial ischaemia resulted in moderate changes of cardiac output, left ventricular end-diastolic pressure and dP/dtmax. Both modes of ventilation were well tolerated in the ischaemia phase, and cardiovascular performance revealed no significant differences between continuous positive pressure ventilation and constant-flow ventilation. Haemodynamic parameters could be more precisely assessed during constant-flow ventilation. Oxygenation deteriorated, but hypoxaemia did not occur in any animal and CO2 elimination remained unchanged. It is concluded that 'non-conventional' ventilation by continuous intrabronchial gas flow maintains adequate gas exchange with no adverse effects on haemodynamics in dogs with acute myocardial ischaemia. Constant-flow ventilation may be advantageous in the experimental setting to study cardiac function without cyclic heart-lung interaction due to airway pressure alterations.

Animals

Constant-flow ventilation during experimental left ventricular failure.

The efficacy of constant-flow ventilation (CFV) was investigated in dogs with normal heart function (control phase, n = 8) and after development of left ventricular failure (LVF phase, n = 8). Heated, humidified and oxygen-enriched air (inspired oxygen fraction (Fio2) = 0.4) was continuously delivered via two catheters positioned within each mainstem bronchus at two flow rates (1.2 and 1.6 l/kg/min). Conventional mechanical ventilation (CMV) with positive end-expiratory pressure (PEEP) of 0.5 kPa was used as reference ventilation. During control, neither CMV with PEEP nor CFV revealed severe impairment of cardiopulmonary performance. Alveolo-arterial PO2 difference (P(A-a)O2) increased significantly during CFV1.2 and CFV1.6, indicating a higher degree of ventilation-perfusion (VA/Q) inhomogeneity. Acute left ventricular failure (LVF) was induced by proximal occlusion of the left anterior descending (LAD) coronary artery. Cardiac output (CO), maximum velocity of pressure development (dP/dtmax) and mixed venous PO2 decreased (P less than or equal to 0.05), whereas left ventricular end-diastolic pressure (LVEDP) and pulmonary capillary wedge pressure (PCWP) increased (P less than or equal to 0.05). Extravascular lung water (EVLW), as determined by thermal-dye technique, increased from 10.1 ml/kg to 20.9 ml/kg (P less than or equal to 0.01). Oxygenation, but not CO2 elimination, deteriorated in the LVF phase. There were no haemodynamic differences between CMV with PEEP and CFV1.2, but cardiopulmonary performance deteriorated with CFV1.6. Gas exchange was significantly more impaired during CFV1.2 and CFV1.6 due to increased VA/Q mismatching. However, there were no significant differences for P(A-a)O2 values between CFVControl and CFVLVF.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals