[Color-coded duplex sonography in primary diagnosis, monitoring and prognostic evaluation of fibrinolytic and conservative therapy of thrombophlebitis].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G Kreymann.
Explore the source record for details and available documents.
Between November 1988 and February 1990, a total of 180 patients (76 men and 104 women; mean age 59 [17-79] years), suspected of having sustained a deep-vein or pelvic thrombosis were examined by colour Doppler ultrasound, the results being compared with those obtained by conventional phlebography. For 154 phlebographically confirmed acute venous thromboses (demonstrated by colour Doppler ultrasound in 153), four older thromboses (colour Doppler ultrasound: 7), and 22 without significant venous disease (colour Doppler ultrasound: 20), the specificity for colour Doppler ultrasound was 99%, its sensitivity 94%. In 49 patients with confirmed venous thrombosis thrombolytic treatment was started with 250,000 IU urokinase, followed by 62,500 IU hourly, the results being assessed by colour Doppler ultrasound and phlebography. This gave a specificity, compared with phlebography, of 99%, and a sensitivity of 97%. These data indicate that, in the diagnosis of venous thrombosis of the legs, colour Doppler ultrasound noninvasively provides information at least as reliable as phlebography. It may even be superior to phlebography in the demonstration of residual flow in partly thrombosed veins.
We compared the effects of various dialysate composition on pulmonary and transdialyzer gas exchange in patients during hemodialysis. Under acetate hemodialysis there was a permanent loss of CO2 (45-68 ml/min) into the dialysate resulting in a significant decrease of arterial pO2, which can be explained by a reduced alveolar ventilation. The pulmonary oxygen uptake increased up to +20% during treatment, reflecting rising energy metabolism and possibly increased cardiopulmonary instability. Using different concentrates for bicarbonatehemodialysis we saw a moderate to clinical relevant uptake of CO2 (40-60 ml/min) from the dialysate into the blood of the patients, cause the pCO2 in the dialysate varied between 45 and 115 mmHg. Bicarbonate hemodialysis with high pCO2-levels in the dialysate led to hyperventilation and markedly increased oxygen consumption. In critically ill hemodialysis patients the pathophysiologic effects on pulmonary gas exchange of either acetatehemodialysis and bicarbonatehemodialysis with high pCO2 can explain the higher incidence of severe complications.
To examine the cellular mechanism responsible for impaired insulin action in ageing, we determined various in-vitro parameters involved in the pathogenesis of insulin resistance, i.e. basal and insulin-stimulated [14C]3-O-methylglucose transport (3OMG), 125I-labelled insulin binding, activation of insulin receptor kinase (IRKA) in intact cells, and number and subcellular distribution of glucose transporters in subcellular membrane fractions of adipocytes from 6- (FR-6) and 24- (FR-24) month-old Fischer rats. Ageing had no effect on basal 3OMG (12 +/- 4 vs 13 +/- 3 fmol/5 x 10(4) cells, means +/- S.E.M.); in contrast, in FR-24 rats insulin-stimulated 3OMG was markedly decreased by 43% when compared with that in FR-6 rats (158 +/- 14 vs 90 +/- 8 fmol/5 x 10(4) cells; P less than 0.01). Insulin binding to adipocytes from FR-6 rats was 2.40 +/- 0.38% compared with 2.28 +/- 0.47% in FR-24 (P not significant). Moreover, ageing had no significant effect on IRKA, as determined by insulin-stimulated (0, 1, 4 and 500 ng insulin/ml) 32P-incorporation into histone 2B. In subcellular membrane fractions, low density microsomes and plasma membranes, glucose transporter numbers were determined using [3H]cytochalasin B binding and immunodetection using an antiserum against the C-terminal peptide of the hepatoma-G2-glucose transporter. Cytochalasin B binding revealed that in the basal state the intracellular pool of glucose transporters was depleted in FR-24 by about 39% compared with low density microsomes from FR-6: (48.6 +/- 7.2 vs 29.8 +/- 5.5 pmol/mg membrane protein; P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
A new device for the continuous monitoring of oxygen uptake and carbon dioxide delivery is presented, which is based on a continuous expired gas analysis using a paramagnetic oxygen and an infrared-absorption carbon dioxide sensor. To validate the results, data of measured oxygen uptake and cardiac output calculated by the Fick principle were compared to synchronous thermodilution measurements at rest and during exercise. Measurements were performed at rest on 18 patients, additionally 13 of the patients were exercised with either 25 W or 50 W workload. The results indicate, for both measurement series, a significant correlation (r greater than 0.95, p less than 0.001) and exemplify that the measurement of oxygen uptake by expired gas analysis permits a precise analysis of the cardiovascular transport function during exercise.
The noninvasive determination of the respiratory gas exchange (measurement of oxygen uptake and carbon dioxide delivery) permits the calculation of cardiac output by Fick principle and of the actual energy requirement of the patient (indirect calorimetry). A system is presented for the continuous measurement of oxygen uptake and carbon dioxide delivery, that bases on simple components, which are available on most intensive care units. The methodical problems are discussed and the improvement of the signal of the oxygen sensor by digital signal processing is described. Clinical measurements on 16 patients are presented, whose metabolic rate early after extracorporal circulation was measured. The results reveal, that 4.4 hours after ECC the metabolic rate is close to the calculated basic metabolic rate. They demonstrate the importance of indirect calorimetry as a future bedside monitoring routine.